ANSI UL 60079-2-2017 UL Standard for Safety Explosive Atmospheres - Part 2 Equipment Protection by Pressurized Enclosure p (Sixth Edition).pdf
《ANSI UL 60079-2-2017 UL Standard for Safety Explosive Atmospheres - Part 2 Equipment Protection by Pressurized Enclosure p (Sixth Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 60079-2-2017 UL Standard for Safety Explosive Atmospheres - Part 2 Equipment Protection by Pressurized Enclosure p (Sixth Edition).pdf(97页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60079-2 Explosive Atmospheres Part 2: Equipment Protection by Pressurized Enclosure p STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHO
2、UT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Explosive atmospheres Part 2: Equipment protection by pressurized enclosure p, UL 60079-2 Sixth Edition, Dated June 2, 2017 Summary of Topics UL
3、60079-2 is an adoption of IEC 60079-2, Explosive Atmospheres - Part 2: Equipment Protection by Pressurized Enclosure p (Edition 6, issued by IEC July, 2014). Please note that the national difference document incorporates all of the U.S. national differences for UL 60079-2. These new requirements are
4、 substantially in accordance with Proposal(s) on this subject dated December 16, 2016 and April 7, 2017. For further information regarding Summary of Requirements, please visit https:/ THIS SIXTH EDITION REPLACES THE FIFTH EDITION. AS OF JUNE 2, 2022, UL 60079-2 EDITION 5 WILL BE WITHDRAWN. All righ
5、ts reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either express
6、ed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising ou
7、t of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the elec
8、tronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Stand
9、ard on the purchasers computer system. JUNE 2, 2017 UL 60079-2 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 2, 2017 UL 60079-2 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION
10、 WITHOUT PERMISSION FROM UL JUNE 2, 2017 1 UL 60079-2 Standard for Explosive atmospheres Part 2: Equipment protection by pressurized enclosure p First Edition Not Printed Second Edition Not Printed Third Edition Not Printed Fourth Edition Not Printed Fifth Edition August, 2010 Sixth Edition June 2,
11、2017 This national standard is based on publication IEC 60079-2, Edition 6 issued July, 2014 (including corrigendum 1:2015). This ANSI/UL Standard for Safety consists of the Sixth Edition. The most recent designation of ANSI/UL 60079-2 as an American National Standard (ANSI) occurred on June 2, 2017
12、. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page or Preface. The National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to
13、 UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards an
14、d all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 60079-2-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 2,
15、2017 UL 60079-2 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 8 National Differences . 10 FOREWORD . 11 INTRODUCTION . 21 1 Scope .22 2 Normative references .22 3 Terms and denitions 23 4 Protect
16、ion levels .26 5 Constructional requirements for pressurized enclosures 28 5.1 Enclosure 28 5.2 Materials .29 5.3 Doors and covers .29 5.4 Mechanical strength .30 5.5 Group I and Group II Apertures, partitions, compartments and internal components . . .30 5.6 Apertures for Static Pressurization .31
17、5.7 Insulating materials for Group I equipment 31 5.8 Sealing .32 5.9 Spark and particle barriers 32 5.10 Cells and batteries .32 6 Temperature limits .32 6.1 General 32 6.2 For Level of Protection “pxb” or Level of Protection “pyb” .33 6.3 For Level of Protection “pzc” 33 7 Safety provisions and sa
18、fety devices (except for static pressurization) 33 7.1 Suitability of safety devices for hazardous area .33 7.2 Integrity of safety devices 34 7.3 Provider of safety devices 34 7.4 Pressurization System evaluated as associated equipment .35 7.5 Sequence diagram for Level of Protection “pxb” .36 7.6
19、Ratings for safety devices 36 7.7 Group I and Group II Purging automated for Level of Protection “pxb” .37 7.8 Group I or Group II Purging criteria 37 7.9 Group III Cleaning .38 7.10 Requirements when a minimum ow rate required .38 7.11 Safety devices to detect minimum overpressure 38 7.12 Value of
20、minimum overpressure 39 7.13 Pressurizing multiple enclosures .40 7.14 Safety devices on doors and covers 40 7.15 Equipment that may remain energized 40 7.16 Equipment permitted within Level of Protection “pyb” .41 8 Safety provisions and safety devices for static pressurization 41 8.1 Suitability o
21、f safety devices for hazardous area .41 8.2 Protective gas 41 8.3 Internal sources of release .41 8.4 Group I and Group II Filling procedure .41 8.5 Group III Filling Procedure 41 JUNE 2, 2017 UL 60079-2 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISS
22、ION FROM UL 8.6 Safety devices 42 8.7 Equipment that may remain energized .42 8.8 Overpressure .42 9 Supply of protective gas 42 9.1 Backup supply 42 9.2 Independent supplies 42 9.3 Type of gas .43 9.4 Temperature 43 10 Pressurized equipment with an internal source of release 43 11 Release condition
23、s 43 11.1 No release 43 11.2 Limited release of a gas or vapour .44 11.3 Limited release of a liquid .44 12 Design requirements for the containment system .44 12.1 General design requirements 44 12.2 Infallible containment system 45 12.3 Containment system with a limited release 45 13 Protective gas
24、 and pressurizing techniques when there is an internal source of release . . . . .46 13.1 General .46 13.2 Pressurization with leakage compensation .46 13.3 Pressurization with dilution 47 14 Ignition-capable equipment .48 15 Internal hot surfaces 48 16 Type verication and tests .49 16.1 Determining
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL6007922017ULSTANDARDFORSAFETYEXPLOSIVEATMOSPHERESPART2EQUIPMENTPROTECTIONBYPRESSURIZEDENCLOSUREPSIXTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-439322.html