《ANSI TIA EIA 455-180-A-1999 FOTP-180 Measurement of the Optical Transfer Coefficients of a Passive Branching Device (Coupler)《FOTP-180,无源分支器件的光传播系数测量》.pdf》由会员分享,可在线阅读,更多相关《ANSI TIA EIA 455-180-A-1999 FOTP-180 Measurement of the Optical Transfer Coefficients of a Passive Branching Device (Coupler)《FOTP-180,无源分支器件的光传播系数测量》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/TIA/EIA-455-18O-A-I999 Approved: November 29,1999 TIAIEIA STANDARD FOTP480 Measurement of the Optical Transfer Coefficients of a Passive Branching Device (Coupler) TIAEIA -455- 180-A (Revision of EIATIA-455-180) DECEMBER 1999 TELECOMMUNICATIONS INDUSTRY ASSOCIATION Representing the telecommunic
2、ations industry in association with the Electronic Industries Alliance Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE TiAEIA Engineering Standards and Publications are d
3、esigned to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existenc
4、e of such Standards and Publications shall not in any respect preclude any member or nonmember of TIA/EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other t
5、han TiAEIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by TiAEIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TiAEIA does not assume any liability to any patent owner,
6、 nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate
7、 safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 4536, formulated under the cognizance of the TIA FO-6.3 Subcommittee on Fiber Optic Interconnecting Devices.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 19
8、99 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 PRICE: Please refer to current Catalog of PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-7179) International (303-397-7956) EIA ELECTRONIC INDUSTRIES ALLIANCE STANDARDS and ENGINEERING All
9、rights reserved Printed in U.S.A. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for
10、 ResaleNo reproduction or networking permitted without license from IHS-,-,-TIA/EIA-455- 180-A FOTP- 180 MEASUREMENT OF THE OPTICAL TRANSFER COEFFICIENTS OF A PASSIVE BRANCHING DEVICE (COUPLER) CONTENTS Section Method 2 is applicable to Class A, B and C devices, but is less precise than Method 1 bec
11、ause it introduces the unknown loss of a TJ. 10 Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TIA/EIA-455-180-A DEVICE UNDER TEST LAUNCH DETECTOR r r r O O r O O For multimode
12、 devices, four measurement conditions are allowed as specified in Table 1. The letter Y refers to restricted and the letter “o“ refers to overfilled. The designations under the heading “Device Under Test“ spec conditions for the Pl(h) measurement and those for the Po(h) measurement. REFERENCE LAUNCH
13、 DETECTOR r r r O O O O O Table 2. Measurement Conditions for Multimode Branching Devices 5.1.1.1 Method 1 (Cutback) - Class A Branching Device 1) The selected input and output ports of the BD are connected to the measurement setup as shown in Figure 7. Refer to 3.2.2.1. The lengths of the input por
14、t (Ll) and output port (L2) shall be specified in the Detail Specification, but shall be sufficiently short that the signal attenuation over the stated lengths is insignificant by comparison to the insertion loss of the BD. To avoid measurement errors, the fiber ends at the TJ shall not be displaced
15、 during the measurement process of Pl(h) . The power Pl(h) at the detector(D) is then recorded for each wavelength of interest. The power level shall be repeatable when the fiber is withdrawn and recoupled to the detector. 2) After ensuring that the measurement of Pl(h) is sufficiently stable, the f
16、iber between the TJ and the BD is cut as shown in Figure 8. The length of the cutback section (Ll) shall be 1 to 2 meters (3 to 6 ft) or as specified in the relevant Detail Specification. 11 Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo repr
17、oduction or networking permitted without license from IHS-,-,-TIA/EIA-455- 180-A Note: (Figure 8) If a cladding mode stripper was initially placed on the input port it shall also be included and remain undisturbed in the cutback section (Ll). Also, if a high order mode filter was initially placed on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSITIAEIA455180A1999FOTP180MEASUREMENTOFTHEOPTICALTRANSFERCOEFFICIENTSOFAPASSIVEBRANCHINGDEVICECOUPLERFOTP180

链接地址:http://www.mydoc123.com/p-438245.html