ANSI AWWA D115-2017 Tendon-Prestressed Concrete Water Tanks.pdf
《ANSI AWWA D115-2017 Tendon-Prestressed Concrete Water Tanks.pdf》由会员分享,可在线阅读,更多相关《ANSI AWWA D115-2017 Tendon-Prestressed Concrete Water Tanks.pdf(92页珍藏版)》请在麦多课文档分享上搜索。
1、AWWA Standard SM Tendon-Prestressed Concrete Water Tanks Effective date: July 1, 2017. First edition approved by AWWA Board of Directors June 17, 1996. This edition approved Jan. 14, 2017. Approved by American National Standards Institute Feb. 17, 2017. ANSI/AWWA D115-17 (Revision of ANSI/AWWA D115-
2、06) Copyright 2017 American Water Works Association. All Rights Reserved. ii AWWA Standard This document is an American Water Works Association (AWWA) standard. It is not a specification. AWWA standards describe minimum requirements and do not contain all of the engineering and administrative inform
3、ation normally contained in specifications. The AWWA standards usually contain options that must be evaluated by the user of the standard. Until each optional feature is specified by the user, the product or service is not fully defined. AWWA pub- lication of a standard does not constitute endorseme
4、nt of any product or product type, nor does AWWA test, certify, or approve any product. The use of AWWA standards is entirely voluntary. This standard does not supersede or take precedence over or displace any applicable law, regulation, or code of any governmental authority. AWWA standards are inte
5、nded to represent a consensus of the water industry that the product described will provide satisfactory ser- vice. When AWWA revises or withdraws this standard, an official notice of action will be placed on the first page of the Official Notice section of Journal American Water Works Association.
6、The action becomes effective on the first day of the month following the month of Journal American Water Works Association publication of the official notice. American National Standard An American National Standard implies a consensus of those substantially concerned with its scope and provisions.
7、An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether that person has approved the standard or not, from manufacturing, marketing, purchasing,
8、 or using products, processes, or proce - dures not conforming to the standard. American National Standards are subject to periodic review, and users are cau- tioned to obtain the latest editions. Producers of goods made in conformity with an American National Standard are encouraged to state on the
9、ir own responsibility in advertising and promotional materials or on tags or labels that the goods are produced in conformity with particular American National Standards. Caution n oti Ce : The American National Standards Institute (ANSI) approval date on the front cover of this standard indicates c
10、ompletion of the ANSI approval process. This American National Standard may be revised or withdrawn at any time. ANSI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standard
11、s may receive current information on all standards by calling or writing the American National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036; 212.642.4900; or emailing infoansi.org. hours of work by your fellow water professionals. Revenue from the sales of this AWWA mat
12、erial supports ongoing product development. Unauthorized distribution, either electronic or photocopied, is illegal and hinders AWWAs mission to support the water community. This AWWA content is the product of thousands of ISBN-13, print: 978-1-62576-147-7 eISBN-13, electronic: 978-1-61300-372-5 DOI
13、: http:/dx.doi.org/10.12999/AWWA.D115.17 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information or retrieval system, except in the form of brief excerpts or quotations
14、 for review purposes, without the written permission of the publisher. Copyright 2017 by American Water Works Association Printed in USA Copyright 2017 American Water Works Association. All Rights Reserved. iii Committee Personnel The AWWA Standards Committee on Concrete Water Tanks, Tendon-Type Pre
15、stressed, which reviewed and approved this standard, had the following personnel at the time of approval: Terrence P. Kenyon, Chair General Interest Members C. Badger, Bates Engineering Inc., Lakewood, Colo. (AWWA) R.T. Bates,* Bates Engineering Inc., Lakewood, Colo. (AWWA) S.R. Close, Close Associa
16、tes LLC, Lakewood, Colo. (AWWA) T.P. Kenyon, Merrick and Company Inc., Denver, Colo. (AWWA) R. Kianoush, Ryerson University, Toronto, Canada (AWWA) F.S. Kurtz, Standards Engineer Liaison, AWWA, Denver, Colo. (AWWA) D. Larson, Standards Council Liaison, St. Louis, Mo. (AWWA) W.H. Peffley, Crawford, M
17、urphy (B) Separated DomeWall Connection . 27 4 Transfer of Tangential Shear From Wall to Base 38 5 Net Effective Base-Pad Width After Shear Deformation 42 Table 1 Response Modification Factor, R, for Type of Tank Base . 36 Copyright 2017 American Water Works Association. All Rights Reserved. vii For
18、eword This foreword is for information only and is not part of ANSI * /AW WA D115. I. Introduction. I.A. Background. The New England Water Works Association (NEWWA) established a committee in 1958 to prepare a standard for the design and construction of circular prestressed-concrete water storage ta
19、nks. The committee submitted a suggested specification covering wire-wound prestressed-concrete tanks to NEWWA in October 1962 as a guide to those water utilities that wished to consider the use of these tanks. The American Concrete Institute (ACI ) Committee 344 concluded eight years of committee w
20、ork with a report titled “Design and Construction of Circular Prestressed Concrete Structures,” published in the ACI Journal in September 1970. This report referred to both wire-wound and tendon tanks. After publication of its first report in 1970, ACI Committee 344 could not reach a consensus on a
21、combined report covering both wire-wound and tendon tanks. In 1985 the ACI Committee was divided into two subcommittees and “interim” reports were completed in 1988 for both types of tanks. ACI did not publish these interim reports but made copies available until a consensus could be reached on a re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAWWAD1152017TENDONPRESTRESSEDCONCRETEWATERTANKSPDF

链接地址:http://www.mydoc123.com/p-434131.html