ANSI ISO ASTM 51940-2013 Standard Guide for Dosimetry for Sterile Insect Release Programs.pdf
《ANSI ISO ASTM 51940-2013 Standard Guide for Dosimetry for Sterile Insect Release Programs.pdf》由会员分享,可在线阅读,更多相关《ANSI ISO ASTM 51940-2013 Standard Guide for Dosimetry for Sterile Insect Release Programs.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、ISO/ASTM 51940:2013(E)Standard Guide forDosimetry for Sterile Insect Release Programs1This standard is issued under the fixed designation ISO/ASTM 51940; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last revision.1.
2、Scope1.1 This guide outlines dosimetric procedures to be fol-lowed for the radiation-induced reproductive sterilization oflive insects for use in pest management programs. The primaryuse of such insects is in the Sterile Insect Technique, wherelarge numbers of reproductively sterile insects are rele
3、ased intothe field to mate with and thus control pest populations of thesame species. A secondary use of sterile insects is as benignhosts for rearing insect parasitoids. The procedures outlined inthis guide will help ensure that insects processed with ionizingradiation from gamma, electron, or X-ra
4、y sources receiveabsorbed doses within a predetermined range. Information oneffective dose ranges for specific applications of insectsterilization, or on methodology for determining effective doseranges, is not within the scope of this guide.NOTE 1Dosimetry is only one component of a total quality a
5、ssuranceprogram to ensure that irradiated insects are adequately sterilized and fullycompetitive or otherwise suitable for their intended purpose.1.2 This guide provides information on dosimetry for theirradiation of insects for these types of irradiators: self-contained dry-storage137Cs or60Co irra
6、diators, self-containedlow-energy X-ray irradiators (maximum processing energiesfrom 150 to 300 keV), large-scale gamma irradiators, andelectron accelerators (electron and X-ray modes).NOTE 2Additional, detailed information on dosimetric procedures tobe followed in installation qualification, operat
7、ional qualification, perfor-mance qualification, and routine product processing can be found inISO/ASTM Practices 51608 (X-ray bremsstrahlung facilities processingat energies over 300 keV), 51649 (electron beam facilities), 51702(large-scale gamma facilities), and 52116 (self-contained dry-storagega
8、mma facilities), and in Ref (1)2(self-contained X-ray facilities).1.3 The absorbed dose for insect sterilization is typicallywithin the range of 20 to 600 Gy.1.4 This guide refers, throughout the text, specifically toreproductive sterilization of insects. It is equally applicable toradiation sterili
9、zation of invertebrates from other taxa (forexample,Acarina, Gastropoda) and to irradiation of live insectsor other invertebrates for other purposes (for example, induc-ing mutations), provided the absorbed dose is within the rangespecified in 1.3.1.5 This guide also covers the use of radiation-sens
10、itiveindicators for the visual and qualitative indication that theinsects have been irradiated.1.6 This document is one of a set of standards that providesrecommendations for properly implementing and utilizingdosimetry in radiation processing and describes a means ofachieving compliance with the re
11、quirements ofASTM PracticeE2628. It is intended to be read in conjunction with ASTME2628.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practice
12、s and determine the applica-bility of regulatory limitations prior to use.2. Referenced documents2.1 ASTM Standards:3E170 Terminology Relating to Radiation Measurements andDosimetryE2303 Guide for Absorbed-Dose Mapping in RadiationProcessing FacilitiesE2628 Practice for Dosimetry in Radiation Proces
13、singE2701 Guide for Performance Characterization of Dosim-eters and Dosimetry Systems for Use in Radiation Pro-cessing2.2 ISO/ASTM Standards:351261 Practice for Calibration of Routine Dosimetry Sys-tems for Radiation Processing51275 Practice for Use of a Radiochromic Film DosimetrySystem51310 Practi
14、ce for Use of a Radiochromic Optical Wave-guide Dosimetry System51539 Guide for the Use of Radiation-Sensitive Indicators51607 Practice for Use of an Alanine-EPR Dosimetry Sys-tem1This guide is under the jurisdiction of ASTM Committee E61 on RadiationProcessing and is the direct responsibility of Su
15、bcommittee E61.04 on SpecialtyApplication, and is also under the jurisdiction of ISO/TC 85/WG 3.Current edition approved Dec. 26, 2012. Published April 2013. Originallypublished as ASTM E 194098. Last previous ASTM edition E 194098. Thepresent International Standard ISO/ASTM 51940:2013(E) replaces A
16、STM E194098 and is a major revision of the last previous edition ISO/ASTM51940:2004(E).2The boldface numbers in parentheses refer to the bibliography at the end of thisstandard.3For referenced ASTM and ISO/ASTM standards, visit the ASTM website,www.astm.org, or contact ASTM Customer Service at servi
17、ceastm.org. ForAnnual Book of ASTM Standards volume information, refer to the standardsDocument Summary page on the ASTM website. ISO/ASTM International 2017 All rights reservedThis international standard was developed in accordance with internationally recognized principles on standardization estab
18、lished in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.151608 Practice for Dosimetry in an X-Ray (Bremsstrahlung)Facility for Radiation Processing51649 Practice
19、for Dosimetry in an Electron Beam Facilityfor Radiation Processing at Energies Between 300 keVand 25 MeV51702 Practice for Dosimetry in a Gamma Facility forRadiation Processing51707 Guide for Estimating Uncertainties in Dosimetry forRadiation Processing51956 Practice for Use of Thermoluminescence-Do
20、simetry(TLD) Systems for Radiation Processing52116 Practice for Dosimetry for a Self-Contained Dry-Storage Gamma-Ray Irradiator2.3 International Commission on Radiation Units and Mea-surements (ICRU) Reports:4ICRU 85a Fundamental Units and Quantities for IonizingRadiation2.4 ISO Standards:5ISO/IEC 1
21、7025 General Requirements for the Competenceof Testing and Calibration Laboratories2.5 Joint Committee for Guides in Metrology (JCGM)Reports:JCGM 100:2008, GUM, with minor corrections, Evaluationof measurement data Guide to the Expression ofUncertainty in Measurement6JCGM 100:2008, VIM International
22、 vocabulary of metrol-ogy Basis and general concepts and associated terms73. Terminology3.1 Definitions:3.1.1 absorbed dose (D)quantity of ionizing radiationenergy imparted per unit mass of a specified material. The SIunit of absorbed dose is the gray (Gy), where 1 gray isequivalent to the absorptio
23、n of 1 joule per kilogram of thespecified material (1 Gy = 1 J/kg). The mathematical relation-ship is the quotient of d by dm, where d is the meanincremental energy imparted by ionizing radiation to matter ofincremental mass dm (see ICRU 85a).D 5 d/dm3.1.1.1 DiscussionThe discontinued unit for absor
24、beddose is the rad (1 rad = 100 erg/g = 0.01 Gy). Absorbed doseis sometimes referred to simply as dose.3.1.2 absorbed-dose mappingmeasurement of absorbed-dose within an irradiated product to produce a one-, two- orthree-dimensional distribution of absorbed dose, thus renderinga map of absorbed-dose
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISOASTM519402013STANDARDGUIDEFORDOSIMETRYFORSTERILEINSECTRELEASEPROGRAMSPDF

链接地址:http://www.mydoc123.com/p-437121.html