ANSI UL 125-2014 UL Standard for Safety Flow Control Valves for Anhydrous Ammonia and LP-Gas (Ninth Edition Reprint with revisions through and including January 12 2018).pdf
《ANSI UL 125-2014 UL Standard for Safety Flow Control Valves for Anhydrous Ammonia and LP-Gas (Ninth Edition Reprint with revisions through and including January 12 2018).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 125-2014 UL Standard for Safety Flow Control Valves for Anhydrous Ammonia and LP-Gas (Ninth Edition Reprint with revisions through and including January 12 2018).pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 125 Flow Control Valves for Anhydrous Ammonia and LP-GasUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT
2、AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Flow Control Valves for Anhydrous Ammonia and LP-Gas, UL 125 Ninth Edition, Dated March 19, 2014 Summary of Topics This revision of ANSI/UL 125 is being issued to include the following changes:
3、Update Glossary denition in 6.6 to reect the current NFPA denition; Clarify the materials used for a lever on a hose nozzle valve, addition of Exception No. 3 to 8.3; Revision to the Deformation Test to delete machine oil in 23.2; Deletion of the second External Leakage Test in 23.3; Revision to the
4、 Moist Ammonia Air Stress Cracking Test, 34.2 to replace Teon with PTFE tape. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed
5、by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated October 10, 2014. All rights reserved. No part of this publication may be repro
6、duced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the impl
7、ied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard
8、, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to
9、defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requiremen
10、ts in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effecti
11、ve date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. FEBRUARY 18, 2015 UL 125 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 18, 2015 UL 125 tr2 No Text on This PageUL COPYRIGHTED MATERIA
12、L NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 19, 2014 (Title Page Reprinted: February 18, 2015) 1 UL 125 Standard for Flow Control Valves for Anhydrous Ammonia and LP-Gas The rst through seventh editions were titled Standard for Valves for Anhydrous Ammo
13、nia and LP-Gas (Other Than Safety Relief). First Edition October, 1956 Second Edition July, 1973 Third Edition February, 1974 Fourth Edition February, 1980 Fifth Edition March, 1993 Sixth Edition February, 1997 Seventh Edition April, 2007 Eighth Edition June, 2009 Ninth Edition March 19, 2014 This A
14、NSI/UL Standard for Safety consists of the Ninth Edition including revisions through February 18, 2015. The most recent designation of ANSI/UL 125 as an American National Standard (ANSI) occurred on February 18, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, T
15、itle Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are
16、copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 125
17、-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 19, 2014 FLOW CONTROL VALVES FOR ANHYDROUS AMMONIA AND LP-GAS - UL 125 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT P
18、ERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Service Pressure Rating .6 3 General 7 3.1 Components .7 4 Units of Measurement .7 5 Undated References 8 6 Glossary .8 CONSTRUCTION 7 General 9 8 Materials 10 9 Bodies 12 10 Springs 12 11 Shutoff Valves All .12 12 Shutoff Valves Automatic 13 13 E
19、xcess Flow Valves .13 14 Back Pressure Check Valves .14 15 Filler Valves 14 16 Vapor Return Valves 15 17 Actuated Liquid Withdrawal Excess-Flow Valves 15 18 Multiple Function Valves .17 19 Internal Valves .17 20 Emergency Shutoff Valves .18 21 Lever Operated Transfer Valves and LP-Gas Hose Nozzle Va
20、lves 18 PERFORMANCE 22 General 19 23 Deformation Test .20 24 External Leakage Test 21 25 Positive Seal Test 21 26 Seat Leakage Test 21 27 Endurance Test 24 28 Hydrostatic Strength Test 25 29 Operation Test .25 29.1 General .25 29.2 Air tests .26 29.3 Water tests 26 30 Weak Section Strength Test .27
21、31 Accelerated Aging Test 27 32 Fluid Compatibility Test 27 33 Low Temperature Test 28 34 Moist Ammonia Air Stress Cracking Test 28 35 Thermal Link Operation Test .29 36 Fire Test .29 37 Drop Test 30 38 Impact Test 30 MARCH 19, 2014 FLOW CONTROL VALVES FOR ANHYDROUS AMMONIA AND LP-GAS - UL 125 3UL C
22、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 39 Valve Stem Torque Test .31 40 Start-To-Discharge Pressure Test .31 MANUFACTURING AND PRODUCTION TESTS 41 General 32 MARKING 42 General 33 MARCH 19, 2014 FLOW CONTROL VALVES FOR ANHYDROUS AMMONIA
23、 AND LP-GAS - UL 125 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover the following types of anhydrous ammonia and liqueed petroleum gas (LP-Gas) valves that are used to control the ow of liq
24、uid and/or vapor into and out of containers, or in piping systems between containers, or between containers and utilization equipment, and are for use at temperatures within the range of minus 40F (minus 40C) to 130F (55C): a) Shutoff Valves (primary or secondary, and manual or automatic), b) Excess
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL1252014ULSTANDARDFORSAFETYFLOWCONTROLVALVESFORANHYDROUSAMMONIAANDLPGASNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY122018PDF

链接地址:http://www.mydoc123.com/p-438843.html