ANSI UL 2218-2010 UL Standard for Safety Impact Resistance of Prepared Roof Covering Materials (Second Edition Reprint with Revisions Through and Including January 12 2018).pdf
《ANSI UL 2218-2010 UL Standard for Safety Impact Resistance of Prepared Roof Covering Materials (Second Edition Reprint with Revisions Through and Including January 12 2018).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 2218-2010 UL Standard for Safety Impact Resistance of Prepared Roof Covering Materials (Second Edition Reprint with Revisions Through and Including January 12 2018).pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2218 Impact Resistance of Prepared Roof Covering MaterialsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NO
2、T AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Impact Resistance of Prepared Roof Covering Materials, UL 2218 Second Edition, Dated January 25, 2010 SUMMARY OF TOPICS Revision pages have been issued for the Standard for Safety for Impact R
3、esistance of Prepared Roof Covering Materials, UL 2218, to incorporate the following proposals: Clarication on preparation of samples fo UL 2218 Impact Tests. First time ANSI approval of UL 2218. The revised requirements are substantially in accordance with Proposal(s) on this subject dated February
4、 3, 2012 and April 9, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without
5、warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of d
6、ata, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the
7、form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purc
8、haser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected it
9、em. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. MAY 1, 2012 UL 2218 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMIS
10、SION FROM UL MAY 1, 2012 UL 2218 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 25, 2010 (Title Page Reprinted: May 1, 2012) 1 UL 2218 Standard for Impact Resistance of Prepared Roof Covering Materials First
11、Edition May, 1996 Second Edition January 25, 2010 This ANSI/UL Standard for Safety consists of the Second Edition. The most recent designation of ANSI/UL 2218 as an American National Standard (ANSI) occurred on May 1, 2012. ANSI approval for a standard does not include the Cover Page, Transmittal Pa
12、ges, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safet
13、y are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC. ANSI/
14、UL 2218-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 25, 2010 IMPACT RESISTANCE OF PREPARED ROOF COVERING MATERIALS - UL 2218 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTIO
15、N WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 4 PERFORMANCE 3 General 4 4 Preparation of Samples 5 4.1 General .5 4.2 Preparation of test decks 5 4.3 Application .5 4.4 Conditioning .5 5 Test Apparatus .6 6 Test Procedure .9 7 Acceptance Criteria .9 REPORT 8 General .10 9 C
16、lasses of Prepared Roof Coverings for Impact Resistance .10 APPENDIX A A1 Relationship Between Steel Balls and Impacts from Hailstones A1 A2 Precision and Bias .A1 JANUARY 25, 2010 IMPACT RESISTANCE OF PREPARED ROOF COVERING MATERIALS - UL 2218 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REP
17、RODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This test method provides impact resistance data for the evaluation of prepared roof covering materials. For purposes of this Standard prepared roof covering materials are considered to be small units, sheets or panels des
18、igned for installation with multiple layers of such materials installed in overlapping rows normally on inclines exceeding 25 percent. 1.2 The test evaluates the effect of impact from the steel ball at locations on the assembly selected to be most vulnerable, such as (but not limited to) edges, corn
19、ers, unsupported sections and joints. 1.3 This test method does not evaluate the effect of weathering, temperature, aging or similar effects on the impact resistance of prepared roof covering materials. These and other factors, including time, roof slope, roof system conguration and application inue
20、nce the performance of roong materials in the eld. It is not the objective of this test to address all of these factors. 1.4 The impact energies used in this Standard were derived from impact energies of actual hailstones (see Appendix A). However, largely due to the effects discussed in 1.3, there
21、is no currently established direct correlation between the performance of roof covering materials when impacted by hailstones versus steel balls. Consequently, this test method does not provide a direct basis to compare expected performance under all hail conditions, but does provide a basis for com
22、parison of the response of roof coverings when subjected to the impact energies described herein. 2 General 2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. PERFORMANCE 3 General 3.1 Representative samples of roof covering m
23、aterial, assembled to test decks as described in Preparation of Samples, Section 4, are to be subjected to the impact tests described in Test Apparatus, Section 5, and Test Procedure, Section 6. JANUARY 25, 2010 IMPACT RESISTANCE OF PREPARED ROOF COVERING MATERIALS - UL 2218 4UL COPYRIGHTED MATERIAL
24、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4 Preparation of Samples 4.1 General 4.1.1 Representative samples of a roof covering material are to be applied, as described in 4.3, to test decks constructed as described in 4.2. The assemblies are to be conditione
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL22182010ULSTANDARDFORSAFETYIMPACTRESISTANCEOFPREPAREDROOFCOVERINGMATERIALSSECONDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY122018PDF

链接地址:http://www.mydoc123.com/p-439069.html