ANSI Z80.21-2010 Ophthalmics - Instruments - General-Purpose Clinical Visual Acuity Charts (VC)《视力表》.pdf
《ANSI Z80.21-2010 Ophthalmics - Instruments - General-Purpose Clinical Visual Acuity Charts (VC)《视力表》.pdf》由会员分享,可在线阅读,更多相关《ANSI Z80.21-2010 Ophthalmics - Instruments - General-Purpose Clinical Visual Acuity Charts (VC)《视力表》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、American National Standardfor Ophthalmics Instruments General-Purpose ClinicalVisual Acuity ChartsANSI Z80.21-2010 (R2015)ANSI Z80.21-2010(R2015)ANSIZ80.21-2010 (R2015)Reaffirmation ofANSI Z80.21-2010American National Standardfor Ophthalmics Instruments General-Purpose ClinicalVisual Acuity ChartsSp
2、onsorThe Vision CouncilApproved May 27, 2010Reaffirmed April 23, 2015American National Standards Institute, Inc.Approval of an American National Standard requires review by ANSI that therequirements for due process, consensus, and other criteria for approval havebeen met by the standards developer.C
3、onsensus is established when, in the judgement of the ANSI Board ofStandards Review, substantial agreement has been reached by directly andmaterially affected interests. Substantial agreement means much more thana simple majority, but not necessarily unanimity. Consensus requires that allviews and o
4、bjections be considered, and that a concerted effort be madetowards their resolution.The use of American National Standards is completely voluntary; theirexistence does not in any respect preclude anyone, whether he has approvedthe standards or not, from manufacturing, marketing, purchasing, or usin
5、gproducts, processes, or procedures not conforming to the standards.The American National Standards Institute does not develop standards andwill in no circumstances give an interpretation of any American NationalStandard. Moreover, no person shall have the right or authority to issue aninterpretatio
6、n of an American National Standard in the name of the AmericanNational Standards Institute. Requests for interpretations should beaddressed to the secretariat or sponsor whose name appears on the titlepage of this standard.CAUTION NOTICE: This American National Standard may be revised orwithdrawn at
7、 any time. The procedures of the American National StandardsInstitute require that action be taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of American National Standards mayreceive current information on all standards by calling or writing the AmericanNational Standard
8、s Institute.American National StandardThe Vision Council225 Reinekers LaneSuite 700Alexandria, VA 22314Copyright 2015 by The Vision CouncilAll rights reserved.No part of this publication may be reproduced in anyform, in an electronic retrieval system or otherwise,without prior written permission of
9、the publisher.Printed in the United States of AmericaDeveloped byThe Accredited Committee Z80 for Ophthalmic StandardsThe Vision CouncilZ80 Secretariat225 Reinekers LaneSuite 700Alexandria, VA 22314Published byiContentsPageForeword ii1 Scope and purpose . 12 Normative references. 13 Clinical optotyp
10、e calibration . 24 System requirements 25 Application of standard 36 Marking . 4Table1 Progression of optotypes, in terms of gap size of the equivalent Landolt ring. 5Annexes A Methods of generating correlating optotypes. 6 B Bibliography . 10iiForeword (This foreword is not part of American Nationa
11、l Standard ANSI Z80.21-2010 (R2015).)This American National Standard addresses the optical design of optotypes used inclinical visual acuity measurement systems that use recognition of high-contrast op-totypes and that are designed for general use.ANSI Z80.21-2010 (R2015) was adapted by a group of e
12、xperts within the ANSI Oph-thalmic Instruments Subcommittee under the chairmanship of William L. Brown,O.D., Ph.D. It is a performance standard.There are no substantive changes in this document compared to the previous 2010edition.This standard contains two annexes. Annex A, which is normative, is c
13、onsidered partof this standard. Annex B, which is informative, is not considered part of this stan-dard.Suggestions for improvement of this standard will be welcome. They should be sentto the Vision Council, 225 Reinekers Lane, Suite 700, Alexandria, VA 22314.This standard was processed and approved
14、 for submittal to ANSI by the AccreditedStandards Committee on Ophthalmic Optics, Z80. Committee approval of this stan-dard does not necessarily imply that all committee members voted for its approval. Atthe time of approval of this standard, the Z80 Committee consisted of the followingmembers:Thoma
15、s White, M.D., ChairmanQuido Cappelli, Vice-ChairmanWilliam Benjamin, O.D., SecretaryJeff Endres, SecretariatOrganization Represented Name of RepresentativeAbbott Medical Optics. Leonard BorrmannAdvance Medical Technologies Association Michael PflegerAmerican Academy of Ophthalmology . Dr. Thomas Wh
16、iteAmerican Academy of Optometry. Dr. David LoshinAmerican Ceramic Society Lyle RubinAmerican Glaucoma Society . Dr. Steven GeddeAmerican Optometric Association . Dr. Karl CitekAmerican Society of Cataract and Refractive Ophthalmology Dr. Stephen KlyceContact Lens Institute. Stan RogaskiContact Lens
17、 Manufacturers Association . Quido CappelliDepartment of Veterans Affairs Dr. John TownsendFederated Cornea Societies/ASCRS . Dr. Michael BelinFood the manufacturer should specify the range over which the chart complies with this standard. ANSI Z80.21-2010 (R2015) 4 6 Marking The manufacturer shall
18、provide the following: a) Instructions for setup of the equipment. b) Maintenance required for continued compliance with the requirements of the standard. c) Safety requirements. d) Specification of replacements parts (e.g., lamps) if not supplied by the manufacturer of the original equipment. e) Sp
19、ecifications, including the ranges of visual acuity and luminance conditions within which the instrument complies with the standard. ANSI Z80.21-2010 (R2015) 5 Table 1 - Progression of optotypes, in terms of gap size of the equivalent Landolt ring Exact gap size (min of arc) Snellen fraction for tes
20、t distance Decimal acuity 6 m 5 m 4 m 5.08 m (20 ft) 0.501 6/3.0 5/2.5 4/2.0 20/10.0 2.000 0.631 6/3.8 5/3.2 4/2.5 20/12.5 1.600 0.794 6/4.8 5/4.0 4/3.2 20/16 1.250 1.000 6/6.0 5/5.0 4/4.0 20/20 1.000 1.259 6/7.5 5/6.3 4/5.0 20/25 0.800 1.585 6/9.5 5/8.0 4/6.3 20/32 0.630 1.995 6/12 5/10 4/8.0 20/40
21、 0.500 2.512 6/15 5/12.5 4/10 20/50 0.400 3.162 6/19 5/16 4/12.5 20/63 0.320 3.981 6/24 5/20 4/16 20/80 0.250 5.012 6/30 5/25 4/20 20/100 0.200 6.310 6/38 5/32 4/25 20/125 0.160 7.943 6/48 5/40 4/32 20/160 0.125 10.000 6/60 5/50 4/40 20/200 0.100 12.589 6/75 5/63 4/50 20/250 0.080 15.849 6/95 5/80 4
22、/63 20/320 0.063 19.953 6/120 5/120 4/80 20/400 0.050 ANSI Z80.21-2010 (R2015) 6 Annex A (normative) Method of correlating optotypes A.1 Scope This Annex specifies a method of correlation between a given set of optotypes and the standard optotype (Landolt ring) specified. A.2 General requirements fo
23、r optotypes A.2.1 Each size of a set of optotypes shall be specified in terms of the size of some critical dimension common to that set of optotypes. In the case of the standard Landolt ring, the critical detail is the gap size. In the case of a set of optotypes where there is no dimension common to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIZ80212010OPHTHALMICSINSTRUMENTSGENERALPURPOSECLINICALVISUALACUITYCHARTSVC 视力表 PDF

链接地址:http://www.mydoc123.com/p-439690.html