ANSI UL 127-2011 UL Standard for Safety Factory-Built Fireplaces (Ninth Edition Reprint with revisions through and including July 27 2016)《工厂生产壁炉的安全标准》.pdf
《ANSI UL 127-2011 UL Standard for Safety Factory-Built Fireplaces (Ninth Edition Reprint with revisions through and including July 27 2016)《工厂生产壁炉的安全标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 127-2011 UL Standard for Safety Factory-Built Fireplaces (Ninth Edition Reprint with revisions through and including July 27 2016)《工厂生产壁炉的安全标准》.pdf(151页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 127 Factory-Built Fireplaces STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZ
2、ED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Factory-Built Fireplaces, UL 127 Ninth Edition, Dated April 21, 2011 Summary of Topics This revision to ANSI/UL 127 includes updates to obsolete code references. The revisions also address other miscell
3、aneous universal upkeep of UL for Standards Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No
4、part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, i
5、ncluding but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of
6、or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions
7、of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purch
8、asers computer system. JULY 27, 2016 UL 127 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 27, 2016 UL 127 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FR
9、OM UL APRIL 21, 2011 (Title Page Reprinted: July 27, 2016) 1 UL 127 Standard for Factory-Built Fireplaces First Edition October, 1958 Second Edition January, 1960 Third Edition July, 1970 Fourth Edition September, 1971 Fifth Edition November, 1981 Sixth Edition September, 1988 Seventh Edition May, 1
10、996 Eighth Edition July, 2008 Ninth Edition April 21, 2011 This ANSI/UL Standard for Safety consists of the Ninth Edition including revisions through July 27, 2016. The most recent designation of ANSI/UL 127 as an American National Standard (ANSI) occurred on May 26, 2015. ANSI approval for a standa
11、rd does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Developmen
12、t System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. C
13、OPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 127-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 28, 2015 FACTORY-BUILT FIREPLACES - UL 127 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
14、 OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 Glossary .8 3 Components .8 3.1 General 8 3.2 Attachment plugs, receptacles, connectors, and terminals 10 3.3 Boxes and raceways .11 3.4 Capacitors and lters 11 3.5 Controls 12 3.6 Cords, cables, and internal wiring .14 3
15、.7 Overcurrent protection .15 3.8 Polymeric materials and enclosures .15 3.9 Power supplies 16 3.10 Printed wiring boards .16 3.11 Switches 16 3.12 Transformers 17 4 Units of Measurement 17 4A Undated References 18 5 Terms .18 CONSTRUCTION 6 Materials 18 6.1 General .18 6.2 Air duct system .21 7 Ass
16、embly .22 7.1 General .22 7.2 Joints 23 7.3 Firestop spacers 23 7.4 Support assembly .23 7.5 Radiation shield .24 7.6 Flue damper 24 7.7 Chimney caps .25 7.8 Roof assemblies 25 7.9 Firescreens .26 7.10 Chimney elbows .26 7.11 Gas pipe provision .27 7.12 Air duct system 27 7.13 Handles .27 7.14 Integ
17、ral grates .27 7.15 Openings in chimney walls 27 PERFORMANCE 8 General .28 9 Test Installations 29 10 Temperature Measurement 44 11 Preconditioning Tests 61 11.1 General .61 MAY 28, 2015 FACTORY-BUILT FIREPLACES - UL 127 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTIO
18、N WITHOUT PERMISSION FROM UL 11.2 Thermal shock test .61 11.3 Temperature test 1700F ue gases 64 11.4 Temperature test 2100F ue gases 65 12 Radiant Fire Test .67 13 Brand Fire Test .71 14 Flash Fire Test 75 15 Optional Unvented Decorative Log Temperature Test 75 16 Support Test 76 17 Fire Chamber St
19、rength Test 76 18 Chimney Strength Test .81 18.1 General .81 18.2 Impact test 82 18.3 Longitudinal force test 84 18.4 Load test for chimney elbows 84 18.5 Chimney joint load test 85 18.6 Chimney joint torsion test .86 19 Wind Load Test 86 20 Rain Test .87 21 Crushing Test of Nonmetallic Flue-Gas Con
20、duit or Insulation .91 22 Resistance to Action of Acids Test of Nonmetallic Flue-Gas Conduit .92 23 Freezing and Thawing Test of Water-Absorptive Nonmetallic Materials 92 24 Cemented Joint Test of Flue-Gas Conduit 93 25 Sulfuric Acid Extraction Test for Porcelain-Coated Steel Used for Flue-Gas Condu
21、it . . .93 26 Glazing Test 94 26.1 General .94 26.2 Impact test 94 26.3 Water shock test .95 OUTDOOR FIREPLACES 27 General 96 28 Construction 96 29 Performance 96 29.1 General .96 29.2 Hot and cold conditioning test 96 29.3 Freezing and thawing tests for refractory materials .97 29.4 Wind test 98 30
22、 Marking 98 31 Operating Instructions 98 FIREPLACES FOR USE IN MANUFACTURED HOMES 32 General 99 32.1 Installation 99 32.2 Chimney 99 32.3 Spark arrester 100 32.4 Combustion air inlet .100 32.5 Test structure .100 32.6 Test method 101 32.7 Drop test .102 MAY 28, 2015 FACTORY-BUILT FIREPLACES - UL 127
23、 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL BLOWER ASSEMBLY GENERAL 33 General 102 CONSTRUCTION 34 Enclosure .103 34.1 General .103 34.2 Mechanical protection 106 34.3 Electrical protection 107 34.4 Doors and covers 110 35 Mounting of
24、Electrical Components 111 36 Field-Installed Blower Assemblies 112 37 Field Supply Connections .113 38 Grounding .115 39 Internal Wiring .116 39.1 General .116 39.2 Methods 117 40 Separation of Circuits 119 41 Bonding for Grounding 120 42 Capacitors .122 43 Insulating Material 122 44 Motors and Moto
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL1272011ULSTANDARDFORSAFETYFACTORYBUILTFIREPLACESNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJULY272016

链接地址:http://www.mydoc123.com/p-438847.html