ANSI NEMA SG-IPRM 1-2016 Smart Grid Interoperability Process Reference Manual.pdf
《ANSI NEMA SG-IPRM 1-2016 Smart Grid Interoperability Process Reference Manual.pdf》由会员分享,可在线阅读,更多相关《ANSI NEMA SG-IPRM 1-2016 Smart Grid Interoperability Process Reference Manual.pdf(56页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA SG-IPRM 1-2016Smart Grid Interoperability Process Reference ManualApproved as an American National Standard ANSI Approval Date: February 22, 2016 NEMA Standards Publication SG-IPRM 1-2016 Smart Grid Interoperability Process
2、Reference Manual Published by National Electrical Manufacturers Association 1300 North 17thStreet, Suite 900 Rosslyn, VA 22209 www.nema.org 2016 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, t
3、he Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. 2016 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of perso
4、ns engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and
5、guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA ad
6、ministers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and gui
7、deline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA discla
8、ims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the
9、 performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to per
10、form any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other s
11、tandards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document.
12、NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the cert
13、ifier or maker of the statement. ANSI/NEMA SG-IPRM 1-2016 Page i 2016 National Electrical Manufacturers Association CONTENTS Foreword iv Section 1 General . 1 1.1 Scope 1 1.2 References . 1 1.2.1 Normative References . 1 1.2.2 Other References 2 1.3 Definitions 3 1.4 Abbreviations and Acronyms. 6 1.
14、5 Nomenclature . 7 Section 2 Background . 8 2.1 Problem Statement 8 2.2 Smart Grid Product Testing Flow Model . 8 2.3 Intended Audience 9 Section 3 Foundation Reference Standards 11 3.1 Overview of ISO/IEC 17025 . 11 3.2 Overview of ISO/IEC 17065 . 12 Section 4 ITCA Implementation of the IPRM 13 4.1
15、 What is an ITCA? . 13 4.2 ITCAs and Available Industry Testing and Certification Programs . 13 4.3 Stakeholder Relationships . 14 Section 5 Interoperability and Conformance Test Program Construction 15 5.1 General Test Policies 15 5.2 Test Suite Specification 17 5.3 Attributes of a Test Profile in
16、lieu of Complete TSS 19 5.4 ITCA Technical Program Design 19 5.5 Program and Field Experience Feedback . 22 Section 6 Interoperability Certification Body and Test Laboratory Requirements . 23 6.1 Certification Bodies and Test Laboratories 23 6.2 Governance 23 6.3 Laboratory Qualification . 25 6.4 Im
17、provements 25 Section 7 Additional Issues Impacting Interoperability 27 7.1 Cybersecurity . 27 7.2 Electromagnetic Compatibility Considerations . 28 ANSI/NEMA SG-IPRM 1-2016 Page ii 2016 National Electrical Manufacturers Association ANNEX A Cybersecurity Testing (Informative) 29 A.1 Cybersecurity Co
18、ncepts . 29 A.2 Cybersecurity Testing Environment 29 A.3 Cybersecurity Testing Types and Frameworks 29 A.4 Additional Cybersecurity Testing Laboratory Best Practices to Consider . 31 A.5 Role of the Cybersecurity Testing Providers . 32 A.6 Cybersecurity Requirements and Recommendations . 33 ANNEX B
19、Electromagnetic Compatibility Testing (Informative) 34 B.1 Introduction 34 B.2 Incidences of EMC Immunity Problems 35 B.3 EMC Phenomena . 35 B.4 Typical Immunity/Emissions Tests 36 B.5 Test Plan . 37 B.6 Perform Tests and Determine if Product Passes . 37 B.7 Performance Degradation . 37 B.8 EMC Requ
20、irements and Recommendations . 38 ANNEX C Frequently Asked Questions (Informative) . 39 ANSI/NEMA SG-IPRM 1-2016 Page iii 2016 National Electrical Manufacturers Association TABLES Table 1 General Test Policy Requirements and Recommendations . 16 Table 2 Test Suite Specification Requirements and Reco
21、mmendations 17 Table 3 Test Profile Requirements and Recommendations . 19 Table 4 ITCA Technical Program Design Requirements and Recommendations 19 Table 5 Governance Requirements and Recommendations 23 Table 6 Improvement Requirements and Recommendations 25 Table 7 Cybersecurity Requirements and Re
22、commendations . 33 Table 8 EMC Requirements and Recommendations . 38 FIGURES Figure 1 Smart Grid Product Testing FlowProposed Model . 9 Figure 2 Relationships between ITCAs, Certifiers, Test Labs, Accreditors, and SGTCC . 14 Figure 3 Typical EMC Investigation Process . 34 ANSI/NEMA SG-IPRM 1-2016 Pa
23、ge iv 2016 National Electrical Manufacturers Association Foreword (This foreword is not part of ANSI/NEMA SG-IPRM 1-2016) The Interoperability Process Reference Manual, or IPRM, is a key foundational element of the Smart Grid Interoperability Panel (SGIP). The SGIP Smart Grid Testing and Certificati
24、on Committee (SGTCC) developed and issued the IPRM to detail its recommendations on testing and certification processes and best practices that enhance the introduction of interoperable products in the market place. These recommendations build upon international standards-based processes for interop
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSINEMASGIPRM12016SMARTGRIDINTEROPERABILITYPROCESSREFERENCEMANUALPDF

链接地址:http://www.mydoc123.com/p-437657.html