ANSI FCI 99-2-2015 Pressure Reducing Regulator Capacity.pdf
《ANSI FCI 99-2-2015 Pressure Reducing Regulator Capacity.pdf》由会员分享,可在线阅读,更多相关《ANSI FCI 99-2-2015 Pressure Reducing Regulator Capacity.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/FCI 99-2-2015 AMERICAN NATIONAL STANDARD PRESSURE REDUCING REGULATOR CAPACITY Fluid Controls Institute, Inc. Sponsor: Fluid Controls Institute, Inc. 1300 Sumner Ave Cleveland, Ohio 44115-2851 iiANSI/FCI 99-2-2015 AMERICAN NATIONAL STANDARD Pressure Reducing Regulator Capacity Sponsor Fluid Con
2、trols Institute, Inc. AmericanNationalStandardAmerican National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an America
3、n National Standard does not in any respect preclude anyone, whether he has approved the standard or not, from manufacturing, marketing, purchasing or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cau
4、tioned to obtain the latest editions. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the dat
5、e of publication. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Sponsored and published by: FLUID CONTROLS INSTITUTE, INC. 1300 Sumner Avenue Cleveland, OH 44115-2851 Phn: 216/241-7333 Fax:
6、216/241-0105 E-Mail: fcifluidcontrolsinstitute.org URL: www.fluidcontrolsinstitute.org Copyright 2015 by Fluid Controls Institute, Inc. All Rights Reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission
7、of the publisher. Suggestions for improvement of this standard will be welcome. They should be sent to the Fluid Controls Institute, Inc. Printed in the United States of America iiiivCONTENTS PAGE Foreword .v 1. Purpose .1 2. Scope 1 3. Definitions 1-2 4. Test Method . 2-4 5. References . 4 vForewor
8、d (This foreword is included for information only and is not part of ANSI/FCI 99-2-2015, Pressure Reducing Regulator Capacity) This voluntary standard has been compiled by the Regulator Section of the Fluid Controls Institute, Inc. It has been developed to provide a test methodology for measuring an
9、d reporting the capacity of pilot operated and direct acting pressure reducing regulators. The standard was originally approved in 2004. The section reaffirmed the standard. FCI recognizes the need to periodically review and update this standard. Suggestions for improvement should be forwarded to th
10、e Fluid Controls Institute, Inc., 1300 Sumner Avenue, Cleveland, Ohio 44115-2851. All constructive suggestions for expansion and revision of this standard are welcome. The existence of a Fluid Controls Institute (FCI) standard does not in any respect preclude any member or non-member from manufactur
11、ing or selling products not conforming to this standard nor is the FCI responsible for its use. Please go to the FCI web site for all of the latest technical articles and standards. 1ANSI/FCI 99-2-2015 AMERICAN NATIONAL STANDARD Pressure Reducing Regulator Capacity 1. PURPOSE This standard creates a
12、 guideline for establishing and reporting regulator capacities for use by manufacturers, users, specifiers and approval bodies in order to promote consistent presentation of regulator capacities. 2. SCOPE To provide a test methodology for measuring and reporting the capacity of pilot operated and di
13、rect acting pressure reducing regulators. 3. DEFINITIONS 3.1 Accuracy of Regulation. The deviation from the set point, expressed as a percentage or as a fixed unit, taken at the test conditions. 3.2 Controlled Variable. The variable which shall be monitored by the controlling process. This variable
14、is either the outlet pressure or the differential pressure. 3.3 Lockup (Dead End Shutoff). The deviation of the controlled variable from set point obtained at a no flow condition. 3.4 Maximum Capacity. The flow rate at maximum travel generally used for safety or relief valve sizing. 3.5 Maximum Cv.M
15、aximum Cvis Cv at maximum capacity calculated per ISA S75.01 generally used for safety relief valve sizing. 3.6 Minimum Controllable Flow. The lowest flow rate, at a given set point and temperature, at which a steady regulated condition of the controlled variable can be maintained. The minimum contr
16、ollable flow is essentially zero for some regulators. Minimum controllable flow is used to determine turndown or rangeability. 3.7 Offset. The deviation of the controlled variable measured as the flow varies from the minimum controllable flow to the rated capacity. Offset is sometimes referred to as
17、 droop for pressure reducing valves. 3.8 Rated Capacity. The rate of flow obtainable through a regulator, for specified inlet and outlet conditions and fluid, at a specified offset or accuracy of regulation. 3.9 Rated Cv. Rated Cv is measured at rated capacity as calculated per ISA S75.01. 3.10 Rate
18、d Rangeability (Turndown). The rated capacity divided by the minimum controllable flow, usually expressed as a percentage. 3.11 Set Flow. The flow rate used to obtain the set point, typically 5 to 10% of rated capacity. 3.12 Set Point. The regulator adjustment corresponding to the desired value of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIFCI9922015PRESSUREREDUCINGREGULATORCAPACITYPDF

链接地址:http://www.mydoc123.com/p-434786.html