ANSI UL 25-2016 UL Standard for Safety Meters for Flammable and Combustible Liquids and LP-Gas (Ninth Edition Reprint with revisions through and including October 7 2016).pdf
《ANSI UL 25-2016 UL Standard for Safety Meters for Flammable and Combustible Liquids and LP-Gas (Ninth Edition Reprint with revisions through and including October 7 2016).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 25-2016 UL Standard for Safety Meters for Flammable and Combustible Liquids and LP-Gas (Ninth Edition Reprint with revisions through and including October 7 2016).pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 25 Meters for Flammable and Combustible Liquids and LP-Gas STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COP
2、YRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Meters for Flammable and Combustible Liquids and LP-Gas, UL 25 Ninth Edition, Dated April 19, 2016 SUMMARY OF TOPICS This revision of ANSI/UL 25 is being issued to add torq
3、ue requirements for larger size valve. The revisions are substantially in accordance with Proposal(s) on this subject dated August 26, 2016. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No
4、part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, i
5、ncluding but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of
6、or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions
7、of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purch
8、asers computer system. OCTOBER 7, 2016 UL 25 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 7, 2016 UL 25 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
9、FROM UL APRIL 19, 2016 (Title Page Reprinted: October 7, 2016) 1 UL 25 Standard for Meters for Flammable and Combustible Liquids and LP-Gas The rst edition was titled Liquid-Phase Meters for LP-Gas. The second through fourth editions were titled Meters for Flammable Liquids and LP-Gas. First Edition
10、 March, 1956 Second Edition April, 1959 Third Edition June, 1968 Fourth Edition December, 1973 Fifth Edition June, 1979 Sixth Edition September, 1990 Seventh Edition May, 1996 Eighth Edition January, 2003 Ninth Edition April 19, 2016 This ANSI/UL Standard for Safety consists of the Ninth Edition inc
11、luding revisions through October 7, 2016. The most recent designation of ANSI/UL 25 as an American National Standard (ANSI) occurred on October 7, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of
12、the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in
13、any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 25-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT
14、PERMISSION FROM UL APRIL 19, 2016 METERS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS AND LP-GAS - UL 25 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 5 2.1 Components .5 2.2 Units
15、of measurement .5 2.3 Undated references .5 CONSTRUCTION 3 General 5 4 Assembly 6 5 Materials .6 6 Bodies and Covers 8 7 Register-Shaft Seals 9 8 Springs 9 9 Piping and Fittings 9 PERFORMANCE 10 General 11 11 Deformation Test .11 12 Leakage Test 12 13 Endurance Test 13 14 Hydrostatic Strength Test 1
16、3 15 Temperature Reduction Test .14 16 Moist Ammonia-Air Stress Cracking Test 14 MANUFACTURING AND PRODUCTION TESTS 17 General 14 MARKING 18 General 15 19 Permanence of Marking .16 APPENDIX A Standards for Components .A1 APRIL 19, 2016 METERS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS AND LP-GAS - UL 25
17、3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover positive displacement liquid meters for: a) Flammable and combustible liquids of the type and size commonly used in the assembly of motor fuel
18、 dispensing devices and b) Liqueed petroleum gas (LP-Gas) of the type and size commonly used in the assembly of motor fuel dispensing devices and tank trucks. 1.2 Flammable and Combustible Liquids, as used herein, means gasoline, gasoline/alcohol blends up to 15% Ethanol or 15% Methanol, diesel fuel
19、, fuel oil, lubricating oil, kerosene, and the vapors of these fuels. Other petroleum products are not prohibited from being used in the meter when the materials comply with the requirements in Materials, Section 5, and when the meter is evaluated using the additional liquids. Petroleum products sha
20、ll be handled at pressures not exceeding 50 pounds per square inch gauge (psig) (345 kPa) and at temperatures within the range of minus 29C (20F) 52C (125F). 1.3 Flammable and combustible liquid meters covered by this standard are for use in accordance with the National Fire Protection Associations
21、Flammable and Combustible Liquids Code, NFPA 30, and the Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 30A. 1.4 LP-Gas meters covered by this standard are for use in nonrefrigerated systems in accordance with the National Fire Protection Associations Liqueed Petroleum Gas Code,
22、NFPA 58. 1.5 These requirements do not cover: a) Meters for use with liqueed petroleum gas in the gaseous phase; b) Velocity meters, head meters, or area meters; c) Meters for use in centralized fuel oil distribution systems; and d) Meter components incorporating electrical circuits except those mee
23、ting intrinsically safe or explosion standards. 1.6 Determinations of the suitability of registers, counters, or computers used or provided with these meters, or the accuracy of measurement resulting from or required in actual application are not within the scope of these requirements. APRIL 19, 201
24、6 METERS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS AND LP-GAS - UL 25 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply wi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL252016ULSTANDARDFORSAFETYMETERSFORFLAMMABLEANDCOMBUSTIBLELIQUIDSANDLPGASNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGOCTOBER72016PDF

链接地址:http://www.mydoc123.com/p-439123.html