1、TAPPI/ANSI T 428 om-13 TENTATIVE STANDARD 1932 OFFICIAL STANDARD 1940 SUGGESTED METHOD 1967 PROVISIONAL METHOD 1977 REVISED 1985 OFFICIAL METHOD 1991 REVISED 1999 REVISED 2004 REAFFIRMED 2008 REAFFIRMED 2013 2013 TAPPI The information and data contained in this document were prepared by a technical
2、committee of the Association. The committee and the Association assume no liability or responsibility in connection with the use of such information or data, including but not limited to any liability under patent, copyright, or trade secret laws. The user is responsible for determining that this do
3、cument is the most recent edition published. Approved by the Standard Specific Interest Group for this Test Method TAPPI CAUTION: This Test Method may include safety precautions which are believed to be appropriate at the time of publication of the method. The intent of these is to alert the user of
4、 the method to safety issues related to such use. The user is responsible for determining that the safety precautions are complete and are appropriate to their use of the method, and for ensuring that suitable safety practices have not changed since publication of the method. This method may require
5、 the use, disposal, or both, of chemicals which may present serious health hazards to humans. Procedures for the handling of such substances are set forth on Material Safety Data Sheets which must be developed by all manufacturers and importers of potentially hazardous chemicals and maintained by al
6、l distributors of potentially hazardous chemicals. Prior to the use of this method, the user must determine whether any of the chemicals to be used or disposed of are potentially hazardous and, if so, must follow strictly the procedures specified by both the manufacturer, as well as local, state, an
7、d federal authorities for safe use and disposal of these chemicals. Hot water extractable acidity or alkalinity of paper 1. Scope 1.1 This method, based on the work of Kohler and Hall (1), measures the titratable acidity or alkalinity (end point at pH 7.0) of an aqueous extract of paper (filtered an
8、d extracted by boiling water for 1 h). It specifies one extraction and so does not measure the total acidity or alkalinity of paper, for which exhaustive extraction is required. 1.2 It may be applied to writing, printing, and sized industrial paper but is not intended for testing electrical insulati
9、ng papers. NOTE 1: This method measures the pH of the bulk extract as prepared in the method, and as such, measures the combined acidity and alkalinity of the base paper and any added fillers or coating materials. 2. Summary This method consists of a boiling water extraction of the specimen followed
10、 by an alkalinity-acidity titration of the extract solution. 3. Significance The pH determination measures the extent to which the paper alters the hydrogen-hydroxyl ion equilibrium of pure water, and the acidity-alkalinity determination measures the quantity of extracted ionic material that contrib
11、utes to that equilibrium change. These tests are useful for routine acceptance testing, research work, or the evaluation and classification of different papers. T 428 om-13 Hot water extractable acidity or alkalinity of paper / 2 4. Definitions 4.1 Paper acidity, the extent to which water-soluble ma
12、terials in the paper alter the hydrogen-hydroxyl ion equilibrium of pure water causing an excess of hydrogen ions as measured by titrating with a standardized solution of alkali under specified conditions. 4.2 Paper alkalinity, the extent to which water-soluble materials in the paper alter the hydro
13、gen-hydroxyl ion equilibrium of pure water causing an excess of hydroxyl ions as measured by titrating with a standardized solution of acid under specified conditions. 5. Apparatus 5.1 pH meter, a pH Meter of Type II, III, or IV as described in Table 2, Laboratory pH Meter, ASTM Specification D 1293
14、, Standard Test Method for pH of Water is satisfactory. The pH meter shall be calibrated and used in accordance with ASTM Specification E 70, Standard Test Method for Determining pH of Aqueous Solutions with the Glass Electrode. 5.2 Erlenmeyer flask, 500-mL with a 24/40 standard taper joint. 5.3 Con
15、denser, West or Allihn type, with 300-mm jacket; or an air condenser about 12 mm OD and 750 mm long; each with a 24/40 standard taper drip-tip joint. 5.4 Bchner funnel, 60-mL, glass, with medium fritted disk. 5.5 Burets, two 50-mL. 5.6 Beaker, 400-mL. 5.7 Graduated cylinders, 100- and 250-mL. 5.8 Ho
16、t plate, preferably with temperature adjustment. 5.9 Magnetic stirrer. 6. Reagents 6.1 Sodium hydroxide, 0.01N NaOH, accurately standardized (see TAPPI T 610 “Preparation of Indicators and Standard Solutions”). 6.2 Hydrochloric or sulfuric acid, 0.01N HCl or H2SO4, accurately standardized (see TAPPI
17、 T 610). 6.3 Distilled or deionized water, the water used in this test method shall conform to Reagent Water, Type II or Type I as described in ASTM Specification D 1193, Standard Specification for Reagent Water. 6.4 Carbon dioxide-free gas, nitrogen, or purified air. Air, if used, should be oil-fre
18、e. Pass the air through a gas washing bottle containing at least 200 mL of 3N H2SO4and then through a tower or U-tube containing ascarite or soda lime, 120-150 mm long, before connecting to the gas dispensing tube. 7. Sampling Obtain a sample of the paper in accordance with TAPPI T 400 “Sampling and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIT428OM2004HOTWATEREXTRACTABLEACIDITYORALKALINITYOFPAPERPDF

链接地址:http://www.mydoc123.com/p-438087.html