ANSI CTA-2034-A-2015 Standard Method of Measurement for In-Home Loudspeakers (Formerly ANSI CEA-2034-A).pdf
《ANSI CTA-2034-A-2015 Standard Method of Measurement for In-Home Loudspeakers (Formerly ANSI CEA-2034-A).pdf》由会员分享,可在线阅读,更多相关《ANSI CTA-2034-A-2015 Standard Method of Measurement for In-Home Loudspeakers (Formerly ANSI CEA-2034-A).pdf(60页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/CTA Standard Standard Method of Measurement for In-Home Loudspeakers ANSI/CTA-2034-A (Formerly ANSI/CEA-2034-A) February 2015 NOTICE Consumer Technology Association (CTA) Standards, Bulletins and other technical publications are designed to serve the public interest through eliminating misunde
2、rstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards, Bulletins and other technical publications
3、shall not in any respect preclude any member or nonmember of the Consumer Technology Association from manufacturing or selling products not conforming to such Standards, Bulletins or other technical publications, nor shall the existence of such Standards, Bulletins and other technical publications p
4、reclude their voluntary use by those other than Consumer Technology Association members, whether the standard is to be used either domestically or internationally. Standards, Bulletins and other technical publications are adopted by the Consumer Technology Association in accordance with the American
5、 National Standards Institute (ANSI) patent policy. By such action, the Consumer Technology Association does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard, Bulletin or other technical publication. This document does not purp
6、ort to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. This document
7、is copyrighted by the Consumer Technology Association and may not be reproduced, in whole or part, without written permission. Federal copyright law prohibits unauthorized reproduction of this document by any means. Organizations may obtain permission to reproduce a limited number of copies by enter
8、ing into a license agreement. Requests to reproduce text, data, charts, figures or other material should be made to the Consumer Technology Association. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.) Published by CONSUMER TECHNOLOGY ASSOCIATION 2015 Technology Phone +41 22
9、919 02 11; Fax +41 22 919 03 00; Internet http:/www.iec.ch 3.2 Informative References The following standards contain provisions that, through reference in this text, constitute informative provisions of this standard. At the time of publication, the editions indicated were valid. All standards are
10、subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards listed here. 5 ANSI/CEA-2034-A 3.2.1 Informative Reference List AES Convention Paper 5638, Characterizing the Amplitude Response o
11、f Loudspeaker Systems, presented at 113thAudio Engineering Society Convention October 2002, Allan Devantier CEA-490-A R-2008, Test Methods of Measurement for Audio Amplifiers IEC 60263 ed3.0 (1982-01), Scales and Sizes for Plotting Frequency Characteristics and Polar Diagrams IEC 60268-1 ed2.0 (1985
12、-01), Sound system equipment. Part 1: General IEC 60268-1-am1 ed2.0 (1988-01), Amendment 1 - Sound system equipment. Part 1: General IEC 60268-1-am2 ed2.0 (1988-01), Amendment 2 - Sound system equipment. Part 1: General IEC 60268-2 ed2.0 (1987-06), Sound system equipment. Part 2: Explanation of gene
13、ral terms and calculation methods IEC 60268-2-am1 ed2.0 (1991-05), Amendment 1 - Sound system equipment. Part 2: Explanation of general terms and calculation methods IEC 60268-5 ed3.1 Consol. with am1 (2007-09), Sound system equipment - Part 5: Loudspeakers NIST Special Publications 811 2008 Edition
14、, Guide for the use of the International System of Units universally abbreviated SI (from the French Le Systeme Intgernational dUnites) 3.2.2 Informative Reference Acquisition Audio Engineering Society (AES): http:/www.aes.org/e-lib/browse.cfm?elib=11234 CEA Standards: Techstreet, 3916 Ranchero Driv
15、e, Ann Arbor, MI, USA 48108; Phone 800-699-9277; Fax 734-780-2046; Internet http:/; Email IEC Standards: International Electrotechnical Commission, IEC Central Office, 3, rue de Varemb P.O. Box 131, CH - 1211 Geneva 20 Switzerland; Phone +41 22 919 02 11; Fax +41 22 919 03 00; Internet http:/www.ie
16、c.ch NIST Standards: National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-8930; Phone 301 975-6478; Internet http:/www.nist.gov/publication-portal.cfm Email inquiriesnist.gov 3.3 Definitions Continuous The root mean squared value of a signal over a one second inte
17、rval Normalized Transfer Function A transfer function measurement that has been referenced to (divided by) another transfer function measurement Peak The instantaneous maximum value, either positive or negative, of a signal Point of Rotation (POR) The point on the front baffle of the loudspeaker tha
18、t intersects the reference axis 6 ANSI/CEA-2034-A 3.4 Symbols and Abbreviations CF Crest Factor dB decibel DUT Device Under Test ERDI Early Reflections Directivity Index FFT Fast Fourier Transform HD+N Harmonic Distortion + Noise Hz hertz kHz kilohertz LFCS Low Frequency Calibration Source m meter M
19、IV Maximum Input Voltage Pa pascal PIR Predicted In-Room Amplitude Response POR Point of Rotation RCF Room Correction Factor rms Root Mean Square SPDI Sound Power Directivity Index SPL Sound Pressure Level Note: Throughout this document all references to “dB SPL” refer to sound pressure level refere
20、nced to 20 Pa. SPLMUCOSound Pressure Level Maximum Usable Continuous Output THD+N Total Harmonic Distortion + Noise V volt 3.5 Compliance Notation As used in this standard “shall” and “must” denote mandatory provisions of the standard. “Should” denotes a provision that is recommended but not mandato
21、ry. “May” denotes a feature whose presence does not preclude compliance, and implementation of which is optional. “Optional” denotes items that may or may not be present in a compliant device. 4 Test Setup and Conditions CAUTION WEAR EAR PROTECTION! High sound levels can cause hearing damage with pr
22、olonged exposure. The operator is advised to wear appropriate protection such as ear plugs, preferably balanced attenuation devices which will still permit the operator to listen critically for distortion or other signs of distress in the device under test. 4.1 General Test Setup and Conditions All
23、testing shall be conducted in an anechoic chamber or equivalent environment. During testing the DUT shall be operated as per manufacturers instructions. Complete systems shall be tested intact. Testing shall be conducted at an ambient temperature of 22 C 5 C (71.6 F 9 F) and relative humidity of 30
24、% to 80 %. If the conditions are different, they shall be noted at the time of the test. Both of these items shall be recorded at the time of the tests. The ambient atmospheric pressure (in Pascals) shall also be recorded. 7 ANSI/CEA-2034-A For powered loudspeakers the mains voltage used to power th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSICTA2034A2015STANDARDMETHODOFMEASUREMENTFORINHOMELOUDSPEAKERSFORMERLYANSICEA2034APDF

链接地址:http://www.mydoc123.com/p-434567.html