ANSI CSA AM IAS LC 2A-1998 DIRECT GAS-FIRED CIRCULATING HEATERS FOR AGRICULTURAL ANIMAL CONFINEMENT BUILDINGS (Addenda to the First Edition).pdf
《ANSI CSA AM IAS LC 2A-1998 DIRECT GAS-FIRED CIRCULATING HEATERS FOR AGRICULTURAL ANIMAL CONFINEMENT BUILDINGS (Addenda to the First Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI CSA AM IAS LC 2A-1998 DIRECT GAS-FIRED CIRCULATING HEATERS FOR AGRICULTURAL ANIMAL CONFINEMENT BUILDINGS (Addenda to the First Edition).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、DIRECT GAS-FIREDCIRCULATING HEATERS FORAGRICULTURAL ANIMALCONFINEMENT BUILDINGSANSI/IASLC 2a-1998INTERNATIONALAPPROVAL SERVICESA Division of CSA8501 East Pleasant Valley Rd.Cleveland, Ohio 44131Addenda toANSI/IAS LC 2-1996PREFACEThe standards set forth herein apply to the first edition of the Standa
2、rdfor Direct Gas-Fired Circulating Heaters for Agricultural Animal ConfinementBuildings, ANSI/IAS LC 2-1996, and supersede corresponding standards therein.Following their preparation by the supervising subcommittee, they were acceptedby Accredited Standards Committee Z21/83 and subsequently approved
3、 as anAmerican National Standard by the American National Standards Institute, Inc.NOTE: Changes, other than editorial, are denoted by a vertical line in themargin.ApprovedNovember 16, 1998AMERICAN NATIONALSTANDARDS INSTITUTE, INC.Copyright 1998International Approval ServicesPermission is granted to
4、 republish material herein in laws orordinances, and in regulations, administrative orders, or similar documentsissued by public authorities. Those desiring permission for other republicationshould consult International Approval Services at the address noted above.Addenda toAMERICAN NATIONAL STANDAR
5、D FORCIRCULATING HEATERS FOR AGRICULTURALANIMAL CONFINEMENT BUILDINGSPART ICONSTRUCTION1.9 IGNITION MEANS (SYSTEMS)1.9.1 Automatic gas ignition systems (see Part IV, Definitions) and components shall comply with theapplicable construction provisions of the Standard for Automatic Gas Ignition Systems
6、 andComponents, ANSI Z21.20 or Combination Gas Controls for Gas Appliances,ANSI Z21.78iiCGA 6.20, or other nationally recognized standards covering such components.Automatic gas ignition system timings (see Part IV, Definitions) established under the above|standard shall not exceed those shown in Ta
7、ble II.|1.11 MANUAL GAS VALVES(Former 1.11.3, deleted.)(Former 1.11.4 becomes 1.11.3, unchanged.)1.14 AUTOMATIC VALVES AND SAFETY SHUTOFF VALVES1.14.1 A safety shutoff valve, unless provided as part of a combination gas control as specified in 1.10,shall be provided to shut off the main burner gas a
8、nd the pilot gas, if applicable. (See 1.9.3).|1.15 GAS PRESSURE REGULATORS1.15.2 A gas pressure regulator shall comply with the applicable provisions of the Standard for GasAppliance Pressure Regulators, ANSI Z21.18iiCGA 6.3, or the Standard for Combination GasControls for Gas Appliances, ANSI Z21.7
9、8iiCGA 6.20, as applicable.1PART IIPERFORMANCE2.1 GENERAL2.1.4 Heaters shall be tested in three modes: with full air flow, with the air inlet restricted and withthe air outlet restricted, unless otherwise specified. For the second and third modes, restriction|shall be imposed until any further closu
10、re would cause the heater to shut down within fifteenminutes.2.4 COMBUSTIONA heater shall not produce a concentration of carbon monoxide in excess of 25 ppm in a sample|of the flue gases, or if the sample obtained is over 25 ppm, 0.04 percent in an air-free sample of|the combustion gases when tested
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便