1、ISO/ASTM 51540:2004 (Reapproved 2012)(E)Standard Practice forUse of a Radiochromic Liquid Dosimetry System1This standard is issued under the fixed designation ISO/ASTM 51540; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year
2、 of last revision.1. Scope1.1 This practice covers the procedures for preparation,handling, testing, and using radiochromic liquid dosimetrysystems of radiochromic dye solutions held in sealed or cappedcontainers (for example, ampoules, vials). It also covers the useof spectrophotometric or photomet
3、ric readout equipment formeasuring absorbed dose in materials irradiated by photonsand electrons.1.2 This practice applies to radiochromic liquid dosimetersolutions that can be used within part or all of the specifiedranges as follows:1.2.1 The absorbed dose range is from 0.5 to 40 000 Gy forphotons
4、 and electrons.1.2.2 The absorbed dose rate is from 103to 1011Gy/s.1.2.3 The radiation energy range for photons is from 0.01 to20 MeV.1.2.4 The radiation energy range for electrons is from 0.01to 20 MeV.NOTE 1Since electrons with energies less than 0.01 MeV may notpenetrate the container of the solu
5、tion, the solutions may be stirred in anopen beaker with the electrons entering the solutions directly (1).21.2.5 The irradiation temperature range is from 40 to+60C.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of t
6、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced documents2.1 ASTM Standards:3C912 Practice for Designing a Process for Cleaning Techni-cal GlassesE170 Terminology Relating to Radiatio
7、n Measurements andDosimetryE275 Practice for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersE666 Practice for Calculating Absorbed Dose From Gammaor X RadiationE668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining AbsorbedDose i
8、n Radiation-Hardness Testing of Electronic DevicesE925 Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidthdoes not Exceed 2 nmE958 Practice for Estimation of the Spectral Bandwidth ofUltraviolet-Visible SpectrophotometersE1026 Practice for Using
9、 the Fricke Dosimetry System2.2 ISO/ASTM Standards:351261 Guide for Selection and Calibration of DosimetrySystems for Radiation Processing51400 Practice for Characterization and Performance of aHigh-Dose Gamma Radiation Dosimetry CalibrationLaboratory51707 Guide for Estimating Uncertainties in Dosim
10、etry forRadiation Processing2.3 International Commission on Radiation Units and Mea-surements (ICRU) Reports:4ICRU Report 14 Radiation Dosimetry: X-Rays and GammaRays with Maximum Photon Energies Between 0.6 and 50MeVICRU Report 17 Radiation Dosimetry: X-Rays Generated atPotentials of 5 to 150 kV1Th
11、is practice is under the jurisdiction of ASTM Committee E61 on RadiationProcessing and is the direct responsibility of Subcommittee E61.02. on , and is alsounder the jurisdiction of ISO/TC 85/WG 3.Current edition approved March 21, 2012. Published November 2012. Originallypublished as E 1540 93. Las
12、t previous ASTM edition E 1540981. ASTME 154093 was adopted by ISO in 1998 with the intermediate designation ISO15565:1998(E). The present International Standard ISO/ASTM51540:2004(2012)(E) replaces ISO 15565 and is a reapproval of the last previousedition ISO/ASTM 51540:2004(E).2The boldface number
13、s in parentheses refer to the bibliography at the end of thispractice.3For referenced ASTM and ISO/ASTM standards, visit the ASTM website,www.astm.org, or contact ASTM Customer Service at serviceastm.org. ForAnnual Book of ASTM Standards volume information, refer to the standardsDocument Summary pag
14、e on the ASTM website.4Available from the International Commission on Radiation Units andMeasurements, 7910 Woodmont Ave., Suite 800, Bethesda, MD 20814, U.S.A. ISO/ASTM International 2017 All rights reservedThis international standard was developed in accordance with internationally recognized prin
15、ciples on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1ICRU Report 34 The Dosimetry of Pulsed RadiationICRU Report 35 Radiation D
16、osimetry: Electron Beams withEnergies between 1 and 50 MeVICRU Report 37 Stopping Powers for Electrons and PhotonsICRU Report 44 Tissue Substitutes in Radiation Dosimetryand MeasurementICRU Report 60 Fundamental Quantities and Units forIonizing Radiation3. Terminology3.1 Definitions:3.1.1 calibratio
17、n curvegraphical representation of the do-simetry systems response function.3.1.2 dosimeter batchquantity of dosimeters made from aspecific mass of material with uniform composition, fabricatedin a single production run under controlled, consistent condi-tions and having a unique identification code
18、.3.1.3 dosimetry systemsystem used for determining ab-sorbed dose, consisting of dosimeters, measurement instru-ments and their associated reference standards, and proceduresfor the systems use.3.1.4 measurement quality assurance plandocumentedprogram for the measurement process that ensures on acon
19、tinuing basis that the overall uncertainty meets the require-ments of the specific application. This plan requires traceabilityto, and consistency with, nationally or internationally recog-nized standards.3.1.5 molar linear absorption coeffcient (m)constant re-lating the spectrophotometric absorbanc
20、e, A, of an opticallyabsorbing molecular species at a given wavelength () per unitpathlength (d) to the molar concentration, c, of that species insolution (2-4): m=A/(dc). SI Unit: m2mol1.3.1.6 net absorbance, Achange in measured optical ab-sorbance at a selected wavelength determined as the absolut
21、edifference between the pre-irradiation absorbance, A0, and thepost-irradiation absorbance, A, as follows (2, 3): A=|AA0|.3.1.7 radiochromic liquid dosimeterspecially prepared so-lution containing ingredients that undergo change in opticalabsorbance under ionizing radiation. This change in opticalab
22、sorbance can be related to absorbed dose in water.3.1.8 response functionmathematical representation of therelationship between dosimeter response and absorbed dose fora given dosimetry system.3.1.9 specific net absorbance (k)Net absorbance, A,ata selected wavelength divided by the optical pathlengt
23、h, d,through the dosimeter material as follows: k=A/d.3.2 Definitions of other terms used in this standard thatpertain to radiation measurement and dosimetry may be foundin ASTM Terminology E170. Definitions in E170 are compat-ible with ICRU 60; that document, therefore, may be used as analternative
24、 reference.4. Significance and use4.1 The radiochromic liquid dosimetry system provides ameans of measuring absorbed dose in materials (5-7). Underthe influence of ionizing radiation, chemical reactions takeplace in the radiochromic solution modifying the amplitudes ofoptical absorption bands (8-10)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISOASTM515402004STANDARDPRACTICEFORUSEOFARADIOCHROMICLIQUIDDOSIMETRYSYSTEMPDF

链接地址:http://www.mydoc123.com/p-437113.html