ANSI FM 4474-2004 Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and or Negative Differential Pressures.pdf
《ANSI FM 4474-2004 Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and or Negative Differential Pressures.pdf》由会员分享,可在线阅读,更多相关《ANSI FM 4474-2004 Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and or Negative Differential Pressures.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ANSI FM 4474-2004 (R2010) January 2011 2011 FM Approvals LLC. All rights reserved. FM Approvals Foreword NOTE: This foreword is introductory
2、 only and is not part of American National Standard FM 4474. This standard is intended to verify that the product as described will meet minimum specific stated conditions of performance, safety and quality, useful in determining the potential suitability for end-use conditions of these products. It
3、 describes minimum performance requirements for materials that are intended for use in roof assemblies by evaluating the ability of the materials and, in turn, the system components to withstand simulated wind uplift resistance. This American National Standard has been developed according to the ess
4、ential requirements of due process for standards development of the American National Standards Institute (ANSI). FM Approvals is an ANSI-accredited standards developer (ASD). ANSI/FM 4474 was originally published in March 2004 and re-affirmed in January 2011. No changes have been made. Approval of
5、an American National Standard requires verification by ANSI that the principles of openness and due process have been followed and that a consensus of those directly and materially affected by the standard has been achieved. Consensus requires that all views and objections be considered, and that a
6、concerted effort be made toward their resolution. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached. The American National Standards Institute does not develop standards nor will it in any circumstances give an interpretation
7、 of any American National Standard. Requests for interpretations of this test standard should be addressed to FM Approvals. ANSI regulations require that this American National Standard shall be revised, reaffirmed or withdrawn within five years of the date of publication. FM Approvals 1151 Boston-P
8、rovidence Turnpike P. O. Box 9102 Norwood, MA 02062 U. S.A. Phone: 781-762-4300 Fax: 781-762-9375 E-mail: A FM Approvals TABLE OF CONTENTS 1. INTRODUCTION 1 1.1 Purpose . 1 1.2 Scope 1 1.3 Basis for Requirements 1 1.4 System of Units . 1 2 GENERAL INFORMATION . 3 2.1 Product Information . 3 2.2 Requ
9、irements . 3 3 APPLICABLE DOCUMENTS AND GLOSSARY 4 3.1 Applicable Documents . 4 3.2 Glossary 4 4 GENERAL REQUIREMENTS . 6 4.1 General 6 4.2 Markings . 6 4.3 Simulated Wind Uplift Resistance Ratings 6 4.4 Roof Assembly Component Requirements 6 5 PERFORMANCE REQUIREMENTS 7 5.1 General 7 5.2 Conditions
10、 of Acceptance . 7 APPENDIX A: UNITS OF MEASUREMENT . 9 APPENDIX B: SIMULATED WIND UPLIFT PULL TEST PROCEDURE . 10 B-1 Introduction 10 B-2 Design of the Test Apparatus 10 B-3 Test Sample 10 B-4 Conduct of Test 11 B-5 Results 12 APPENDIX C: 5 9 SIMULATED WIND UPLIFT PRESSURE TEST PROCEDURE 13 C-1 Int
11、roduction 13 C-2 Design of the Test Apparatus . 13 C-3 Test Sample 14 C-4 Conduct of Test 14 C-5 Results 15 APPENDIX D: 12 24 SIMULATED WIND UPLIFT PRESSURE TEST PROCEDURE . 16 D-1 Introduction . 16 D-2 Design of the Test Apparatus 16 D-3 Test Sample 17 D-4 Conduct of Test 17 D-5 Results 18 D-6 Alte
12、rnate Test Methods . 18 D-7 Design of the Test Apparatus 18 D-8 Conduct of Test 19 D-9 Results 21 _ANSI FM 4474-2004(R2010) FM Approvals 1 1. INTRODUCTION 1.1 Purpose This standard states the test requirements for evaluating the simulated wind uplift resistance of roof assemblies by using static pos
13、itive and/or negative differential pressures. The standard applies to all components as assembled in the roof system. 1.2 Scope 1.2.1 Roof components, incorporated in complete roof assemblies, are exposed to various wind conditions. This standard presents test methods to evaluate the simulated wind
14、uplift resistance of the completed roof assembly by using static positive and/or negative differential pressures. 1.2.2 This standard applies to a complete roof assembly. Weatherability, leakage, hail, fire resistance, corrosion resistance of fasteners and aggregate blow-off potential are not a part
15、 of this evaluation. 1.2.3 The performance of a roof assembly depends in part on all components in the roof system and on how they interact. It is therefore necessary to evaluate the roof assembly as a whole when measuring the potential for its wind resistance classification. 1.2.4 This standard is
16、intended to evaluate only those hazards investigated, and is not intended to determine suitability for the end use of a product. 1.2.5 This standard is intended to be used to determine the simulated wind uplift resistance of the following types of roof assemblies: assemblies that utilize mechanical
17、fasteners, adhesives, hot asphalt, heat welding, self adhesive components or combination thereof, to secure insulations, base sheets, cap sheets, exterior coverings and other components, in single or multi-layered constructions, to one another and to the roof deck assemblies that utilize structural
18、concrete, lightweight insulating concrete, cementitious wood fiber or gypsum roof decks having a minimum thickness of 2 in. (51 mm) assemblies that utilize fiber reinforced cement roof decks having a minimum thickness of 4 in. (102 mm) assemblies that utilize steel, wood or fiber reinforced plastic
19、roof decks standing/lap seam metal roof systems 1.2.6 This standard is not intended to be used to evaluate loose laid ballasted roof assemblies. 1.3 Basis for Requirements The requirements of this standard are based on experience, research and testing and/or the standards of other organizations. The
20、 advice of manufacturers, users, trade associations and loss control specialists was also considered. 1.4 System of Units Units of measurement are U.S. customary units. These are followed by their arithmetic equivalents in International System (SI) units, enclosed in parentheses. Appendix A lists so
21、me of the selected units used in testing these products; conversions to SI units are included. Conversion of U.S. customary units is in accordance with ANSI/IEEE/ASTM SI 10-97, Standard for Use of the International System of Units (SI): _ANSI FM 4474-2004(R2010) FM Approvals 2 The Modern Metric Syst
22、em. _ANSI FM 4474-2004(R2010) FM Approvals 3 2 GENERAL INFORMATION 2.1 Product Information Roof assemblies are usually comprised of a roof deck, insulation and roof covering. They are often constructed by first securing rigid insulation boards to the top surface of the deck with insulation fasteners
23、, fastener plates or adhesives. A weatherproof covering is then installed above the insulation. Some assemblies are permitted to incorporate vapor retarders and/or air barriers. Vapor retarders and air barriers are permitted to be placed directly on the deck with fasteners driven through the insulat
24、ion and vapor retarder and/or air barrier, in conjunction with sandwich-style construction, i.e., adhered over insulation board which has been attached to the deck with insulation fasteners or adhesive prior to applying a second layer of insulation, or in conjunction with a mechanically fastened bas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIFM44742004EVALUATINGTHESIMULATEDWINDUPLIFTRESISTANCEOFROOFASSEMBLIESUSINGSTATICPOSITIVEANDORNEGATIVEDIFFERENTIALPRESSURESPDF

链接地址:http://www.mydoc123.com/p-434790.html