《ANSI UL 2255-2011 UL Standard for Safety Receptacle Closures (Second Edition Reprint with Revisions Through and Including November 1 2016)《插座封盖的安全标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 2255-2011 UL Standard for Safety Receptacle Closures (Second Edition Reprint with Revisions Through and Including November 1 2016)《插座封盖的安全标准》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2255 Receptacle Closures STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED F
2、OR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Receptacle Closures, UL 2255 Second Edition, Dated February 14, 2011 SUMMARY OF TOPICS: Revision pages have been issued for the Standard for Receptacle Closures, UL 2255, to reect the November 1, 2016 reaff
3、irmation of the ANSI approval. No changes in requirements have been made. The revisions are substantially in accordance with Proposal(s) on this subject dated September 16, 2016. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line i
4、n the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of an
5、y kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any ot
6、her damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the cl
7、aim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is stori
8、ng an electronic Standard on the purchasers computer system. NOVEMBER 1, 2016 UL 2255 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 1, 2016 UL 2255 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR
9、ODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 14, 2011 (Title Page Reprinted: November 1, 2016) 1 UL 2255 Standard for Receptacle Closures First Edition February, 1999 Second Edition February 14, 2011 This ANSI/UL Standard for Safety consists of the Second Edition including revisions
10、through November 1, 2016. The most recent designation of ANSI/UL 2255 as an American National Standard (ANSI) occurred on November 1, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard
11、may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All
12、of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 2255-2012 (R2016)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PER
13、MISSION FROM UL FEBRUARY 14, 2011 RECEPTACLE CLOSURES - UL 2255 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Glossary .5 3 Components .5 4 Units of Measurement .6 5 References 6 CON
14、STRUCTION 6 General 6 7 Insulating Materials .6 8 Dimensions 7 PERFORMANCE 9 Mold Stress Relief Test .10 10 Blade Strength Test .11 10.1 General .11 10.2 Vertical blade orientation .11 10.3 Horizontal blade orientation, at of blade 11 10.4 Horizontal blade orientation, edge of blade .11 MARKINGS 11
15、Details .13 APPENDIX A Standards for ComponentsA1 FEBRUARY 14, 2011 RECEPTACLE CLOSURES - UL 2255 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL This page intentionally left blank. FEBRUARY 14, 2011 RECEPTACLE CLOSURES - UL 2255 4UL COPYRI
16、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover products which are molded of insulating material and are intended to cover the outlet slots of receptacles having 1-15R and 5-15R congurations in accord
17、ance with Wiring Devices-Dimensional Specications, ANSI/NEMA WD6. 1.2 These requirements do not cover insulating devices provided to cover the unused outlets of a multi-outlet cord connector employed on a general-use cord set. The requirements for these devices are contained in the Standard for Cord
18、 Sets and Power-Supply Cords, UL 817. 1.3 These requirements do not cover receptacle closures provided as part of a ush device cover plate. These devices are covered by the requirements in the Standard for Metallic Outlet Boxes, UL 514A, or in the Standard for Nonmetallic Outlet Boxes, Flush-Mounted
19、 Boxes, and Covers, UL 514C. 2 Glossary 2.1 For the purposes of this Standard, the following denition applies. 2.2 RECEPTACLE CLOSURE A product molded of insulating material intended to be used to cover the outlet slots of a receptacle to: a) Reduce drafts through a receptacle on an outside wall of
20、a dwelling, or b) Restrict a childs access to energized contacts. 3 Components 3.1 Except as indicated in 3.2, a component of a product covered by this Standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the pro
21、ducts covered by this Standard. 3.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 3.3 A com
22、ponent shall be used in accordance with its rating established for the intended conditions of use. 3.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures
23、 not exceeding specied limits, and shall be used only under those specic conditions. FEBRUARY 14, 2011 RECEPTACLE CLOSURES - UL 2255 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4 Units of Measurement 4.1 When a value for measurement is
24、followed by a value in other units in parentheses, the second value may be only approximate. The rst stated value is the requirement. 5 References 5.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL22552011ULSTANDARDFORSAFETYRECEPTACLECLOSURESSECONDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGNOVEMBER12016

链接地址:http://www.mydoc123.com/p-439080.html