1、 Dehumidifiers ANSI/AHAM DH-1-2008 p 2 ANSI/AHAM DH-1-2008 PREFACE The Association of Home Appliance Manufacturers develops standards in accordance with AHAMs “Policy and Procedures Governing Technical Standards“ which states: “AHAM Standards shall be in the best interest, mutually, of consumers who
2、 use appliances, the industries which provide and service appliances, and other interested parties. They shall relate to actual use conditions, be technically and scientifically sound.” Use or observance of AHAM standards is voluntary. AHAM standards are presented to the American National Standards
3、Institute (ANSI) for recognition as American National Standards. This standard was so recognized on May 9, 2008 and bears the American National Standard designation ANSI/AHAM DH-1-2008. This standard contains: Test procedures which may be applied to any brand or model of dehumidifier for measuring p
4、erformance. Results of tests in accordance with this standard may be publicly stated. Recommended levels of performance which are considered important to include but which, necessarily are recommendations only. With regard to safety, AHAM recommends that all appliance products-both major and portabl
5、e-manufactured or marketed in the United States be submitted to an appropriate independent laboratory for inspection and listing in conformance with the safety standards and procedures followed by such laboratories. The relevant standard for dehumidifiers is ANSI/UL 474, Dehumidifiers. AHAM welcomes
6、 comments and suggestions regarding this standard. Any standard may be reviewed and improved as needed. All standards must be updated or reconfirmed at least every five years. Any interested party, at any time, may request a change in an AHAM standard. Such request should be addressed to AHAMs Presi
7、dent, and should be accompanied by a statement of reason for the request and a suggested alternate proposal. When metric units are not specified, conversion from customary units should be done in accordance with the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASH
8、RAE) Metric Practice Guide, and the AHAM SI Metric Practice Guide for the Appliance Industry. Copyright 2008 by the Association of Home Appliance Manufacturers (AHAM) All rights reserved. The hard copy print version of this document shall be for individual use only. The electronic file version of th
9、is document shall be for storage on one computer for purposes of viewing and/or printing one copy for individual use only. This document shall not be reproduced in whole or in part by any means, and shall not be transmitted electronically or otherwise to a third person without the prior written perm
10、ission of AHAM. p 3 ANSI/AHAM DH-1-2008 CONTENTS Section Page 1. PURPOSE 4 2. SCOPE . 4 3. DEFINITIONS. 4 4. INSTRUMENTATION 4 5. TEST PROCEDURE 5 6. NAMEPLATE DATA 6 7. CAPACITY TEST AND ENERGY CONSUMPTION TEST 6 8. PERFORMANCE TESTS 9 9. SAFETY. 11 APPENDIX. 12 p 4 ANSI/AHAM DH-1-2008 1. PURPOSE T
11、his standard establishes a uniform, repeatable procedure for measuring the capacity and energy input of dehumidifiers under specified test conditions. The standard methods and the recommended levels of performance, where they appear, are intended to provide a means to compare and evaluate different
12、brands and models of dehumidifiers regarding characteristics significant to product use. The standard methods and recommended levels of performance, where they appear, are not intended to inhibit improvement and innovation in product testing, design or performance. 2. SCOPE This standard applies to
13、dehumidifiers as defined in 3.1 and includes definitions, performance test procedures, and safety. 3. DEFINITIONS 3.1 Self-Contained, Electrically-operated, Mechanically-Refrigerated Dehumidifier A self-contained, electrically operated, mechanically-refrigerated dehumidifier is an encased assembly c
14、onsisting of: (A) A refrigerated surface (evaporator) on which moisture from the atmosphere condenses. (B) A refrigerating system, including an electric motor. (C) An air circulating fan. (D) A drain arrangement for collecting and/or disposing of the condensate. 3.2 Capacity Capacity is a measure of
15、 the ability of a dehumidifier to remove moisture from its surrounding atmosphere. The capacity of a dehumidifier is the amount of water stated in pints collected per 24 hours of continuous operation when tested in accordance with Section 7.1, Capacity Test. 4. INSTRUMENTATION 4.1 Temperature Measur
16、ing Instruments Temperature measurements shall be made with an instrument or instrument system, including readout devices, meeting an accuracy of 0.1F (0.05C) and a precision (scale division) not greater than 0.2F (0.1C) for analog type instruments and 0.05F (0.02C) for digital type equipment. 4.2 P
17、sychrometric Instruments Use an aspirating type psychrometer air sampler with air flow over the sensing elements between 700 and 1,000 ft/min (3.5 and 5.1 m/s). Shield or position the psychrometer box to minimize radiation affects on the sensing elements. Refer to ASHRAE 41.1 for typical psychromete
18、r box design. p 5 ANSI/AHAM DH-1-2008 4.3 Electrical Measuring Instruments Electricity measurements shall be made with instruments having an accuracy of 0.5% of quantity measured with a minimum measurement increment not greater than: (A) Volts - 2.0 volts (B) Amps - 0.1 amperes (C) Watts - 5 watts (
19、D) Watt-hours - 1 watt-hour 4.4 Time Measuring Instruments Use time measuring instruments which are accurate to 0.1%. 4.5 Weight Measuring Instruments Use weight measuring instruments which are accurate to 0.5%. 4.6. Barometric Pressure Measuring Instrument Use a barometric pressure measuring instru
20、ment which is accurate to 0.3%. 5. TEST PROCEDURE 5.1 General Operate the dehumidifier in accordance with the manufacturers instructions insofar as possible. 5.2 Test Room The test room should be of sufficient volume and the air shall be circulated in such a manner that the normal air circulation of
21、 the dehumidifier under test is not affected. The test room shall be of such dimensions that the distance from any room surface to the air discharge side of the unit is at least 6 ft (1.83 m) and the distance from any other room surface is not less than 3 ft (0.91 m), except for the floor. The test
22、room conditioning equipment shall handle air at a rate of not less than 2 times the dehumidifiers airflow. The air flow approaching the test unit shall be uniform in temperature, humidity and velocity. The air velocity shall not exceed 50 ft/min (0.26 m/s) within 3 ft (0.91 m) of the dehumidifier wi
23、th the unit not operating. 5.3 Positioning of Test Unit Position the dehumidifier in the test room in accordance with Section 5.2, Test Room. Place the air sampling tree 1 ft (0.3 m) from the air inlet side of the dehumidifier, and shielded so that there will be no direct heat radiation to or from t
24、he other objects in the test room. The orientation of the test unit shall be such that the air flow through the test unit is in the same direction as the airflow within the test room. 5.4 Condensate Collection If means for collecting the condensate are provided as a part of the dehumidifier, they ar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIDH12008DEHUMIDIFIERSPDF