1、INTERNATIONAL STANDARD ISO/IEC 10373-l First edition 1998-12-15 Identification cards - Test methods - Part 1: General characteristics tests Cartes didentification - Mkthodes dessai - Pat-tie 1: Essais des caractkristiques g b) a measuring device with a precision of 2,5 pm; c) a load of 2,2 N * 0,2 N
2、 (0.495 Ibf f 0.045 Ibf). 5.2.2.2 Procedure Pre-condition the sample card according to 4.2 before testing and conduct the test under the test environment defined in 4.1. Place the sample card on the level horizontal rigid surface and flatten it under the load. Measure the height and width of the car
3、d. 5.2.2.3 Test report The test report shall state whether the card conforms to the base standard and shall record the maximum and minimum values of height and width recorded. 6 0 ISOAEC lSO/lEC 10373-l :1998(E) 5.3 Peel strength The purpose of this test is to measure the peel strength* between card
4、 layers (see ISO/IEC 7810:1995). 5.3.1 Apparatus The following items are required: a) sharp cutting knife; b) pressure sensitive adhesive filament (fibre reinforced) tape or a suitable clamp; c) tensile tester equipped with chart recorder or equivalent; d) gripping device; e) (if required) stabilisi
5、ng plate backed with adhesive or adhesive tape and meeting the following requirements: 1) the adhesive strength shall be sufficient to ensure that the plate and card do not separate during testing; 2) the plate shall not bend during the measurement; 3) the size of the plate shall be equal to, or gre
6、ater than, the size of the card. EXAMPLE - A suitable plate might be a 60 mm x 90 mm x 2 mm aluminium plate backed with adhesive tape. 5.3.2 Procedure Pre-condition the sample card according to 4.2 before testing and conduct the test under the test environment defined in 4.1. Cut the card, or score
7、through the layer, to produce sections of width 10 mm + 0,l mm (0.39 in + 0.04 in) as shown in figure 3. * Note that ISO/IEC 7810:1995 defines delamination resistance in terms of a quantity called peel strength that, although similar in principle to that measured here, is not directly comparable. Th
8、e anomaly will be corrected at the next revision of ISO/IEC 7810. A revised requirement of 0,35 N/mm (2.0 lb/in), measured according to this method, is anticipated. 7 ISOAEC 10373-l :1998(E) 0 ISOAEC not to scale dimensions in millimetres top reference edge z- I I *, . . . . . . . . . . . . . . . .
9、. . . . . . . . . . . . . . . . . . . . . . . . . I test section 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . test section 2 ,. I test section 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10、. . . . . . . . . . . test section 4 I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -_-a. Figure 3 - Card preparation Using a sharp knife, cut the layer back from the core approximately 10 mm (0.4 in) and apply the clamp or adhesive ta
11、pe to the cut back edge of the layer and core as shown in figure 4. not to scale dimensions in millimetres apply clamp or adhesive tape Figure 4 - Specimen preparation for peel test If the peeling angle cannot be kept at 90” during the measurement, attach the stabilising plate to the core in advance
12、. Place the prepared specimen in the tensile tester fixture as shown in figure 5. The card shall be fixed on the apparatus. 8 0 ISOAEC ISOAEC 10373-l :1998(E) not to scale II Backing Plate J CYhesive I 10 mm (0.39 in) diameter rollers 1 mm (0.039 in) gap between rollers Adhesive tape loop Gripper Fi
13、gure 5 - Specimen mounted in tensile tester Operate the tensile tester according to the manufacturers instructions at 300 mm/min (11.8 in/min) to determine the peel strength in N (Ibf). Excluding the first and last 5 mm and any features less than 1 mm in length (spikes) from consideration, find the
14、test strip having the lowest peel strength value, using figure 6 as a guide. Record this as the measured peel strength for the card. NOTE - Dimensions shown in figure 6 are dimensions on the card. not to scale dimensions in millimetres spike minimum value urn measurement area 1 5 5 measurement area
15、5 I A A + /I Figure 6 - Examples of peel strength chart recordings 9 ISOAEC 10373-1:1998(E) 0 ISOAEC 5.3.3 Test report The test report shall give the measured peel strength, together with the test strip identifier. It shall also include the chart recording, clearly showing where the recorded minumum
16、 value was found, and shall state whether any tearing occurred. 5.4 Resistance to chemicals The purpose of this test is to determine any adverse effects of a range of chemical contaminants on a card test sample (see ISOAEC 7810:1995, ISOAEC 781 l-2:1 995, ISOAEC 7811-6:1996 and ISOAEC 11694-3:1995).
17、 5.4.1 Reagents 5.4.1 .l Solutions for short term contamination test a) aqueous solution of sodium chloride (NaCI, 98% minimum assay); b) aqueous solution of acetic acid (CHJOOH, 99% minimum assay); c) aqueous solution of sodium carbonate (Na,CO, 99% minimum assay); d) aqueous solution of ethyl alco
18、hol (CH,CH,OH, grain alcohol, 93% minimum assay); e) aqueous solution of sucrose (C,H,O, 98% minimum assay); f) Fuel 6 (according to IS0 1817:1985); g) aqueous solution of ethylene glycol (HOCH,CH,OH, 98% minimum assay). 5.4.1.2 Solutions for long term contamination a) salt mist; b) artificial persp
19、iration (both solutions shall be prepared in accordance with IS0 105-E04:1994), 1) alkaline solution, 2) acid solution. 5.4.2 Procedure Use a different sample card for each test. Pre-condition the sample card according to 4.2 before testing and conduct the test under the test environment defined in
20、4.1. Subject the each card to a visual inspection to establish its appearance prior to test and record the results of that examination. Perform any pre-exposure measurements required by the base standard. For cards with a magnetic stripe, record each sample card3 at 20 ft/mm (500 ftpi) using a test
21、recording current of I, read and note the signal amplitude. Expose the card to the appropriate short term or long term contamination described in 5.4.2.1 and 5.4.2.2. Immediately after removal from the solution, wash the card in distilled water and dry it with absorbent tissue. 3 Due to an error, th
22、e base standard may specify incorrect test recording conditions. 10 0 ISOAEC lSO/lEC 10373-1:1998(E) Perform any post-exposure measurements required by the base standard. For cards with a magnetic stripe, read the signal amplitude on the apparatus used for the pre-exposure measurements and compare t
23、he result with the amplitude obtained at the beginning of the test. Subject the card to a visual inspection to determine the effects of the test on its appearance and record the results of that examination. 5.4.2.1 Short term contamination Submerge the card for 1 min in one of the solutions listed i
24、n 5.4.1.1 which shall be kept at a temperature between 20C and 25C. 5.4.2.2 Long term contamination Expose the sample card to salt mist (see 5.4.1.2) for 24 h while mounted vertically in a cabinet in accordance with IS0 9227:1990. Submerge the sample card in each artificial perspiration solution (se
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIINCITSISOIEC1037311998IDENTIFICATIONCARDSTESTMETHODSPART1GENERALCHARACTERISTICSTESTSPDF

链接地址:http://www.mydoc123.com/p-435993.html