ANSI ISO ASTM 52628-2013 Standard Practice for Dosimetry in Radiation Processing.pdf
《ANSI ISO ASTM 52628-2013 Standard Practice for Dosimetry in Radiation Processing.pdf》由会员分享,可在线阅读,更多相关《ANSI ISO ASTM 52628-2013 Standard Practice for Dosimetry in Radiation Processing.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、ISO/ASTM 52628:2013(E)Standard Practice forDosimetry in Radiation Processing1This standard is issued under the fixed designation ISO/ASTM 52628; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last revision.INTRODUCTION
2、The use of ionizing radiation for the treatment of commercial products such as the sterilization ofmedical devices, the reduction of microbial contamination in food or the modification of polymers isreferred to as radiation processing. The types of radiation used may be gamma radiation (typicallyfro
3、m cobalt-60 sources), X-radiation or accelerated electrons.It is necessary to ensure that the specified absorbed dose is applied in each of the radiationprocessing applications. The absorbed dose must be measured, and measurement systems have beendeveloped for this purpose. Much of the development o
4、f these systems rests on the early developmentof dosimetry systems for personnel radiation protection and for medical treatment. However, theabsorbed doses used in radiation processing are generally higher, ranging from 10 Gy up to 100 kGyor more and new dosimetry systems have been developed for mea
5、surements of these doses.Note that the terms “dose” and “absorbed dose” are used interchangeably in this standard (see3.1.1).The dose measurements required in radiation processing concern characterization of radiationfacilities in installation qualification (IQ) and operational qualification (OQ), m
6、easurement of dosedistribution in irradiated products in performance qualification (PQ) and routine monitoring of theirradiation process.The literature is abundant with articles on dosimeters for radiation processing, and guidelines andstandards have been written by several organizations (the Intern
7、ational Atomic Energy Agency(IAEA) and the International Commission on Radiation Units and Measurements (ICRU), forexample) for the operation of the dosimetry systems and for their use in the characterization andvalidation of the radiation processing applications. In particular, ICRU Report 80 provi
8、des informationon the scientific basis and historical development of many of the systems in current use.ASTM Subcommittee E10.01 on Radiation Processing: Dosimetry and Applications was formed in1984 initially with the scope of developing standards for food irradiation, but its scope was widenedto in
9、clude all radiation processing applications. The subcommittee, now Committee E61, has under itsjurisdiction approximately 30 standard practices and standard guides, collectively known as the E61standards on radiation processing. A number of these standards have been published as ISO/ASTMstandards, t
10、hereby ensuring a wider international acceptance. These practices and guides describe thedosimetry systems most commonly used in radiation processing, and the dose measurements that arerequired in the validation and routine monitoring of the radiation processes. A current list of the E61standards on
11、 radiation processing is given in 2.1 and 2.2.The development, validation and routine control of a radiation process comprises a number ofactivities, most of which rely on the ability to measure the delivered dose accurately. It is thereforenecessary that dose is measured with traceability to nation
12、al, or international, standards, and theuncertainty is known, including the effect of influence quantities. The E61 standards on radiationprocessing dosimetry serve to fulfill these requirements.The practices describing dosimetry systems have several common attributes, and there is a need tohave one
13、 general standard that can act as a common reference and that can be used as a basis for theselection of dosimetry systems for defined tasks. ISO/ASTM Practice 52628 serves this purpose. Itoutlines general requirements for the calibration and use of dosimetry systems and for the estimationof measure
14、ment uncertainties. Details relating to each dosimetry system are found in the respectivestandards and each of these refer to ISO/ASTM Practice 52628 for the general requirements. ISO/ASTM International 2017 All rights reservedThis international standard was developed in accordance with internationa
15、lly recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.11. Scope1.1 This practice describes the basic requireme
16、nts that applywhen making absorbed dose measurements in accordance withthe ASTM E61 series of dosimetry standards. In addition, itprovides guidance on the selection of dosimetry systems anddirects the user to other standards that provide specific infor-mation on individual dosimetry systems, calibra
17、tion methods,uncertainty estimation and radiation processing applications.1.2 This practice applies to dosimetry for radiation process-ing applications using electrons or photons (gamma- orX-radiation).1.3 This practice addresses the minimum requirements of ameasurement management system, but does n
18、ot include generalquality system requirements.1.4 This practice does not address personnel dosimetry ormedical dosimetry.1.5 This practice does not apply to primary standard dosim-etry systems.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. I
19、t is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Reference documents2.1 ASTM Standards:2E170 Terminology Relating to Radiation Measurements andDosimetryE1026 Practice f
20、or Using the Fricke Dosimetry SystemE2232 Guide for Selection and Use of Mathematical Meth-ods for Calculating Absorbed Dose in Radiation Process-ing ApplicationsE2303 Guide for Absorbed-Dose Mapping in RadiationProcessing FacilitiesE2304 Practice for Use of a LiF Photo-Fluorescent FilmDosimetry Sys
21、temE2381 Guide for Dosimetry in Radiation Processing ofFluidized Beds and Fluid Streams (Withdrawn 2016)3E2449 Guide for Irradiation of Pre-packaged ProcessedMeat and Poultry Products to Control Pathogens andOther Microorganisms (Withdrawn 2016)3F1355 Guide for Irradiation of FreshAgricultural Produ
22、ce asa Phytosanitary TreatmentF1356 Guide for Irradiation of Fresh, Frozen or ProcessedMeat and Poultry to Control Pathogens and Other Micro-organismsF1736 Guide for Irradiation of Finfish and Aquatic Inverte-brates Used as Food to Control Pathogens and SpoilageMicroorganismsF1885 Guide for Irradiat
23、ion of Dried Spices, Herbs, andVegetable Seasonings to Control Pathogens and OtherMicroorganisms2.2 ISO/ASTM Standards:251205 Practice for Use of a Ceric-Cerous Sulfate DosimetrySystem51261 Practice for Calibration of Routine Dosimetry Sys-tems for Radiation Processing51275 Practice for Use of a Rad
24、iochromic Film DosimetrySystem51276 Practice for Use of a Polymethylmethacrylate Dosim-etry System51310 Practice for Use of a Radiochromic Optical Wave-guide Dosimetry System51401 Practice for Use of a Dichromatic Dosimetry System51431 Practice for Dosimetry in Electron Beam and X-Ray(Bremsstrahlung
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISOASTM526282013STANDARDPRACTICEFORDOSIMETRYINRADIATIONPROCESSINGPDF

链接地址:http://www.mydoc123.com/p-437124.html