ANSI AWWA B408-2018 Liquid Polyaluminum Chloride.pdf
《ANSI AWWA B408-2018 Liquid Polyaluminum Chloride.pdf》由会员分享,可在线阅读,更多相关《ANSI AWWA B408-2018 Liquid Polyaluminum Chloride.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/AWWA B408-18(Revision of ANSI/AWWA B408-10)AWWA StandardSMLiquid Polyaluminum ChlorideEffective date: May 1, 2018.First edition approved by AWWA Board of Directors Jan. 31, 1993.This edition approved Jan. 20, 2018.Approved by American National Standards Institute Sept. 28, 2017.Copyright 2018 A
2、merican Water Works Association. All Rights Reserved. iiAWWA StandardThis document is an American Water Works Association (AWWA) standard. It is not a specification. AWWA standards describe minimum requirements and do not contain all of the engineering and administrative information normally contain
3、ed in specifications. The AWWA standards usually contain options that must be evaluated by the user of the standard. Until each optional feature is specified by the user, the product or service is not fully defined. AWWA publication of a standard does not constitute endorsement of any product or pro
4、duct type, nor does AWWA test, certify, or approve any product. The use of AWWA standards is entirely voluntary. This standard does not supersede or take precedence over or displace any applicable law, regulation, or code of any governmental authority. AWWA standards are intended to represent a cons
5、ensus of the water industry that the product described will provide satisfactory service. When AWWA revises or withdraws this standard, an official notice of action will be placed in the Official Notice section of Journal - American Water Works Association. The action becomes effective on the first
6、day of the month following the month of Journal AWWA publication of the official notice.American National StandardAn American National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufact
7、urer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether that person has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the stand
8、ard. American National Standards are subject to periodic review, and users are cautioned to obtain the latest editions. Producers of goods made in conformity with an American National Standard are encouraged to state on their own responsibility in advertising and promotional materials or on tags or
9、labels that the goods are produced in conformity with particular American National Standards.Caution notiCe: The American National Standards Institute (ANSI) approval date on the front cover of this standard indicates completion of the ANSI approval process. This American National Standard may be re
10、vised or withdrawn at any time. ANSI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of ANSI approval. Purchasers of American National Standards may receive current information on all standards by calling or writing the Am
11、erican National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036; 212.642.4900; or e-mailing infoansi.org.ISBN-13, print: 978-1-62576-286-3 eISBN-13, electronic: 978-1-61300-467-8DOI: http:/dx.doi.org/10.12999/AWWA.B408.18All rights reserved. No part of this publication may
12、 be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information or retrieval system, except in the form of brief excerpts or quotations for review purposes, without the written permission of the publisher.Copyright 2018 by Ameri
13、can Water Works Association Printed in USACopyright 2018 American Water Works Association. All Rights Reserved. iiiCommittee PersonnelThe AWWA Standards Committee on Iron Salts, Aluminum Salts, and Related Coagulant Aids, which reviewed and approved this standard, had the following personnel at the
14、time of approval:Glenn R. Evers, ChairJan J. Pavlicek, Vice-ChairGeneral Interest MembersK.-K. Au, FMC Global Peroxychem, Naperville, Ill. B. Bickerton, CBCL Limited, Halifax, N.S., Canada N.J. Edman,*Standards Group Liaison, AWWA, Denver, Colo. J.D. Edwards, Westerville, Ohio G.R. Evers, IS2 LLC, H
15、ockessin, Del. J.J. Gemin, AECOM, Kitchener, Ont., Canada P.H. Hargette, Black spillage may cause a fire or liberate dangerous gases.3. Sodium chloride solution, standard, 0.05N. Dry approximately 3.1 g ofsodium chloride in a weighing dish in an oven at 105110C for 2 h. Cool the crystals to room tem
16、perature in a desiccator.Weigh 2.9221 g of the dried sodium chloride to the nearest 0.0001 g in a tared weighing bottle. Using a water-wash bottle, quantitatively transfer the crystals through a powder funnel into a 1,000-mL volumetric flask. Add about 150 mL deionized water and swirl to dissolve th
17、e crystals. Dilute to the mark at 20C with deionized water and mix thoroughly. Store the solution in a polyethylene bottle.4. Iron indicator solution. To a 1,500-mL beaker add 62 g ferric ammoniumsulfate, FeNH4(SO4)212H2O, and 500 mL of deionized water. Stir until the crystals are dissolved. Add 438
18、 mL concentrated nitric acid and mix. Store the solution in a polyethylene bottle.5. Potassium thiocyanate solution, 0.05N. Weigh 4.86 g potassiumthiocyanate to the nearest 0.01 g in a tared weighing bottle. Quantitatively transfer the crystals through a powder funnel into a 1,000-mL volumetric flas
19、k. Add about 250 mL deionized water and swirl to dissolve the crystals. Dilute to the mark with deionized water and mix thoroughly. Store the solution in a polyethylene bottle.Copyright 2018 American Water Works Association. All Rights Reserved. LIQUID POLYALUMINUM CHLORIDE 136. Benzyl alcohol. Disp
20、ense from an amber-glass dropping bottle.Caution: Benzyl alcohol vapor is irritating to the eyes, nose, and throat; the liquid can burn skin and eyes and also may be readily absorbed through the skin. It is combustible. Keep the reagent away from heat or flame.7. Silver nitrate solution, standard 0.
21、05N. Weigh 8.495 g silver nitrate tothe nearest 0.001 g in a tared weighing bottle. Quantitatively transfer the crystals through a powder funnel into a 1,000-mL volumetric flask. Add about 250 mL deionized water and swirl to dissolve the crystals. Dilute to the mark with deionized water and mix thor
22、oughly. Store the solution in a tightly stoppered amber-glass bottle. Standardize the solution as follows:a. Pipette 25.0 mL of the standard 0.05N sodium chloride solutioninto each of three 500-mL glass-stoppered Erlenmeyer flasks. Determine the temperature of the sodium chloride solution and correc
23、t the volume pipetted to 20C (Sec. 5.7.5Item 3 and Table 2). Carry each flask through the remaining steps of the procedure.Table 2 Temperature corrections for volumetric solutionsTemperature mL Correction per mL Used* FactorC N/20 or lesssolutionsN/10solutionsN/1solutionsN/20 or lesssolutionsN/10sol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAWWAB4082018LIQUIDPOLYALUMINUMCHLORIDEPDF

链接地址:http://www.mydoc123.com/p-433970.html