1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1777 Chimney LinersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O
2、R DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Chimney Liners, UL 1777 Fifth Edition, Dated October 2, 2015 Summary of Topics This Fifth Edition of the Standard for Chimney Liners, ANSI/UL 1777, has been issued as an Editorial update only. No changes to the requirements have be
3、en made. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kin
4、d, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other d
5、amages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim.
6、Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an
7、 electronic Standard on the purchasers computer system. OCTOBER 2, 2015 UL 1777 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 2, 2015 UL 1777 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTIO
8、N OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 2, 2015 1 UL 1777 Standard for Chimney Liners First Edition March, 1988 Second Edition April, 1995 Third Edition February, 2004 Fourth Edition November, 2007 Fifth Edition October 2, 2015 This ANSI/UL Standard for Safety consists of the Fifth Edit
9、ion. The most recent designation of ANSI/UL 1777 as a Reaffirmed American National Standard (ANS) occurred on April 15, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitt
10、ed to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standard
11、s and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1777-2009 (R2014)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL
12、 OCTOBER 2, 2015 CHIMNEY LINERS - UL 1777 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .5 3 Glossary .5 4 Components 6 5 Undated References 7 CONSTRUCTION 6 Mat
13、erials .7 7 Assembly 9 8 Chimney Caps .11 9 Chimney Top Covers .11 10 Joints .11 11 Wall Penetration Assemblies .12 12 Radiation Shields .13 13 Tee Sections and Support Assemblies for Metallic Chimney Liners .14 PERFORMANCE 14 General 14 15 Test Installation .15 16 Temperature Measurement 23 17 Temp
14、erature Test for Solid-Fuel-Fired Appliances 1000F (538C) Flue Gases .29 18 Temperature Test for Solid-Fuel-Fired Appliances 1400F (760C) Flue Gases .30 19 Temperature Test for Solid-Fuel-Fired Appliances 2100F (1149C) Flue Gases 30 20 Temperature Test for Oil-Fired Appliances 570F (299C) Flue Gases
15、 31 21 Temperature Test for Oil-Fired Appliances 1700F (927C) Flue Gases .31 22 Temperature Test for Category I Gas-Fired Appliances 470F (243C) Flue Gases .32 23 Loading Test for Metallic Chimney Liners 32 24 Vertical Support Test for Metallic Chimney Liners .33 25 Strength Test for Metallic Chimne
16、y Liners .35 26 Strength Test for Nonmetallic Chimney Liners 37 27 Sweep Test 38 28 Abrasion Test 38 29 Flexibility Test for Flexible Metal Liners 39 30 Torsion Test for Flexible Metal Liners .40 31 Corrosion Resistance Test .40 32 Comparative Corrosion Exposure Test for Aluminum Liners 41 33 Compar
17、ative Corrosion Exposure Test for Stainless Steel Liners .42 34 Resistance to Action of Acids Test for Nonmetallic Flue-Gas Conduit .43 35 Freezing and Thawing Test for Water-Absorptive Nonmetallic Materials .43 36 Rain Test 44 37 Draft Loss and Wind Effects Test .47 38 Puncture Test for Flexible Al
18、uminum Metal Liners 49 MARKINGS 39 General 51 OCTOBER 2, 2015 CHIMNEY LINERS - UL 1777 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INSTRUCTIONS 40 General 52 41 Installation Instructions 53 42 Maintenance Instructions 54 OCTOBER 2, 2015
19、 CHIMNEY LINERS - UL 1777 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover metallic and nonmetallic chimney liners intended for eld-installation into new or existing masonry chimneys that are
20、 used for the natural draft venting of Category I gas-red, Type L vented oil-red, and solid-fuel-red residential-type appliances in which the maximum continuous ue-gas outlet temperatures do not exceed 1000F (538C). 1.2 Chimney liners are intended to be installed in existing masonry chimneys with or
21、 without a liner of re-clay tile, or to be used as a substitute for masonry re-clay tile ue liners in new chimneys. 1.3 Chimney liners are intended to be installed in accordance with the Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, NFPA 211; National Fuel Gas Code, NF
22、PA 54 and codes such as the International Building Code, International Gas Code, International Mechanical Code, International Residential Code, and the Uniform Mechanical Code. 1.4 Chimney liners as covered by these requirements are not intended for use with Category II, III, or IV gas burning appli
23、ances as dened by the National Fuel Gas Code, NFPA 54, or other appliances that result in condensation of corrosive acids on the liner of the chimney, or that create positive pressures in the chimney system. 1.5 Chimney liners with cementitious or refractory ue gas conveying conduits shall be evalua
24、ted and marked in accordance with the solid-fuel-red-appliance sections of these requirements. 2 Units of Measurement 2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3 Glossary 3.1 For the purpose of this standard, the foll
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL17772015ULSTANDARDFORSAFETYCHIMNEYLINERSFIFTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-438984.html