ANSI BHMA A156.38-2014 LOW ENERGY POWER OPERATED SLIDING AND FOLDING DOORS.pdf
《ANSI BHMA A156.38-2014 LOW ENERGY POWER OPERATED SLIDING AND FOLDING DOORS.pdf》由会员分享,可在线阅读,更多相关《ANSI BHMA A156.38-2014 LOW ENERGY POWER OPERATED SLIDING AND FOLDING DOORS.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/BHMA A156.38-2014 AMERICAN NATIONAL STANDARD FOR LOW ENERGY POWER OPERATED SLIDING AND FOLDING DOORS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. Approved by the American National Standards Institute August 15, 2014 2 AMERICAN NATIONAL STANDARD An American National Standard implie
2、s a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has appr
3、oved the Standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the Standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National St
4、andard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this Standard no later than five years from the date of publication. Purchasers of American National Standards receive
5、 current information on all Standards by calling or writing The American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue New York, New York 10017 Copyright 2014 by the Builders Hardware Manufacturers Association, Inc. Not to be reprod
6、uced without specific authorization from BHMA Printed in the USA This Standard was developed by the Builders Hardware Manufacturers Association, Inc. It was approved by ANSI under the Canvass Method. BHMA was accredited on 21 March 1983 as a sponsor using the Canvass Method. 3 FOREWORD (This Forewor
7、d is not a part of ANSI/BHMA A156.38) The general classification of builders hardware includes a wide variety of items which are divided into several categories. To recognize this diversity, a sectional classification system has been established. Power Operated Doors is one such section and this Sta
8、ndard is a result of the collective efforts of members of the Builders Hardware Manufacturers Association, Inc. who manufacture this product. The total Product Standards effort is, therefore, a collection of sections, each covering a specific category of items. Performance tests and, where necessary
9、, dimensional requirements have been established to ensure a degree of safety. There are no restrictions on design except for those dimensional requirements imposed for reasons of safety. This Standard is not intended to obstruct but rather to encourage the development of improved products, methods
10、and materials. The BHMA recognizes that errors will be found, items will become obsolete, and new products, methods and materials will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. It shall also be the responsibility of manuf
11、acturers to request such appropriate revisions. 4 TABLE OF CONTENTS 1. GENERAL .5 2. DEFINITIONS .6 3. REQUIREMENTS FOR LOW ENERGY POWER OPERATED SLIDING DOORS 7Error! Bookmark not defined. 4. REQUIREMENTS FOR LOW ENERGY POWER OPERATED FOLDING DOORS 7 5. CYCLE TESTS 8 6. SIGNS9 APPENDIX A (not a par
12、t of ANSI/BHMA A156.38) .9 5 1. GENERAL 1.1 Requirements in this Standard apply to low energy power operated sliding and folding door systems for pedestrian use, and some small vehicular use. The activation of all doors described in this standard requires a knowing act. Included are provisions inten
13、ded to reduce the chance of user injury or entrapment. 1.2 Doors that require higher speeds, forces, shorter time delays, and activating sensing devices shall comply with ANSI/BHMA A156.10 for Power Operated Pedestrian Doors and are not covered in A156.38. 1.3 This Standard does not attempt to asses
14、s any factors that exist with respect to custom design installations which are not required to meet the requirements of this Standard. 1.4 Unless otherwise specified, all references to time delay, opening speed and forces in this standard, refer to the operator in the power mode as opposed to the ma
15、nual mode. 1.5 Required dimensions are expressed in US units first and the SI (metric) equivalents given in parentheses are approximate. All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances: Linear dimensions shall be 1/16 in (1.6
16、 mm). Pounds or pound force shall be 5%. Angular measurements shall be 4 degrees. Voltage measurements shall be 5 percent. Temperature measurements shall be 4 degrees F ( 2 degrees C). 1.6 Compliance with the requirements of this standard shall be accomplished through factory settings or field adjus
17、tments as necessary. 1.7 Operators used on labeled fire door assemblies shall be listed or labeled by a nationally recognized independent testing laboratory, and be subject to a periodic in-plant follow-up service. Consult the authority having jurisdiction for the appropriate fire test requirements.
18、 1.8 Refer to applicable building codes for means of egress clear width requirements, and knowing act device locations. 6 2. DEFINITIONS 2.1 Low Energy Power Operated Door A door with a power mechanism that opens the door upon receipt of a knowing act activating signal, does not generate more kineti
19、c energy than specified in this Standard, and is closed by a power mechanism or by other means. 2.2 Clear Opening for Automatic Doors Single Sliding or Folding Doors - In the fully opened position, the clear opening is measured from the edge of the leading stile to the jamb or jamb stop if present.
20、Pair of Sliding or Folding Doors - In the fully opened position, the clear opening is measured between the edges of the leading stiles of the two doors. 2.3 Closing Cycle Movement of a sliding or folding door from the fully open position to the fully closed position. 2.4 Closing Time The time from t
21、he start of a door closing until it is fully closed. 2.5 Control A unit containing electrical components for automatic control of door operation. 2.6 Custom Installations Where an installation condition exists such that all of the performance criteria of this standard cannot be met. 2.7 Cycle The ac
22、tion of an automatic door operator starting with activating through opening and full closing of (a) door(s). 2.8 Face of Door The plane of the highest part of the door exposed to view when the door is closed. Does not include hardware or other applied products. 2.9 Finger Guard A device applied at t
23、he hinge stile of a door or to the hinge jamb adjacent to the door preventing damage to hands or fingers. 2.10 Folding Door A pivoted swing panel hinged to a passive panel, the other end of which is captured in a guide, thus allowing it to slide as both panels swing into a V shape (the fold). 2.11 K
24、nowing Act Consciously initiating the powered opening of a door. 2.12 Latch Check The checking or slowing down of the speed of closing a door before being fully closed. (Also called Close Check.) 7 3. REQUIREMENTS FOR LOW ENERGY POWER OPERATED SLIDING DOORS 3.1 Activation The activation shall be by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIBHMAA156382014LOWENERGYPOWEROPERATEDSLIDINGANDFOLDINGDOORSPDF

链接地址:http://www.mydoc123.com/p-434279.html