ANSI Z80.28-2017 Ophthalmics C Methods of Reporting Optical Aberrations of Eyes (VC)《眼科.眼的光学象差报告用方法》.pdf
《ANSI Z80.28-2017 Ophthalmics C Methods of Reporting Optical Aberrations of Eyes (VC)《眼科.眼的光学象差报告用方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI Z80.28-2017 Ophthalmics C Methods of Reporting Optical Aberrations of Eyes (VC)《眼科.眼的光学象差报告用方法》.pdf(45页珍藏版)》请在麦多课文档分享上搜索。
1、American National Standardfor Ophthalmics Methods of ReportingOptical Aberrations of EyesANSI Z80.28-2017ANSIZ80.28-2017ANSIZ80.28-2017Revision ofANSI Z80.28-2010American National Standardfor Ophthalmics Methods for ReportingOptical Aberrations of EyesSecretariatThe Vision CouncilApproved March 27,
2、2017Published August 21, 2017American National Standards Institute, Inc.Approval of an American National Standard requires review by ANSI that therequirements for due process, consensus, and other criteria for approval havebeen met by the standards developer.Consensus is established when, in the jud
3、gement of the ANSI Board ofStandards Review, substantial agreement has been reached by directly andmaterially affected interests. Substantial agreement means much more thana simple majority, but not necessarily unanimity. Consensus requires that allviews and objections be considered, and that a conc
4、erted effort be madetowards their resolution.The use of American National Standards is completely voluntary; theirexistence does not in any respect preclude anyone, whether he has approvedthe standards or not, from manufacturing, marketing, purchasing, or usingproducts, processes, or procedures not
5、conforming to the standards.The American National Standards Institute does not develop standards andwill in no circumstances give an interpretation of any American NationalStandard. Moreover, no person shall have the right or authority to issue aninterpretation of an American National Standard in th
6、e name of the AmericanNational Standards Institute. Requests for interpretations should beaddressed to the secretariat or sponsor whose name appears on the titlepage of this standard.CAUTION NOTICE: This American National Standard may be revised orwithdrawn at any time. The procedures of the America
7、n National StandardsInstitute require that action be taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of American National Standards mayreceive current information on all standards by calling or writing the AmericanNational Standards Institute.American National StandardPu
8、blished byThe Vision Council225 Reinekers LaneSuite 700Alexandria, VA 22314Copyright 2017 by The Vision CouncilAll rights reserved.No part of this publication may be reproduced in anyform, in an electronic retrieval system or otherwise,without prior written permission of the publisher.Developed byTh
9、e Accredited Committee Z80 for Ophthalmic Standards -The Vision CouncilZ80 Secretariat225 Reinekers LaneSuite 700Alexandria, VA 22314iContentsPageForeword ii1 Scope . 12 Normative References 13 Symbols and Definitions. 24 Coordinate system 65 Representation of wavefront data. 75.1 Representation of
10、wavefront data with the use ofZernike polynomial function coefficients. 75.2 Representation of wavefront data in the form ofwavefront gradient fields of wavefront error function values 105.3 Gradient fit error . 116 Presentation of data representing the aberrations of the human eye. 126.1 General. 1
11、26.2 Aberration data presented in the form ofnormalized Zernike coefficients 126.3 Aberration data presented in the form of normalizedZernike coefficients given in magnitude/axis form 136.4 Aberration data presented in the form of topographical maps 146.5 Presentation of pooled aberration data 16Tab
12、les1 Symbols 22 Common names of Zernike polynomial functions. 83 Common names of Zernike polynomial functions. 10Figure1 Ophthalmic coordinate system . 6AnnexesA Methods of generating Zernike coefficients 18B Conversion of Zernike coefficients to account for differingaperture sizes, decentration and
13、 coordinate system rotation. 21C Conversion between Zernike coefficients represented indifferent systems of notation. 31D Computer algorithm to generate partial derivative weighing matricesfor un-normalized Zernike polynomial functions. 33E Table of normalized Zernike polynomial functions(through 6t
14、h radial order) 35F Bibliography 37iiForeword (This foreword is not part of American National Standard ANSI Z80.28-2017.)This American National Standard addresses the communication of aberrations of theeye. With the dramatic increase in applications associated with aberrations, it is im-portant to h
15、ave uniform methods for reporting data so that it is understandable acrossapplications.ANSI Z80.28-2017 was adapted by a group of experts within the ANSI Instrumentsand Low Vision Devices Subcommittee under the chair of William L. Brown, O.D.,Ph.D. It is a performance standard.The major change made
16、in this edition of the standard is a clarification of 5.2 that 1)changes the term “wavefront gradient fields“ to “wavefront ray deflection“, and 2)places the emphasis of the clause on describing the direction of propagation of raysthat are the normals to the wavefront error surface being measured.Su
17、ggestions for improvement of this standard will be welcome. They should be sentto the Vision Council, 225 Reinekers Lane, Suite 700, Alexandria, VA 22314.This standard was processed and approved for submittal to ANSI by the AccreditedStandards Committee on Ophthalmic Optics, Z80. Committee approval
18、of this stan-dard does not necessarily imply that all committee members voted for its approval. Atthe time of approval of this standard, the Z80 Committee consisted of the followingmembers:Thomas White, M.D., ChairQuido Cappelli, Vice-ChairWilliam Benjamin, SecretaryMichael Vitale, SecretariatOrgani
19、zation Represented Name of RepresentativeAbbott Medical Optics. Leonard BormannAdvance Medical Technologies Association Michael PflegerAmerican Academy of Ophthalmology . Thomas C. WhiteAmerican Academy of Optometry. David S. LoshinAmerican Ceramic Society . Lyle RubinAmerican Glaucoma Society Steve
20、n GeddeAmerican Optometric Association Karl CitekAmerican Society of Cataract and Refractive Surgery . Stephen KlyceContact Lens Institute. Stan RogaskiContact Lens Manufacturers Association . Martin DalsingDepartment of Veterans Affairs John TownsendFederated Cornea Societies. Michael BelinFood and
21、 Drug Administration CDRH/Division. Don CalogeroIndividual Ralph StoneNational Association of Optometrists and Opticians. Nick MiletiOpticians Association of America . Tom HicksOptical Laboratory Association. Steve SutherlinSunglass Association of America . Tibor GrossThe Vision Council Michael Vita
22、leUS ISO TC 172/SC7. Michael VitaleiiiThe Subcommittee on Instruments and Low Vision Devices, which modified thisAmerican National Standard, had the following members:William L. Brown, O.D., Ph.D., ChairMichael BelinDonald CalogeroCharles E. CampbellBruce DrumMatthew EverettThomas GarridoDavid Glass
23、erPriya JanakiramanTony KoStephen KlyceDavid LuceNick MiletiSharon MillerEli PeliMichael PflegerRobert RosenbergDexiu ShiJohn TownsendMichael VitaleThomas WhiteivAMERICAN NATIONAL STANDARD ANSI Z80.28-2017American National Standard for Ophthalmics Methods for Reporting Optical Aberrations of Eyes 1
24、1. Scope This standard specifies standardized methods for reporting the optical aberrations of eyes. 2. Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this American National Standard. At the time of publication, the edi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIZ80282017OPHTHALMICSCMETHODSOFREPORTINGOPTICALABERRATIONSOFEYESVC 眼科 光学 象差 报告 方法 PDF

链接地址:http://www.mydoc123.com/p-439696.html