ANSI IEEE 11073-10406-2011 Health informatics Personal health device communication Part 10406 Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG)《健康信息学.个人保健装置通信.pdf
《ANSI IEEE 11073-10406-2011 Health informatics Personal health device communication Part 10406 Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG)《健康信息学.个人保健装置通信.pdf》由会员分享,可在线阅读,更多相关《ANSI IEEE 11073-10406-2011 Health informatics Personal health device communication Part 10406 Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG)《健康信息学.个人保健装置通信.pdf(73页珍藏版)》请在麦多课文档分享上搜索。
1、 Part 10406: Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG) Sponsored by the IEEE 11073 Standards Committee IEEE 3 Park Avenue New York, NY 10016-5997 USA 30 November 2011 IEEE Engineering in Medicine and Biology Society IEEE Std 11073-10406-2011Health informaticsPersonal he
2、alth device communication IEEE Std 11073-10406TM-2011 Health informaticsPersonal health device communication Part 10406: Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG) Sponsor IEEE 11073TMStandards Committee of the IEEE Engineering in Medicine and Biology Society Approved 10
3、 September 2011 IEEE-SA Standards Board Approved 12 December 2012 American National Standards Institute Abstract: Within the context of the ISO/IEEE 11073 family of standards for device communication, a normative definition of the communication between personal basic electrocardiograph (ECG) devices
4、 and managers (e.g., cell phones, personal computers, personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability is established in this standard. Appropriate portions of existing standards including ISO/IEEE 11073 terminology and IEEE 11073-20601 informati
5、on models are leveraged. The use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability is specified. A common core of communication functionality for personal telehealth basic ECG (1- to 3-lead ECG) devices i
6、s defined. Monitoring ECG devices are distinguished from diagnostic ECG equipment with respect to including support for wearable ECG devices, limiting the number of leads supported by the equipment to three, and not requiring the capability of annotating or analyzing the detected electrical activity
7、 to determine known cardiac phenomena. This standard is consistent with the base framework and allows multifunction implementations by following multiple device specializations (e.g., ECG and respiration rate). Keywords: basic electrocardiograph (ECG) (1- to 3-lead ECG), IEEE 11073-10406, medical de
8、vice communication, personal health devices The Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue, New York, NY 10016-5997, USA Copyright 2011 by the Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 30 November 2011. Printed in the United Sta
9、tes of America. IEEE is a registered trademarks in the U.S. Patent +1 978 750 8400. Permission to photocopy portions of any individual standard for educational classroom use can also be obtained through the Copyright Clearance Center. iv Copyright 2011 IEEE. All rights reserved Introduction This int
10、roduction is not part of IEEE Std 11073-10406-2011, Health informaticsPersonal health device communicationPart 10406: Device specializationBasic electrocardiograph (ECG) (1- to 3-lead ECG). Within the context of the ISO/IEEE 11073 family of standards for device communication, this standard establish
11、es a normative definition of the communication between personal basic electrocardiograph (ECG) devices and managers (e.g., cell phones, personal computers, personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability. It leverages appropriate portions of exi
12、sting standards including ISO/IEEE 11073 terminology and IEEE 11073-20601 information models. It specifies the use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability. This standard defines a common core of
13、 communication functionality for personal telehealth basic ECG (1- to 3-lead ECG) devices. Monitoring ECG devices are distinguished from diagnostic ECG equipment with respect to including support for wearable ECG devices, limiting the number of leads supported by the equipment to three, and not requ
14、iring the capability of annotating or analyzing the detected electrical activity to determine known cardiac phenomena. This standard is consistent with the base framework and allows multifunction implementations by following multiple device specializations (e.g., ECG and respiration rate). Notice to
15、 users Laws and regulations Users of these documents should consult all applicable laws and regulations. Compliance with the provisions of this standard does not imply compliance to any applicable regulatory requirements. Implementers of the standard are responsible for observing or referring to the
16、 applicable regulatory requirements. IEEE does not, by the publication of its standards, intend to urge action that is not in compliance with applicable laws, and these documents may not be construed as doing so. Copyrights This document is copyrighted by the IEEE. It is made available for a wide va
17、riety of both public and private uses. These include both use, by reference, in laws and regulations, and use in private self-regulation, standardization, and the promotion of engineering practices and methods. By making this document available for use and adoption by public authorities and private
18、users, the IEEE does not waive any rights in copyright to this document. Updating of IEEE documents Users of IEEE standards should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of amendments, corri
19、genda, or errata. An official IEEE document at any point in time consists of the current edition of the document together with any amendments, corrigenda, or errata then in effect. In order to determine whether a given document is the current edition and whether it has been amended through the issua
20、nce of amendments, corrigenda, or errata, visit the IEEE Standards Association web site at http:/ieeexplore.ieee.org/xpl/standards.jsp, or contact the IEEE at the address listed previously. v Copyright 2011 IEEE. All rights reserved For more information about the IEEE Standards Association or the IE
21、EE standards development process, visit the IEEE-SA web site at http:/standards.ieee.org/. Errata Errata, if any, for this and all other standards can be accessed at the following URL: http:/standards.ieee.org/findstds/errata/index.html. Users are encouraged to check this URL for errata periodically
22、. Interpretations Current interpretations can be accessed at the following URL: http:/standards.ieee.org/findstds/interps/index.html. Patents Attention is called to the possibility that implementation of this standard may require use of subject matter covered by patent rights. By publication of this
23、 standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. The IEEE is not responsible for identifying Essential Patent Claims for which a license may be required, for conducting inquiries into the legal validity or scope of Patents Claims
24、 or determining whether any licensing terms or conditions provided in connection with submission of a Letter of Assurance, if any, or in any licensing agreements are reasonable or non-discriminatory. Users of this standard are expressly advised that determination of the validity of any patent rights
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIEEE11073104062011HEALTHINFORMATICSPERSONALHEALTHDEVICECOMMUNICATIONPART10406DEVICESPECIALIZATIONBASICELECTROCARDIOGRAPHECG1TO3LEADECG

链接地址:http://www.mydoc123.com/p-435220.html