1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 83A Fluoropolymer Insulated Wire STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTH
2、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Fluoropolymer Insulated Wire, UL 83A First Edition, Dated February 1, 2016 Summary of Topics This revision of ANSI/UL 83A is to make an editorial correction to the title of the standard. Text that h
3、as been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying,
4、recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incident
5、al, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event sha
6、ll ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (
7、including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 10, 2016 UL 83A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM
8、 UL AUGUST 10, 2016 UL 83A tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2016 (Title Page Reprinted: August 10, 2016) 1 UL 83A Standard for Fluoropolymer Insulated Wire First Edition February 1, 2016 Thi
9、s ANSI/UL Standard for Safety consists of the First Edition including revisions through August 10, 2016. The most recent designation of ANSI/UL 83A as an American National Standard (ANSI) occurred on February 1, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages an
10、d Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a
11、 printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 83A-2016UL COPYRIGHTED MATERIAL
12、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS 1 Scope .4 2 General .4
13、 2.1 Units of measure .4 2.2 Reference publications 4 2.3 Summary of requirements .5 3 Denitions .5 4 Construction 6 4.1 Conductors 6 4.2 Insulation 9 4.3 Assemblies that include thermoplastic-insulated single conductors .11 4.4 Braids 11 5 Test requirements 11 5.1 General 11 5.2 Conductor resistanc
14、e 11 5.3 Short-term insulation resistance at elevated temperature in water .12 5.4 Long-term insulation resistance in water 12 5.5 Capacitance and relative permittivity of wet rated ( W type) wires 12 5.6 Flexibility at room temperature after aging 13 5.7 Cold bend and cold impact .13 5.8 Deformatio
15、n 13 5.9 Flame and smoke .14 5.10 Weather resistance (optional) 17 5.11 Oil resistance (optional) .17 5.12 Gasoline and oil resistance (optional) .17 5.13 Durability of ink printing .18 5.14 Color coating 18 5.15 Long-term aging of insulation 18 5.16 A-C spark test .18 5.17 Dielectric voltage-withst
16、and in water 19 5.18 Insulation resistance in water at 15C .19 5.19 Electrical continuity .19 6 Marking .19 6.1 Marking on product 19 6.2 Marking on package .22 6.3 Month and year of manufacture .22 TABLES .22 APPENDIX A (Informative) Summary of Requirements APPENDIX B (Informative) Metric Sizes APP
17、ENDIX C (Informative) Evaluation of Materials Having Characteristics Differing from Those in Table 12 FEBRUARY 1, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1 Scope 1.1 This Standard species t
18、he requirements for 600 V, single-conductor, uoropolymer-insulated wires and cables in accordance with NFPA 70, National Electrical Code (NEC). Note: See Appendix A for the complete list of wire types covered by this Standard. 1.2 Products for which this Standard provides requirements might have app
19、lications not described in the electrical code listed in 1.1. 2 General 2.1 Units of measure 2.1.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.2 Reference publications 2.2.1 Any undated reference to a code or standard app
20、earing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. UL Standards UL 1685 Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables UL 2556 Wire and Cable Test Methods ASTM (American Society
21、for Testing and Materials) Standards B3-13, Standard Specication for Soft or Annealed Copper Wire B8-11, Standard Specication for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft B33-10(2014), Standard Specication for Tinned Soft or Annealed Copper Wire for Electrical Purposes B
22、160-10(2014), Standard Specication for Nickel Rod and Bar B172-10(2015), Standard Specication for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors B173-10(2015), Standard Specication for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Member
23、s, for Electrical Conductors AUGUST 10, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL B174-10(2015), Standard Specication for Bunch-Stranded Copper Conductors for Electrical Conductors B355-11, S
24、tandard Specication for Nickel-Coated Soft or Annealed Copper Wire IEC (International Electrotechnical Commission) Standards 60228 (2004-11), Conductors of insulated cables NFPA (National Fire Protection Association) Publication NFPA 70, National Electrical Code (NEC) 2.3 Summary of requirements 2.3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL83A2016ULSTANDARDFORSAFETYFLOUROPOLYMERINSULATEDWIREFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-439557.html