ANSI BHMA A156.23-2010 ELECTROMAGNETIC LOCKS《电磁锁的美国国家标准》.pdf
《ANSI BHMA A156.23-2010 ELECTROMAGNETIC LOCKS《电磁锁的美国国家标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI BHMA A156.23-2010 ELECTROMAGNETIC LOCKS《电磁锁的美国国家标准》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/BHMA A156.23-2010 Revision of BHMA A156.23-2004 AMERICAN NATIONAL STANDARD FOR ELECTROMAGNETIC LOCKS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. Approved by the American National Standards Institute August 20, 2010 2 AMERICAN NATIONAL STANDARD An American National Standard implies
2、 a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has appro
3、ved the Standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the Standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National Sta
4、ndard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards receive
5、current information on all standards by calling or writing The American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue, New York, New York, 10017 Copyright 2010 by the Builders Hardware Manufacturers Association, Inc. Not to be repro
6、duced without specific authorization from BHMA Printed in the USA This Standard was developed by the Builders Hardware Manufacturers Association, Inc. It was approved by ANSI under the canvass method. BHMA was accredited on 21 March 1983 as a sponsor using the Canvass Method. 3 FOREWORD (This Forewo
7、rd is not a part of ANSI/BHMA A156.23) The general classification of builders hardware includes a wide variety of items which are divided into several categories. To recognize this diversity, a sectional classification system has been established. Electromagnetic locks is one such section and this S
8、tandard is the result of the collective efforts of members of the Builders Hardware Manufacturers Association, Inc. who manufacture these products. The total product standards effort is therefore, a collection of sections, each covering a specific category of items. Strength, cycle, operational test
9、s and where it has been necessary, material and dimensional requirements have been established to insure safety and stability to which the public is entitled. There are no restrictions on design except for those dimensional requirements imposed for the reasons given above. This Standard is not inten
10、ded to obstruct but rather to encourage the development of improved products, methods and materials. The BHMA recognizes that errors will be found, items will become obsolete, and new products and methods will be developed. With this in mind the Association plans to update, correct and revise these
11、Standards on a regular basis. It shall also be the responsibility of manufacturers to request such appropriate revisions. The BHMA numbers which indicate functions of electromagnetic locks do not identify size or design and are not intended to be used without necessary supplementary information. Ind
12、ividual manufacturers catalogs should be consulted. 4 TABLE OF CONTENTS Section Page 1. SCOPE. 5 2. DEFINITIONS. 5 3. GENERAL 6 4. TEST METHODS . 6 5. STRENGTH TESTS . 7 6. ELECTRICAL TESTS 8 7. CYCLE TEST . 9 8. FINISH TESTS 10 9. EXPLANATION OF IDENTIFYING NUMBERS . 11 10. TYPICAL ILLUSTRATIONS, A
13、ND TYPE NUMBER DESCRIPTIONS 12 APPENDIX A (NOT A PART OF ANSI/BHMA A156.23) 15 5 1. SCOPE 1.1 This Standard establishes requirements for electromagnetic locks and includes cyclical, dynamic, operational, strength and finish tests. This product is used for access control. 1.2 Tests described in this
14、Standard are performed under laboratory conditions. In actual usage, results vary because of installation, maintenance, and environmental conditions. 2. DEFINITIONS 2.1 Electromagnetic Lock. An electrically powered lock. It locks or unlocks a door by the activation or deactivation of an electromagne
15、t coupled to an armature. 2.1.1 Direct Pull The mounting arrangement of an electromagnetic door lock whereby an opening force applied to the face of the door is directly opposed by the attraction of the magnet and armature along an axis perpendicular to the face of the door, which is obtained when t
16、he contact plane between magnet and armature is parallel to the door face. 2.1.2 Shear Lock The mounting arrangement of an electromagnetic door lock whereby the attraction between electromagnet and armature moves one or the other (usually the smaller armature) not only into contact with each other b
17、ut also into a position of mechanical restraint by a third member which prevents sliding separation (shear) of the magnet and armature along their contact plane. To unlock, the moving member is then retracted into its original resting position by mechanical, magnetic, gravitational, or other force.
18、2.2 Armature A plate attracted by the energized electromagnet component of the lock and when in contact with the magnet, resistant to being separated from the magnet. Also called a strike. 2.3 Indoor-Only Electromagnetic locks which are not suitable for continuous exposure to an outdoor environment.
19、 2.4 Rated Voltage The voltage in which the electromagnetic lock is to be used and the same voltage in which the electromagnetic lock is tested under section 5.1 Strength Test. 6 3. GENERAL 3.1 An electromagnetic lock shall be listed or labeled by a nationally recognized independent testing laborato
20、ry, and be subject to a periodic in-plant follow-up inspection service. 3.2 Tolerances. Where only minus tolerances are given, the dimensions are permitted to be exceeded at the option of the manufacturer. 3.3 Reference to other Standards. ANSI Standards are available from the American National Stan
21、dards Institute, 11 West 42nd Street, New York, NY 10036 or . 3.4 Values. Required values in this Standard are given in US units. The SI (metric) equivalents are approximate. 3.5 Codes. Electromagnetic locks are not permitted on some doors within a means of egress. Consult applicable building codes
22、and ANSI/NFPA 101 Life Safety Code. 3.6 Options. When specified, electromagnetic locks shall be equipped with one or more options (consult individual manufacturers catalogs). These shall consist of switches, special electronic circuits, or a combination of both that are utilized to monitor and indic
23、ate locked, unlocked or open door, and magnetic holding force. When supplied they shall be subject to tests as required in 5. 3.7 Use on Fire Doors. Electromagnetic locks used on labeled fire door assemblies shall be listed or labeled for fire doors by a nationally recognized independent testing lab
24、oratory, and be subject to a periodic in-plant follow-up inspection service. 3.8 Power Requirements. Electromagnetic locks shall be operated by direct (DC) or alternating (AC) current. Locks requiring power in excess of 30 VAC RMS (volts alternating current root mean square) or 42.5 VDC shall be sup
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIBHMAA156232010ELECTROMAGNETICLOCKS 电磁 美国 国家标准 PDF

链接地址:http://www.mydoc123.com/p-434260.html