ARMY A-A-52499 A-2009 LEAD ELECTRICAL (STORAGE BATTERY)《(蓄电池)电阴线》.pdf
《ARMY A-A-52499 A-2009 LEAD ELECTRICAL (STORAGE BATTERY)《(蓄电池)电阴线》.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52499 A-2009 LEAD ELECTRICAL (STORAGE BATTERY)《(蓄电池)电阴线》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to U.S. Army Tank-automotive and Armaments Command, ATTN: RDTA-EN/STND/TRANS, MS# 268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact information can change, you may
2、want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 6140 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND A-A-52499A August 18, 2009 SUPERSEDING A-A-52499 1 August 1994 COMMERC
3、IAL ITEM DESCRIPTION LEAD, ELECTRICAL (STORAGE BATTERY) The General Services Administration has authorized the use of this commercial item description (CID) for all federal agencies. 1. SCOPE. This CID covers electrical leads for storage batteries. Each lead consists of a round, insulated, single co
4、nductor cable and two watersealed crimp type solderless terminals. 2. SALIENT CHARACTERISTICS 2.1 Materia1s. The materials shall be as specified herein and in referenced documents. The use of recovered material made in compliance with regulatory requirements is acceptable providing all the requireme
5、nts of the CID are met (see 5.5). 2.1.1 Cables. The cable shall be of the unshielded insulated single conductor type consisting of the following: 2.1.1.1 Strands. The individual conductor strands shall be made of soft drawn and annealed tin coated solid copper wire. 2.1.1.2 Insulation. The insulatio
6、n material shall be such as to meet the construction and performance requirements specified herein. 2.1.1.3 Sheath. The sheath shall be made of a material which meets the performance requirements of this CID. A polychloroprene based material is preferred. Provided by IHSNot for ResaleNo reproduction
7、 or networking permitted without license from IHS-,-,-A-A-52499A 2 2.1.1.4 Braid. The braid shall be made of cloth/glass. It shall be free from any substance that may have a deteriorating effect on the insulation or on the sheath. Further, the braid shall not be adversely affected by the compounding
8、 ingredients of the insulation or sheath. 2.1.1.5 Separator. The separator shall be made of a fungus resistant material which shall be free from any substance that would have a deteriorating effect on the insulation or conductor. Further, the separator itself shall not be adversely affected by compo
9、unding ingredients used in the cable construction or process. 2.1.2 Terminals. Terminals shall be made of materials as specified in drawing 7056700. 2.2 Design and construction. Leads shall be designed and constructed as specified herein and in applicable referenced documents (see figure 1). The cab
10、le shall consist of a sheath, insulation, open braid, separator and conductor. As an optional construction, the sheath and insulation may be combined (see figure 2). PIN Number A Length 0.25 Stud Hole Size 0.010 Conductor Size (AWG) Cable Diameter 0.010 B C Reference Terminal Number Part (see note 2
11、) A52499-1 14.00 .210 8 0.360 0.22 0.38 7056712 A52499-2 A52499-3 A52499-4 6.00 9.50 12.50 .395 2 0.610 0.44 0.81 7056730 A52499-5 8.25 A52499-6 9.25 A52499-7 10.50 .395 1/0 .672 .44 .81 7056732 A52499-8 17.25 A52499-9 18.25 FIGURE 1. Electrical lead design, construction and part numbers. Provided b
12、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52499A 3 PIN Number A Length 0.25 Stud Hole Size 0.010 Conductor Size (AWG) Cable Diameter 0.010 B C Reference Terminal Part Number (see note 2) A52499-10 24.75 A52499-11 27.75 A52499-12 29.75 A52499-13 40.00
13、 .395 1/0 .672 .44 .81 7056732 A52499-14 42.00 A52499-15 12.75 A52499-16 14.25 A52499-17 A52499-18 A52499-19 A52499-20 A52499-21 A52499-22 15.25 22.75 8.00 17.00 24.00 34.00 .395 2/0 0.730 0.44 0.81 7056700.1 NOTES: 1. Dimensions are in inches. Unless otherwise specified, tolerances are 0.03. 2. Ref
14、erenced terminal part numbers are as shown in drawing 7056700. FIGURE 1. Electrical lead design, construction, and part numbers - Continued. 2.2.1 Cables. Cables shall be designed and constructed as shown in figure 2. NOTE: Outside diameters of cables are listed in figure 1. FIGURE 2. Cable design a
15、nd construction. 2.2.1.1 Conductor construction. The conductors shall consist of individual strands. The conductors shall be continuous throughout their length except joints in individual strands shall be made by butt brazing or twisting strands together. Individual joints shall occur no closer toge
16、ther Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52499A 4 than 1 foot. In no case shall the whole conductor be spliced at one point. Stranding of the conductor shall be left or right hand lay and, at the option of the contractor, may be bunch
17、ed concentric, or rope lay. The cross-section of conductors shall conform to table I. 2.2.1.2 Separator. A mechanical or chemical separator shall be applied between the conductor and the insulation to prevent deterioration of the insulating compound and to provide for its easy removal using commerci
18、al stripping procedures. TABLE I. Constructional requirements for conductors. Conductor size (AWG) Minimum area (Circular mils) Minimum number of strands Maximum diameter of stranded conductors (mils) 8 16,180 133 176.0 2 65,495 663 345.0 1/0 101,235 1,033 432.0 2/0 130,990 1,327 490.0 2.2.1.3 Insul
19、ation. The insulating compound shall form a close fit over the separator without adherence. As applied, the compound shall be seamless and shall be free of any visible foreign material. 2.2.2 Terminals. Terminals shall be designed and constructed as shown in SAE J561 and in accordance with the appli
20、cable referenced item part number specified in Drawing 7056700 (see figure 1). 2.3 Cable performance. 2.3.1 Insulation flaws. Insulated conductors and finished cables shall be furnished free of insulation flaws. Flaws which are revealed after exposure to the voltage in table II shall be removed. TAB
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52499A2009LEADELECTRICALSTORAGEBATTERY 蓄电池 电阴线 PDF

链接地址:http://www.mydoc123.com/p-440047.html