ANSI UL 840-2005 UL Standard for Safety Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment (Third Edition Reprint with Revisions Through a.pdf
《ANSI UL 840-2005 UL Standard for Safety Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment (Third Edition Reprint with Revisions Through a.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 840-2005 UL Standard for Safety Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment (Third Edition Reprint with Revisions Through a.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 840 Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIB
2、UTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment, UL 840 Third Edition, Dated January 6, 2
3、005 Summary of Topics This revision to ANSI/UL 840 includes an updated title page to reect reaffirmation of ANSI approval. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a
4、vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated August 19, 2016. All rights reserv
5、ed. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or imp
6、lied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the
7、use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic ve
8、rsions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on th
9、e purchasers computer system. OCTOBER 5, 2016 UL 840 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 5, 2016 UL 840 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PE
10、RMISSION FROM UL JANUARY 6, 2005 (Title Page Reprinted: October 5, 2016) 1 UL 840 Standard for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment First Edition December, 1984 Second Edition May, 1993 Third Edition January 6, 2005 This ANSI/UL Standard for Sa
11、fety consists of the Third Edition including revisions through October 5, 2016. The most recent designation of ANSI/UL 840 as a Reaffirmed American National Standard (ANS) occurred on October 5, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Com
12、ments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor ele
13、ctronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 840-2012 (R2016)UL COPYRIGHTED MATERIAL NOT AUT
14、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 4, 2012 UL 840 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Glossary .5 3 Units of Measurement 6A 4 U
15、ndated References .6A 5 Components 6A 6 Insulation Coordination 7 CONSTRUCTION 7 Clearance A (Equivalency) .9 8 Clearance B (Controlled Overvoltage) 10 9 Creepage Distances .12 10 Measurement of Clearance and Creepage Distances .15 11 Use of Coatings to Achieve Insulation Coordination 23 PERFORMANCE
16、 12 Switching Test 23 13 Recurring Peak Voltage Determination .23 14 Dielectric Voltage-Withstand Tests .24 14.1 Testing in lieu of measuring clearances 24 14.2 Testing for controlled overvoltage .25 15 Printed Wiring Board Coating Performance Test 25 15.1 General .25 15.2 Dielectric voltage-withsta
17、nd test .27 15.3 Environmental cycling test 28 15.4 Humidity conditioning test 28 15.5 Thermal conditioning test .28 15.6 Coating adhesion .30 15.7 Insulation resistance between conductors 30 15.8 Impulse withstand voltage 31 15.9 Resistance to soldering heat 31 15.10 Flammability .31 15.11 Comparat
18、ive tracking index (CTI) .31 MAY 4, 2012 UL 840 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover an alternate approach to specifying through air and over surface spacings for electrical equip
19、ment through the use of the principles of insulation coordination. 1.2 The complete principles of insulation coordination involve the consideration of the combination of clearances, creepage distances, and the properties of solid insulation used to constitute the insulation system. The empirical dat
20、a gathered thus far has been used to develop the requirements for clearances and creepage distances as presented in this standard. The data needed to develop the evaluation procedure for solid insulation is still being gathered. When available, this evaluation procedure will be added to this standar
21、d and is not expected to affect the requirements for clearances and creepage distances. 1.3 These requirements may be used as an alternate to required spacing levels specied in end-product standards. The end product standard spacing requirements may be based on use and systems where overvoltages are
22、 not controlled, or if controlled, the level of control is unknown. 1.4 These alternate requirements are intended to be applied to a particular product category if the standard covering the product category specically references UL 840 or any of the requirements therein. 1.5 Users of these requireme
23、nts may need to specify the overvoltage levels and the methods of control which will be utilized, and establish the pollution degree to which the product insulation system will be expected to be subjected. 1.6 It is not intended that the test values in this standard be employed for production line t
24、esting. However, users of these requirements will need to establish a means to ensure that production controls applied to permit the spacing reduction remain in effect during the manufacture of the product. This could include sample testing or physical measurements or another equivalent means. 1.7 U
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL8402005ULSTANDARDFORSAFETYINSULATIONCOORDINATIONINCLUDINGCLEARANCESANDCREEPAGEDISTANCESFORELECTRICALEQUIPMENTTHIRDEDITIONREPRINTWITHREVISIONSTHROUGHAPDF

链接地址:http://www.mydoc123.com/p-439558.html