ANSI UL 248-1-2011 UL Standard for Safety Low-Voltage Fuses C Part 1 General Requirements (Third Edition Reprint with Revisions Through and Including June 16 2017)《低压保险丝安全标准.第1部分 一.pdf
《ANSI UL 248-1-2011 UL Standard for Safety Low-Voltage Fuses C Part 1 General Requirements (Third Edition Reprint with Revisions Through and Including June 16 2017)《低压保险丝安全标准.第1部分 一.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 248-1-2011 UL Standard for Safety Low-Voltage Fuses C Part 1 General Requirements (Third Edition Reprint with Revisions Through and Including June 16 2017)《低压保险丝安全标准.第1部分 一.pdf(53页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 248-1 Low-Voltage Fuses Part 1: General Requirements STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHT
2、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Low-Voltage Fuses - Part 1: General Requirements UL 248-1 Third Edition, Dated May 13, 2011 Summary of Topics Revision pages have been issued for the Standard for Safety for Low-Voltage Fuses Part 1: Gener
3、al Requirements, UL 248-1, to incorporate the following proposals: Editorial correction in Table 5. Recovery voltage clarication. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The new/revised requirements are su
4、bstantially in accordance with Proposal(s) on this subject dated March 24, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permi
5、ssion of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar dama
6、ges, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed
7、 the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) result
8、ing from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JUNE 16, 2017 UL 248-1 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 16, 2017 UL 248-1 tr2 No Text on T
9、his PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Association of Standardization and Certication NMX-J-009/248/1-ANCE Second Edition Canadian Standards Association CSA C22.2 No. 248.1-11 Third Edition Underwriters Laboratories Inc. UL
10、248-1 Third Edition Low-Voltage Fuses Part 1: General Requirements May 13, 2011 (Title Page Reprinted: June 16, 2017) ANSI/UL 248-1-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly
11、 by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operating as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL at anytime. Revisions to t
12、his standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same re
13、visions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages. Copyright 2017 ANCE Rights reserved in favor of ANCE. ISBN 978-1-55491-642-9 2017 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the p
14、rior permission of the publisher. This Standard is subject to review ve years from the date of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org and include Pr
15、oposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at shop.csa.ca or call toll-free 1-8
16、00-463-6727 or 416-747-4044. Copyright 2017 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall
17、 remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Third Edition including revisions through June 16, 2017. The most recent designation of ANSI/UL 248-1 as an American National Standard (ANSI) occurred on June 16, 2017. ANSI approval for a standard does n
18、ot include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development Syste
19、m (CSDS) at https:/. To purchase UL Standards, visit ULs Standards Sales Site at http:/ HowToOrder.aspx or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface . 5 1 General 7 1.1 Scope .7 1.2 Object
20、 .7 2 Denitions .7 2.1 Fuse .7 2.2 General terms 8 2.3 Characteristic quantities 10 3 Service conditions .12 4 Classication 12 5 Characteristics 12 5.1 Summary of Characteristics .12 5.2 Voltage rating .13 5.3 Current rating .13 5.4 Frequency rating 13 5.5 Interrupting rating 13 5.6 Peak let-through
21、 current and clearing I 2 t characteristics 13 6 Marking 13 6.1 Marking of fuses .13 6.2 Marking symbols 14 7 Construction 14 7.1 Dimensions .14 7.2 Current-carrying parts 14 7.3 Connections 14 7.4 Adhesives 14 7.5 Contact alignment .15 7.6 Body .15 7.7 Corrosion protection .15 8 Tests 15 8.1 Genera
22、l .15 8.2 Verication of temperature rise and current-carrying capacity .17 8.3 Verication of overload operation 20 8.4 Verication of operation at rated voltage 21 8.5 Verication of peak let-through current and clearing I 2 t characteristics .26 ANNEX A (normative) Circuit calibration for interruptin
23、g rating tests A1 Galvanometers .27 A2 Circuit calibration .28 A3 DC circuit calibration example 30 MAY 13, 2011 NMX-J-009/248/1-ANCE CSA C22.2 NO. 248.1-11 UL 248-1 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ANNEX B (normative) Instru
24、mentation for interrupting rating tests B1 Power factor determination 32 B2 Available current 34 B3 Peak let-through current .34 B4 Recovery voltage .36 B5 Comparison of instrumentation .39 B6 Determination of I 2 t .39 B7 Oscillogram example 39 MAY 13, 2011 NMX-J-009/248/1-ANCE CSA C22.2 NO. 248.1-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL24812011ULSTANDARDFORSAFETYLOWVOLTAGEFUSESCPART1GENERALREQUIREMENTSTHIRDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJUNE162017

链接地址:http://www.mydoc123.com/p-439105.html