ANSI UL 1077-2015 UL Standard for Safety Supplementary Protectors for Use in Electrical Equipment (Seventh Edition Reprint with revisions through and including August 18 2016)《电气设备.pdf
《ANSI UL 1077-2015 UL Standard for Safety Supplementary Protectors for Use in Electrical Equipment (Seventh Edition Reprint with revisions through and including August 18 2016)《电气设备.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1077-2015 UL Standard for Safety Supplementary Protectors for Use in Electrical Equipment (Seventh Edition Reprint with revisions through and including August 18 2016)《电气设备.pdf(61页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1077 Supplementary Protectors for Use in Electrical Equipment STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL
2、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Supplementary Protectors for Use in Electrical Equipment, UL 1077 Seventh Edition, Dated June 25, 2015 Summary of Topics This revision of ANSI/UL 1077 incorporates the f
3、ollowing: 1. Clarication for Measuring Spacings as Described in Table 16.1 The revised requirements are substantially in accordance with Proposal(s) on this subject dated March 11, 2016 and June 17, 2016. Text that has been changed in any manner or impacted by ULs electronic publishing system is mar
4、ked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as
5、 is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost saving
6、s, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regard
7、less of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduce
8、d while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 18, 2016 UL 1077 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 18, 2016 UL 1077 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUT
9、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 25, 2015 (Title Page Reprinted: August 18, 2016) 1 UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment First Edition September, 1975 Second Edition July, 1981 Third Edition January, 1987 Fourth
10、 Edition April, 1994 Fifth Edition June, 1999 Sixth Edition July, 2005 Seventh Edition June 25, 2015 This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through August 18, 2016. The most recent designation of ANSI/UL 1077 as an American National Standard (ANSI) occur
11、red on August 18, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborativ
12、e Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclu
13、sive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 1077-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 25, 2015 SUPPLEMENTARY PROTECTORS FOR USE IN ELECTRICAL EQUIPMENT - UL 1077 2 No Text on This PageUL COP
14、YRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Glossary .5 3 Components .7 4 Units of Measurement .7 5 Undated References 7 CONSTRUCTION 6 General 7 7 Corrosion Protection 8 8 Insulating Materials .8 9 Current-C
15、arrying Parts 9 10 Wiring Terminals .10 11 Pressure Wire Connectors 12 12 Wiring Leads 12 13 Wire-Binding Screw Terminals 13 14 Mounting .13 15 Operating Mechanism 13 16 Spacings .14 17 Clearance and Creepage Distances .15 PERFORMANCE 18 General 17 OVERCURRENT PROTECTORS 19 Calibration .20 20 Temper
16、ature 21 21 Overload Test .24 22 Endurance 29 23 Dielectric Strength and Voltage-Withstand Tests 30 23.1 Dielectric strength test 30 23.2 Voltage-withstand test 30 23.3 Details 30 24 Recalibration .31 25 Short Circuit 31 26 Strain Relief 38 ACCESSORIES 27 All Accessories .39 27.1 General .39 27.2 In
17、stallation .39 27.3 Mounting 40 27.4 Field wiring 40 27.5 Strain relief 40 27.6 Spacings 41 JUNE 25, 2015 SUPPLEMENTARY PROTECTORS FOR USE IN ELECTRICAL EQUIPMENT - UL 1077 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 28 Auxiliary Switch
18、es 41 28.1 General .41 28.2 Temperature .42 28.3 Overload 42 28.4 Endurance 43 28.5 Dielectric voltage-withstand 44 29 Overvoltage-Trip Release Devices 44 30 Overvoltage-Trip Appliance Protectors .45 30.1 General .45 30.2 Temperature .45 30.3 Overvoltage .45 30.4 Operation .45 30.5 Overload 45 30.6
19、Endurance 45 30.7 Dielectric voltage-withstand 46 31 Undervoltage-Trip Protectors .46 31.1 General .46 31.2 Temperature .46 31.3 Overvoltage .46 31.4 Operation .46 31.5 Overload 46 31.6 Endurance 47 31.7 Dielectric voltage-withstand 47 32 Shunt-Trip Protectors 47 32.1 General .47 32.2 Temperature .4
20、7 32.3 Overvoltage .47 32.4 Undervoltage 47 32.5 Overload 47 32.6 Endurance 48 32.7 Dielectric voltage-withstand 48 RATINGS 33 Details .48 MARKING 34 Specics .48 APPENDIX A Standards for ComponentsA1 APPENDIX B Examples of Valid U and C Code Combinations JUNE 25, 2015 SUPPLEMENTARY PROTECTORS FOR US
21、E IN ELECTRICAL EQUIPMENT - UL 1077 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to supplementary protectors intended for use as overcurrent, or over- or under-voltage protection within a
22、n appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. Compliance with the following is acceptable for use as a component of an end product. 1.2 The acceptability of a protector in any particular application depends upon its abi
23、lity to be used continuously under the conditions that prevail in actual service. Accordingly, for a particular application a protector may be affected by the requirements for the equipment it is used in, and it may be necessary to additionally evaluate features or performance characteristics that a
24、re not specied in this Standard. 1.3 This Standard also covers accessory devices that may be installed in or on the protector to perform a secondary function. Examples of accessories are alarm and auxiliary switches. 1.4 Devices which ensure a manual restart due to the complete loss of voltage are c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL10772015ULSTANDARDFORSAFETYSUPPLEMENTARYPROTECTORSFORUSEINELECTRICALEQUIPMENTSEVENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGAUGUST182016

链接地址:http://www.mydoc123.com/p-438801.html