1、ROUND INDUSTRIAL DUCT CONSTRUCTION STANDARDSSHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC. www.smacna.orgANSI/SMACNA 0052013ROUND INDUSTRIAL DUCT CONSTRUCTION STANDARDSTHIRD EDITION 2013SHEET METAL AND AIR CONDITIONING CONTRACTORSNATIONAL ASSOCIATION, INC.4201 Lafayette Cent
2、er DriveChantilly, VA 20151-1209www.smacna.orgROUND INDUSTRIAL DUCT CONSTRUCTION STANDARDSCOPYRIGHT1977, 2013All Rights Reserved bySHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC.4201 Lafayette Center DriveChantilly, VA 201511219Printed in the U.S.A.FIRST EDITION 1977SECOND ED
3、ITION 1999THIRD EDITION 2013ISBN 978-1-61721-106-5 PrintISBN 978-1-61721-108-9 PDFExcept as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical,
4、photocopying, recording, or otherwise, without the prior written permission of the publisher.ANSI/SMACNA 0052013Round Industrial Duct Construction Standards Third Edition iiiFOREWORDThese duct construction standards are intended for use by contractors, fabricators, and designers of air pollution con
5、-trol, pneumatic conveyance, and industrial ventilation systems.Changes in the Third Edition The changes in this edition are relatively minor; generally refl ecting clarifi cations based on contractors technical inquiries, and three main changes as described below:In the Duct Materials chapter, Alum
6、inized Steel was added including a description of its unique corrosion and heat resistant characteristics, available thicknesses, and common uses.In the Duct Selection Tables for Carbon and Galvanized chapter, it was assumed that the yield strength and modulus of elasticity of carbon steel remains r
7、elatively constant from ambient to the maximum recommended design temperature of 650 F (345 C). However, the reality is that both strength characteristics drop a few percent, and while this effect is more signifi cant in the design of rectangular duct, it was decided that for the sake of consistency
8、, the temperature correction factors established for rectangular industrial duct be adopted for round industrial as well. An analysis of the impact of this strength reduction reveals that in the over-whelming majority of cases there is no change in selected gage thickness from the previous edition.
9、The reason for this is that when selecting duct material, we compare the calculated metal thickness to the equiva-lent decimal thickness of the selected gage, and since the selected gage must exceed the required thickness, the excess thickness offsets the increase required by the drop in metal stren
10、gth. In the data of all the duct selection tables, only one case out of hundreds, required change to a heavier gage over the previous edition.The other signifi cant change is in the duct selection tables for Aluminum. Whereas aluminum sheet thickness has traditionally been based on the Brown and Sha
11、rp gage; for a number of years now, both manufacturers and users of aluminum identify sheet thickness by the decimal equivalent of the same Brown and Sharp gage. To simplify ordering material the aluminum tables have been updated from gage number to its decimal equivalent (nominal thickness), while
12、calculations are still based on the minimum decimal thickness from the Brown and Sharp gage (See Table 37).Users of this standard should note that, as with the use of the term “duct“, the term “pipe” can be used when indicating conveyance of air between two points. The term “pipe” originated in foun
13、dries and pneumatic conveying applications for industrial environments, and historically the terminology of “pipe” and “duct” have been used interchangeably. Likewise, theses terms have been used interchangeably within the scope of the SMACNA Round Industrial Duct Construction Standard.Changes in th
14、e Second Edition The 1977 edition of these standards was the fi rst publication dealing with the selection of duct gage and reinforcing systems for industrial duct applications. While the fi rst edition served industry very well for many years, technology has continued to move forward, and the Indus
15、trial Task Force of SMACNA has responded to our memberships request to expand and update the original text. We are taking their request one step further by restructuring the manual and providing supportive software to make the design process more “user friendly.” One of the main considerations in th
16、e development of the new standards is the opportunity to create a software program for personal computers that can greatly expand the computational capability of the user and permits an almost unlimited examination of different con-struction details and design solutions. A comprehensive review of th
17、e old procedures was completed and modifi cations implemented to update the technology and make the design procedures compatible with the computerization effort.While the new procedures include many of the same assumptions as the original work, a number of new features have been added:Microsoft Wind
18、ows based calculation software to expedite selection of construction details (software sold separately)iv Round Industrial Duct Construction Standards Third EditionFour different types of carbon steel and two different types of galvanized steelSeven different types of stainless steel alloysFour diff
19、erent types of aluminum alloysDesign capability for high temperature systems up to 800F (427C), and higher with design review by a specialized professionalConsideration of wind, snow, ice, and maintenance loadsExpanded tables to include ducts to 96 in. (2440 mm)Expanded tables to include material up
20、 to in. (12.7 mm) thicknessAll data presented in both English (InchPound) and Metric (SI) unitsExpanded data for the selection of duct supportsChapter on the use of spiral lockseam pipe in industrial applicationsAccepted industry practice for round industrial ductsNew Duct Class 5 for systems handli
21、ng corrosivesNew chapter on weldingNew guide specifi cation for the fabrication and installation of industrial duct systemsChapter of practical examples with step- by- step calculation instructionsChapter of fl ow charts to guide the user in design processThe Industrial Task Force is greatly indebte
22、d to Dr. Michael C. Soteriades, who did the original work for the fi rst edition and also provided the professional consultation and analysis necessary for the development of this new and expanded publication.SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC.Round Industrial Duc
23、t Construction Standards Third Edition vROUND INDUSTRIAL DUCT CONSTRUCTION TASK FORCEThe SMACNA Round Industrial Duct Construction Task Force develops and maintains standards for the design and construction of industrial ventilation and air pollution control systems.Ken Groeschel, Jr., P.E., Chairma
24、nButters Fetting Co.Malone, WisconsinRussell BoweAllied Blower update the theoretical basis for design; improve the presentation to make the expanded publica-tion more “user friendly;” to cover both the simple, low or moderate temperature and pressure indoor systems, as well as the more complex outd
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIROUNDINDDUCTCONSTSTDS2013ROUNDINDUSTRIALDUCTCONSTRUCTIONSTANDARDSTHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-437881.html