ANSI BHMA A156.4-2013 DOOR CONTROLS - CLOSERS《门控制器.闭合器》.pdf
《ANSI BHMA A156.4-2013 DOOR CONTROLS - CLOSERS《门控制器.闭合器》.pdf》由会员分享,可在线阅读,更多相关《ANSI BHMA A156.4-2013 DOOR CONTROLS - CLOSERS《门控制器.闭合器》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/BHMA A156.4 - 2013 Revision of ANSI/BHMA A156.4 - 2008 AMERICAN NATIONAL STANDARD FOR DOOR CONTROLS - CLOSERS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. AMERICAN NATIONAL STANDARDS INSTITUTE Approved May 28 , 2013 2 AMERICAN NATIONAL STANDARD An American National Standard implie
2、s a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has app
3、roved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National S
4、tandard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards receiv
5、e current information on all standards by calling or writing the American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue New York, NY 10017 Copyright 2013 by the Builders Hardware Manufacturers Association, Inc. Not to be reproduced
6、 without specific authorization from BHMA Printed in the USA This Standard was first published in July 1980 by the Builders Hardware Manufacturers Association, Inc. It was entitled, “Standard 301 BHMA Product Standards Section C, Door Controls (Closers).” ANSI approval was secured under the Canvass
7、Method. BHMA was accredited on 21 March 1983 by ANSI as a sponsor using the Canvass Method, and continues to participate actively in the ANSI process. 3 FORWARD (This Forward is not a part of ANSI/BHMA A156.4-2013) The general classification of builders hardware includes a wide variety of items whic
8、h are divided into several categories. To recognize this diversity, a sectional classification systems has been established. Door Controls is one such section and this Standard is the result of the collective efforts of members of the Builders Hardware Manufacturers Association, Inc., who manufactur
9、e this product. The total Product Standards effort is, therefore, a collection of sections, each covering a specific category of items. Performance tests and, where it has been necessary, dimensional requirements have been established to insure safety, security and stability to which the public is e
10、ntitled. There are no restrictions on design, except for those dimensional requirements imposed for the reasons given above. It is also required that some hardware items fit certain specified cutout dimensions. The BHMA recognizes that errors will be found, items will become obsolete, and new produc
11、ts, methods and materials will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. In most cases, products have been described in grade levels related to performance. Grade classifications indicate levels only with their own catego
12、ry. Choice of grade and specific product are made on the basis of utility, aesthetics, security objectives and end use desired. The BHMA numbers and pictorials which indicate types of hardware do not identify size, finish, material or options and are not intended to be used without necessary supplem
13、entary information. Consult individual manufacturers catalog. 4 Table of Contents 1. SCOPE . 5 2. GENERAL . 5 3. PREPARATION FOR PERFORMANCE TEST . 6 4. TEST PROCEDURES Part 1: INITIAL STATIC TESTS 8 5. TEST PROCEDURES PART 2: INTERMEDIATE CYCLE TEST 15 6. TEST PROCEDURES PART 3: INTERIM STATIC TEST
14、S . 16 7. TEST PROCEDURES PART 4: FINAL CYCLE TEST 16 8. TEST PROCEDURE PART 5: FINAL STATIC TESTS. 18 9. PIVOT PERFORMANCE TESTS 19 10. FINISH TESTS 20 11. TYPICAL ILLUSTRATION AND IDENTIFYING TYPE NUMBERS . 21 APPENDIX A: Users Guide (not a part of ANSI/BHMA A156.4) . 33 5 1. SCOPE 1.1 This Standa
15、rd contains requirements for door closers surface mounted, concealed in the door, overhead concealed and concealed in the floor. Also included are pivots for floor closers. Criteria for conformance include cycle, operational, closing force and finish tests. Optional tests which shall be specified se
16、parately are also included. 1.2 Tests in this Standard are performed under neutral air pressure laboratory conditions and between 60 and 85 degrees F. In actual usage results vary because of installation, maintenance, and environmental conditions. Actual closer performance is affected by fluctuating
17、 ambient conditions such as wind and pressure differentials, consult factory for recommendations. 1.3 Use on Fire Doors A door closer used on labeled fire door assemblies shall be listed or labeled by a nationally recognized independent testing laboratory, and be subject to a periodic in-plant follo
18、w-up service. Consult the authority having jurisdiction for the appropriate fire test requirements. 2. GENERAL 2.1 Reference to other Standards. ANSI Standards referenced in this Standard are available from the American National Standards Institute, www.ansi.org, and . 2.2 Type Numbers This Standard
19、 has been prepared to standardize door closers and controls by type requirements and performance levels. Only those type numbers shown in this Standard shall be used. For explanation of identifying numbers, see 11.14. 2.3 Manufacturers Catalogs Consult manufacturers catalogs for construction details
20、 and special conditions relating to accessories. 2.4 Tolerances All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances: Number of cycles shall be minimum. Linear dimensions shall be + 1/16 in. (1.6 mm). Pounds or pound force shall b
21、e + 2%. The scribed lines for degree of opening shall be within + 2 degrees. A tolerance of + 2 degrees F shall be applied to temperature call outs. 2.5 SI Units All dimensions are expressed first in US units with SI unit (metric) equivalents given in parentheses. SI units are approximate. 2.6 All C
22、losers Door closers shall be categorized as listed in the following groupings by their performance requirements. Closer Description PT Number Surface or Concealed in Door closers, Grade 1 PT 1 Surface or Concealed in Door closers, Grade 2 PT 2 Surface or Concealed in Door closers, Grade 3 PT 3 Surfa
23、ce or Concealed in Door closers, Options PT 4-A,C,D,E,F,G,H,J Concealed Overhead and Floor Closers, Grade 1 PT 5 Concealed Overhead and Floor Closers, Grade 2 PT 6 Concealed Overhead and Floor Closers, Grade 3 PT 7 Concealed Overhead and Floor Closers, Options PT 8-A,B,C,D,E,F,G,J,K,L,M 2.7 Field Ap
24、plication Guidelines for closer sizing and door sizes are provided in the Appendix in Table A1. 6 2.8 Fluid To ensure better performance over a range of outdoor temperatures fluid used in door closers intended for exterior or vestibule door application shall have a pour point of minus 38 degrees F (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIBHMAA15642013DOORCONTROLSCLOSERS 门控 闭合 PDF

链接地址:http://www.mydoc123.com/p-434281.html