ANSI Z80.10-2014 Ophthalmics Ophthalmic Instruments C Tonometers (VC)《眼科仪器.眼压计》.pdf
《ANSI Z80.10-2014 Ophthalmics Ophthalmic Instruments C Tonometers (VC)《眼科仪器.眼压计》.pdf》由会员分享,可在线阅读,更多相关《ANSI Z80.10-2014 Ophthalmics Ophthalmic Instruments C Tonometers (VC)《眼科仪器.眼压计》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、American National Standardfor OphthalmicsOphthalmic Instruments TonometersANSI Z80.10-2014ANSIZ80.10-2014ANSIZ80.10-2014Revision ofANSI Z80.10-2009American National Standardfor Ophthalmics Ophthalmic Instruments TonometersSecretariatThe Vision CouncilApproved December 5, 2014American National Standa
2、rds Institute, Inc.Approval of an American National Standard requires review by ANSI that therequirements for due process, consensus, and other criteria for approval havebeen met by the standards developer.Consensus is established when, in the judgement of the ANSI Board ofStandards Review, substant
3、ial agreement has been reached by directly andmaterially affected interests. Substantial agreement means much more thana simple majority, but not necessarily unanimity. Consensus requires that allviews and objections be considered, and that a concerted effort be madetowards their resolution.The use
4、of American National Standards is completely voluntary; theirexistence does not in any respect preclude anyone, whether he has approvedthe standards or not, from manufacturing, marketing, purchasing, or usingproducts, processes, or procedures not conforming to the standards.The American National Sta
5、ndards Institute does not develop standards andwill in no circumstances give an interpretation of any American NationalStandard. Moreover, no person shall have the right or authority to issue aninterpretation of an American National Standard in the name of the AmericanNational Standards Institute. R
6、equests for interpretations should beaddressed to the secretariat or sponsor whose name appears on the titlepage of this standard.CAUTION NOTICE: This American National Standard may be revised orwithdrawn at any time. The procedures of the American National StandardsInstitute require that action be
7、taken periodically to reaffirm, revise, orwithdraw this standard. Purchasers of American National Standards mayreceive current information on all standards by calling or writing the AmericanNational Standards Institute.American National StandardPublished byThe Vision Council225 Reinekers Lane, Suite
8、 700Alexandria, VA 22314Copyright 2015 by The Vision CouncilAll rights reserved.No part of this publication may be reproduced in anyform, in an electronic retrieval system or otherwise,without prior written permission of the publisher.Printed in the United States of AmericaDeveloped byThe Accredited
9、 Committee Z80 for Ophthalmic Standards -The Vision CouncilZ80 Secretariat225 Reinekers Lane, Suite 700Alexandria, VA 22314iContentsPageForeword .i1 Scope . 12 Normative references . 13 Definitions. 24 Requirements . 25 Test methods 36 Accompanying documents . 47 Additional information. 48 Marking.
10、5Tables1 Requirements for paired testing of reference to test tonometers . 2AnnexesA The reference tonometer and method for determining reference IOP 6B Design compliance testing 13C Example of a test certificate . 17iiForeword (This foreword is not part of American National Standard ANSI Z80.10-201
11、4.)This American National Standard covers tonometers specifically intended for routineclinical use in the estimation of intraocular pressure for the detection, diagnosis, andmanagement of ocular abnormalities and excludes uses such as monitoring inducedhigh intraocular pressure for refractive surger
12、y.ANSI Z80.10-2014 was adapted by a group of experts within the ANSI OphthalmicInstruments Subcommittee under the chair of William L. Brown, O.D., Ph.D. It is aperformance standard.This standard defines the tolerable range of intraocular pressure (IOP) readings incomparison to measurements made by a
13、 reference applanation tonometer such asthe Goldmann Tonometer. Normative references have been updated. Allowance ismade in this standard for a Goldmann-equivalent measurement, taken with an instru-ment that meets requirements for a test tonometer when compared to the Goldmannreference tonometer. Su
14、ch an instrument may present intraocular pressure data informats other than Goldmann. This standard clarifies that a new tonometer thatmeets all of the specifications and requirements of annex A is qualified as a refer-ence tonometer, and, therefore, it does not require the clinical validation descr
15、ibed inannex B and clause 4.2.1. Added to annex B is clause B.9.3, which modifies require-ments for statistical analysis. Allowance for multiple measurements with the refer-ence tonometer during testing with the test tonometer is disallowed in this standardwith the deletion of clause B.9.2Annexes A
16、and B are normative and are considered part of the standard. Annex C isinformative and is not considered part of the standard.Suggestions for improvement of this standard will be welcome. They should be sentto the Vision Council, 225 Reinekers Lane, Suite 700, Alexandria, VA 22314.This standard was
17、processed and approved for submittal to ANSI by the AccreditedStandards Committee on Ophthalmic Optics, Z80. Committee approval of this stan-dard does not necessarily imply that all committee members voted for its approval. Atthe time of approval of this standard, the Z80 Committee consisted of the
18、followingmembers:Thomas White, M.D., ChairmanQuido Cappelli, Vice-ChairmanWilliam Benjamin, O.D., SecretaryJeff Endres, SecretariatiiiOrganization Represented Name of RepresentativeAdvance Medical Technologies Association .Michael PflegerAmerican Academy of OphthalmologyDr. Thomas WhiteAmerican Acad
19、emy of Optometry .Dr. David LoshinAmerican Ceramic SocietyLyle RubinAmerican Glaucoma Society.Dr. Steven GeddeAmerican Optometric Association .Dr. Karl CitekAmerican Society of Cataract and Refractive Ophthalmology Dr. Stephen KlyceContact Lens Institute .Stan RogaskiContact Lens Manufacturers Assoc
20、iationQuido CappelliDepartment of Veterans Affairs.Dr. John TownsendFederated Cornea Societies/ASCRS Dr. Michael BelinFood & Drug Administration Don CalogeroNational Association of Optometrists & Opticians.Nick MiletiOptical Laboratory Association .Michael VitaleOpticians Association of AmericaTom H
21、icksSunglass Association of AmericaFrederick GrethelThe Vision Council Jeffrey EndresU.S. TAG Leader to ISO TC 172/SC7.Jeffrey EndresThe members of the subcommittee on Ophthalmic Instruments who contributed tothis standard are:William L. Brown, O.D., Ph.D, ChairCharles E. CampbellBruce DrumDavid Luc
22、eRobert RosenbergivAMERICAN NATIONAL STANDARD ANSI Z80.10-2014American National Standard for Ophthalmics Ophthalmic Instruments Tonometers 1 1 Scope This standard, together with ISO 15004-1:2009, Fundamental requirements and test methods Part 1: General requirements applicable to all instruments Fir
23、st edition, specifies minimum requirements and the design compliance procedure for tonometers intended for routine clinical use in the estimation of intraocular pressure (IOP) for the detection, diagnosis, and management of ocular abnormalities. NOTES 1) The true intraocular pressure is seldom direc
24、tly measured since it would require invasion of the eye. Since the true IOP cannot be known, the instrument (annex A) and method (annex B) for determining a reference IOP are established. 2) Clinical tonometers may employ different parameters or correlates in the indirect assessment of measured IOP.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIZ80102014OPHTHALMICSOPHTHALMICINSTRUMENTSCTONOMETERSVC 眼科 仪器 眼压 PDF

链接地址:http://www.mydoc123.com/p-439684.html