ANSI UL 2079-2015 UL Standard for Safety Tests for Fire Resistance of Building Joint Systems (Fifth Edition).pdf
《ANSI UL 2079-2015 UL Standard for Safety Tests for Fire Resistance of Building Joint Systems (Fifth Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 2079-2015 UL Standard for Safety Tests for Fire Resistance of Building Joint Systems (Fifth Edition).pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2079 Tests for Fire Resistance of Building Joint SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT
2、AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Tests for Fire Resistance of Building Joint Systems, UL 2079 Fifth Edition, Dated August 26, 2015 Summary of Topics This new edition of ANSI/UL 2079 was issued to incorporate the following chang
3、e: Revision to requirements for TC Modication. The revised requirements are substantially in accordance with Proposal(s) on this subject dated April 3, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, ele
4、ctronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL b
5、e liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibili
6、ty of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liabi
7、lity, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 26, 2015 UL 2079 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR D
8、ISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 26, 2015 UL 2079 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL August 26, 2015 1 UL 2079 Standard for Tests for Fire Resistance of Building Joint Systems First Edition N
9、ovember, 1994 Second Edition January, 1997 Third Edition July, 1998 Fourth Edition October, 2004 Fifth Edition August 26, 2015 This ANSI/UL Standard for Safety consists of the Fifth Edition. The most recent designation of ANSI/UL 2079 as an American National Standard (ANSI) occurred on August 26, 20
10、15. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Developm
11、ent System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL.
12、 COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 2079-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 26, 2015 TESTS FOR FIRE RESISTANCE OF BUILDING JOINT SYSTEMS - UL 2079 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT A
13、UTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .6 3 Undated References 7 4 Glossary .7 TEST ASSEMBLY 5 General 8 6 Floor-to-Floor Joint Systems 8 7 Wall-to-Wall Joint Systems .9 8 Floor-to-Wall Joint Systems 9 9 H
14、ead-of-Wall Joint Systems 9 10 Conditioning 10 FIRE ENDURANCE TEST 11 Test Furnace .11 12 Time-Temperature Curve 12 13 Furnace Temperatures 13 14 Furnace Pressure .14 15 Temperatures of the Unexposed Surface 15 16 Integrity 16 17 Conduct of Fire Endurance Test 16 HOSE STREAM TEST 18 Test Assembly .1
15、7 19 Conduct of Hose Stream Test 17 OPTIONAL AIR LEAKAGE TEST 20 Test Assembly .18 21 Apparatus 18 22 Conduct of Air Leakage Tests 19 23 Air Leakage Rate Calculation 20 OPTIONAL WATER LEAKAGE TEST 24 Test Sample .20 25 Test Chamber 20 26 Test Setup .22 27 Recorded Test Data .22 ENVIRONMENTAL EXPOSUR
16、E TESTS FOR INTUMESCENT MATERIAL 28 Environmental Exposure Tests for Intumescent Material 22 28.1 General .22 28.2 Required environmental exposures .23 AUGUST 26, 2015 TESTS FOR FIRE RESISTANCE OF BUILDING JOINT SYSTEMS - UL 2079 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DI
17、STRIBUTION WITHOUT PERMISSION FROM UL 28.3 Supplemental environmental exposures .23 28.4 Expansion pressure test 24 28.5 Expansion factor test .25 FIRE ENDURANCE RATING 29 Conditions of Acceptance 25 30 Correction .26 31 L rating 26 32 W rating .27 33 Report of Results .27 APPENDIX A A1 Standard Tim
18、e-Temperature Curve for Control of Fire Tests .A1 APPENDIX B B1 Requirements for Thermocouple Pads B1 Appendix C C1 Background information for the W-Rating .C1 AUGUST 26, 2015 TESTS FOR FIRE RESISTANCE OF BUILDING JOINT SYSTEMS - UL 2079 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTI
19、ON OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These tests are applicable to joint systems of various materials and construction that are intended for use in linear openings between adjacent re resistive structures. 1.2 The re endurance ratings for joint systems are intended
20、to register performance during the period of re exposure and are not intended to be interpreted as having determined the acceptability of the joint systems for use before or after re exposure. The intent of these methods is to develop data to assist others in determining the suitability of the joint
21、 systems where re resistance is required. 1.3 These requirements are intended to evaluate the length of time that the types of joint systems specied in 1.1 will contain a re during a predetermined test exposure. The test evaluates the joint systems resistance to heat and, in some instances, to a hos
22、e stream, while carrying an applied load if the assembly is load bearing. The method of testing also includes optional air leakage tests to determine the rate of air leakage through joint systems resulting from a specied air pressure difference applied across the surface of the joint systems. 1.4 Un
23、der these requirements a joint system is subjected to a standard re exposure controlled to achieve specied temperatures throughout a specied time period. This exposure by itself is not intended to be representative of all re conditions; conditions vary with changes in the amount, nature and distribu
24、tion of re loading, ventilation, compartment size and conguration, and heat sink characteristics of the compartment. 1.5 All joint systems are cycled through their intended range of movement prior to re exposure to demonstrate the joint systems range of movement and the impact of the joint system du
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL20792015ULSTANDARDFORSAFETYTESTSFORFIRERESISTANCEOFBUILDINGJOINTSYSTEMSFIFTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-439037.html