ANSI UL 1242-2006 UL Standard for Safety Electrical Intermediate Metal Conduit C Steel (Fourth Edition Reprint with Revisions Through and Including June 25 2018)《电子过渡金属导管.钢》.pdf
《ANSI UL 1242-2006 UL Standard for Safety Electrical Intermediate Metal Conduit C Steel (Fourth Edition Reprint with Revisions Through and Including June 25 2018)《电子过渡金属导管.钢》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1242-2006 UL Standard for Safety Electrical Intermediate Metal Conduit C Steel (Fourth Edition Reprint with Revisions Through and Including June 25 2018)《电子过渡金属导管.钢》.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1242 Electrical Intermediate Metal Conduit Steel STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED M
2、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Electrical Intermediate Metal Conduit Steel, UL 1242 Fourth Edition, Dated February 16, 2006 Summary of Topics This revision to ANSI/UL 1242 includes a clarication to Table 9.1. Text
3、 that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The revised requirements are substantially in accordance with Proposal(s) on this subject dated May 11, 2018. All rights reserved. No part of this publication may be rep
4、roduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the im
5、plied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standa
6、rd, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree t
7、o defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JUNE 25, 201
8、8 UL 1242 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 25, 2018 UL 1242 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 16, 2006 (Title Pa
9、ge Reprinted: June 25, 2018) 1 UL 1242 Standard for Electrical Intermediate Metal Conduit Steel First Edition October, 1983 Second Edition July, 1996 Third Edition July, 2000 Fourth Edition February 16, 2006 This ANSI/UL Standard for Safety consists of the Fourth Edition, including revisions through
10、 June 25, 2018. The most recent designation of ANSI/UL 1242 as an American National Standard (ANSI) occurred on June 25, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. The Department of Defense (DoD) has adopted UL 1242 on May 21, 1984. The pub
11、lication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Developmen
12、t System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL.
13、COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 1242-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 5, 2014 ELECTRICAL INTERMEDIATE METAL CONDUIT STEEL - UL 1242 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED F
14、OR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .5 3 References .5 4 Glossary .5 CONSTRUCTION 5 General 6 6 Protective Coatings .6 6.1 General .6 6.2 Surface treatments 6A 6.3 Supplementary coatings .7 6.4 Alternate corrosion
15、-resistant coatings .7 7 Threading and Chamfering 7 7.1 General .7 7.2 Protection of threads 8 7.3 Dimensions of threads 8 7.4 Taper of threads 9 8 Thread Gauging 9 9 Straight Conduit .10 10 Nipples 11 11 Elbows 11 12 Couplings 12 PERFORMANCE 13 Identication of Compounds 14 14 Bending .14 14.1 Ambie
16、nt temperature .14 14.2 Low temperature 15 15 Protective Coatings .15 15.1 Zinc coating .15 15.2 Alternate corrosion-resistant coatings 17 15.3 Organic coatings 20 16 Tensile Strength and Adhesion .21 17 Cold Impact Test .22 18 Flammability Test .22 18.1 General .22 18.2 Preparations 22 18.3 Conduct
17、 of the test 25 19 Beam-Strength .25 20 Threaded-Conduit Pullout 26 MARKINGS 21 Details .27 MARCH 5, 2014 ELECTRICAL INTERMEDIATE METAL CONDUIT STEEL - UL 1242 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL EXAMINATION OF FINISHED PRODUCT
18、BY MANUFACTURER 22 General 28 FEBRUARY 16, 2006 ELECTRICAL INTERMEDIATE METAL CONDUIT STEEL - UL 1242 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover steel electrical intermediate metal cond
19、uit (IMC), nipples, elbows, and couplings. This conduit is provided in trade sizes 1/2 4 (16 103), for use as a metal raceway for the installation of wires and cables in accordance with the National Electrical Code (NEC), NFPA 70. The values in parentheses are metric designators of conduit. 1.2 Stee
20、l intermediate metal conduit is provided both internally and externally with an acceptable level of corrosion resistance in normally corrosive environments. Reference 6.1 for details regarding protective coatings. 2 Units of Measurement 2.1 Values stated without parentheses are the requirement. Valu
21、es in parentheses are explanatory or approximate information. 3 References 3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 4 Glossary 4.1 For purposes of this standard the
22、 following denitions apply. 4.2 COATING(S), ALTERNATE CORROSION-RESISTANT A coating(s) (other than one consisting solely of zinc) that, upon evaluation, has demonstrated the ability to provide the level of corrosion resistance required on the exterior of conduit. Coatings may include zinc. See 15.2.
23、 4.3 COATING(S), ORGANIC A coating(s) (other than one consisting solely of zinc) that, upon evaluation, has demonstrated the ability to provide the level of corrosion resistance necessary where the coating is not subject to physical damage, such as on the interior of conduit. The coatings may includ
24、e zinc. See 15.3. 4.4 COATING(S), ZINC A coating consisting solely of zinc, that, upon evaluation, has demonstrated the ability to provide the level of corrosion resistance required for the exterior or interior of the conduit as applicable. See 15.1. JUNE 25, 2018 ELECTRICAL INTERMEDIATE METAL CONDU
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL12422006ULSTANDARDFORSAFETYELECTRICALINTERMEDIATEMETALCONDUITCSTEELFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJUNE252018

链接地址:http://www.mydoc123.com/p-438840.html