ANSI UL 60079-17-2017 UL Standard for safety Explosive Atmospheres C Part 17 Electrical Installations Inspection and Maintenance (Fifth Edition).pdf
《ANSI UL 60079-17-2017 UL Standard for safety Explosive Atmospheres C Part 17 Electrical Installations Inspection and Maintenance (Fifth Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 60079-17-2017 UL Standard for safety Explosive Atmospheres C Part 17 Electrical Installations Inspection and Maintenance (Fifth Edition).pdf(63页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60079-17 Explosive Atmospheres Part 17: Electrical Installations Inspection and Maintenance STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION
2、 WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Explosive Atmospheres Part 17: Electrical Installations Inspection and Maintenance, UL 60079-17 Fifth Edition, Dated May 12, 2017 Summary o
3、f Topics Adoption of IEC 60079-17, Explosive Atmospheres Part 17: Electrical Installations Inspection and Maintenance (fth edition issued by IEC November 2013) as a new IEC-based UL standard, UL 60079-17 (IEC 60079-17:2013) with US Differences. The requirements are substantially in accordance with P
4、roposal(s) on this subject dated July 15, 2016 and February 17, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL
5、. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, includ
6、ing loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price
7、paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from an
8、y error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MAY 12, 2017 UL 60079-17 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 12, 2017 UL 60079-17 tr2 No Text on This Pag
9、eUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 12, 2017 1 UL 60079-17 Standard for Explosive Atmospheres Part 17: Electrical Installations Inspection and Maintenance Fifth Edition May 12, 2017 This ANSI/UL Standard for Safety consists
10、of the Fifth Edition. The most recent designation of ANSI/UL 60079-17 as an American National Standard (ANSI) occurred on May 12, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page or Preface. The National Difference Page and IEC Foreword are also exclu
11、ded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for S
12、afety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. A
13、NSI/UL 60079-17-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 12, 2017 UL 60079-17 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (U
14、L) 6 National Differences 8 FOREWORD 9 INTRODUCTION . 11 1 Scope .12 2 Normative references .12 3 Terms and denitions 14 4 General requirements 16 4.1 Documentation 16 4.2 Qualication of personnel .17 4.3 Inspections .17 4.4 Periodic inspections .20 4.5 Continuous supervision by skilled personnel 21
15、 4.6 Maintenance requirements 24 4.7 Environmental conditions .26 4.8 Isolation of equipment .27 4.9 Earthing and equipotential bonding 30 4.10 Specic conditions of use .30 4.11 Movable equipment and its connections .30 4.12 Inspection schedules (Tables 1 to 3) 30 5 Additional inspection schedule re
16、quirements 33 5.1 Type of protection “d” Flameproof enclosure (see Table 1 and IEC 60079-1 UL 60079-1) .33 5.2 Type of protection “e” Increased safety (see Table 1 and IEC 60079-7 UL 60079-7) .34 5.3 Type of protection “i” Intrinsic safety (see Table 2 and IEC UL 60079-11) 35 5.4 Type of protection
17、“p” and “pD” Pressurized enclosure (see Table 3, IEC 60079-2 UL 60079-2 and IEC 61241-4) .38 5.5 Type of protection “n” (see Table 1 or 2 and IEC 60079-15) 39 5.6 Type of protection “t” and “tD” Protection by enclosure (see Table 1 and IEC 60079-31 UL 60079-31 and IEC 61241-1) 39 5.7 Types of protec
18、tion “m” and “mD” (encapsulation), “o”, (oil-immersion) “op” (optical radiation) and “q” (powder-lling) 39 6 Inspection tables .39 Annex A (informative) Typical inspection procedure for periodic inspections Annex B (normative informative) Knowledge, skills and competencies of responsible persons, te
19、chnical persons with executive function and operatives B.1 Scope 49 B.2 Knowledge and skills .49 B.2.1 Responsible persons and technical persons with executive function .49 B.2.2 Operative/technician (inspection and maintenance) 50 B.3 Competencies .50 MAY 12, 2017 UL 60079-17 3UL COPYRIGHTED MATERI
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL60079172017ULSTANDARDFORSAFETYEXPLOSIVEATMOSPHERESCPART17ELECTRICALINSTALLATIONSINSPECTIONANDMAINTENANCEFIFTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-439319.html