ANSI UL 2577-2013 UL Standard for Safety Suspended Ceiling Grid Low Voltage Systems and Equipment (First Edition Reprint with revisions through and including February 16 2017)《吊式电网.pdf
《ANSI UL 2577-2013 UL Standard for Safety Suspended Ceiling Grid Low Voltage Systems and Equipment (First Edition Reprint with revisions through and including February 16 2017)《吊式电网.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 2577-2013 UL Standard for Safety Suspended Ceiling Grid Low Voltage Systems and Equipment (First Edition Reprint with revisions through and including February 16 2017)《吊式电网.pdf(51页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2577 Suspended Ceiling Power Grid Systems and Equipment STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRI
2、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Suspended Ceiling Power Grid Systems and Equipment, UL 2577 First Edition, Dated February 7, 2013 Summary of Topics The following changes in requirements to the Joint UL/ULC S
3、tandard for Suspended Ceiling Power Grid Systems and Equipment, UL 2577/ULC-S2577, are being issued for the United States and Canada: Add new denition for Low Voltage/Extra-Low Voltage and revise voltage references throughout the standard to correlate with the Canadian Electrical Code, Part 1, and t
4、he National Electrical Code, NFPA 70 Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The revised requirements are substantially in accordance with Proposal(s) on this subject dated August 5, 2016. All rights reser
5、ved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard “as is” without warranty of any kind, either expressed or
6、implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of t
7、he use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic
8、 versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on
9、 the purchasers computer system. FEBRUARY 16, 2017 UL 2577 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 16, 2017 UL 2577 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION W
10、ITHOUT PERMISSION FROM UL Prepared by: ULC Standards CAN/ULC-S2577 First Edition Underwriters Laboratories Inc. ANSI/UL 2577 First Edition Suspended Ceiling Power Grid Systems and Equipment February 7, 2013 (Title Page Reprinted: February 16, 2017) ANSI/UL 2577-2017 Approved byUL COPYRIGHTED MATERIA
11、L NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This Standard is issued jointly by Underwriters Laboratories Inc. (UL) and ULC Standards. Amendments to this Standard will be made only after processing according to the Standards writing p
12、rocedures by UL and ULC Standards. UL and ULC Standards are separate and independent entities and each is solely responsible for its operations and business activities. The UL trade names and trademarks depicted in this document are the sole property of Underwriters Laboratories Inc. The ULC Standar
13、ds trade names and trademarks depicted in this document are the sole property of ULC Standards. ISSN 0317-526X Copyright 2017 ULC Standards All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, whatsoever without the prior per
14、mission of the publisher. In Canada, written comments are to be sent to ULC Standards, 400 171 Nepean Street, Ottawa, Ontario KP2 0B4. Proposals should be submitted on a Standards Revision Request Form available from ULC Standards. Copyright 2017 Underwriters Laboratories Inc. ULs Standards for Safe
15、ty are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the F
16、irst Edition including revisions through February 16, 2017. The most recent designation of ANSI/UL 2577 as an American National Standard (ANSI) occurred on February 16, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface.
17、 Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. To purchase UL Standards, visit Comm 2000 at http:/m- or call toll-fr
18、ee 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface . 5 INTRODUCTION 1 Scope .6 2 Components 7 3 Units of Measurement .8 4 Undated References 8 5 Glossary .8 MECHANICAL CONSTRUCTION 6 General 8B 7 Assembly and
19、Mounting 8B 8 Metal Components .8B 9 Polymeric Enclosure and Insulation Materials .10 9.1 General 10 9.2 Flammability 10 9.3 Relative Thermal Index (RTI) .11 9.4 Electrical properties 11 10 System Flammability 11 11 Adhesives .11 12 Strain Relief 12 ELECTRICAL CONSTRUCTION 13 General .12 14 Current-
20、Carrying Parts 13 15 Securement of Components 13 16 Splices and Connections 14 17 Electrical Spacings 15 18 Class 2 Power Supplies and Transformers .15 19 Luminaires .16 20 Switches and Controls .16 21 Control Circuits .17 22 Class 2 Supply and Load Connectors .18 22.1 General .18 22.2 Power feed co
21、nnector 18 22.3 Load connectors .19 23 Field Wiring 19 23.1 Field wiring terminals .19 23.2 Separation for CEC/NEC Class 2 circuits 20 PERFORMANCE 24 Connector Tests 21 24.1 General .21 24.2 Movable connector cycle conditioning and temperature test .21 24.3 Field-installed conductors conditioning an
22、d temperature test .22 24.4 Fixed connector cycling test .22 FEBRUARY 16, 2017 CAN/ULC-S2577 ANSI/UL 2577 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 25 System Temperature Test .22 25.1 General .22 25.2 Test setup grid rail system .24 2
23、5.3 Test setup power supplies and low voltage/extra-low voltage equipment 24 26 Mechanical Assembly Load Test 24 27 Moment Test .25 28 System Flammability Test Grid Rails 25 29 System Flammability Test Discrete Components Located In Air-Handling Spaces .26 30 Mold Stress-Relief Distortion Test .27 3
24、1 Connector Drop Test 27 32 Field Cutting Test .28 33 Conductor Secureness Test 28 34 Strain Relief Test .29 35 Push-Back Relief Test for Conductors or Cable 29 36 Dielectric Voltage Withstand Test .30 MARKINGS 37 Details .31 37.1 General .31 37.2 Connectors 32 37.3 Air-handling use 33 37.4 Correlat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL25772013ULSTANDARDFORSAFETYSUSPENDEDCEILINGGRIDLOWVOLTAGESYSTEMSANDEQUIPMENTFIRSTEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGFEBRUARY162017

链接地址:http://www.mydoc123.com/p-439136.html