ANSI ATIS 0600030-2016 Line-Powering of Telecommunications Equipment on Outside Plant (OSP) Copper Twisted Pair Loops (Includes Access to Additional Content).pdf
《ANSI ATIS 0600030-2016 Line-Powering of Telecommunications Equipment on Outside Plant (OSP) Copper Twisted Pair Loops (Includes Access to Additional Content).pdf》由会员分享,可在线阅读,更多相关《ANSI ATIS 0600030-2016 Line-Powering of Telecommunications Equipment on Outside Plant (OSP) Copper Twisted Pair Loops (Includes Access to Additional Content).pdf(83页珍藏版)》请在麦多课文档分享上搜索。
1、 Confidential | Copyright 2016 IHS Markit Ltd Access to Additional Content For: ATIS-0600030, Dated: 11/2016 (Click here to view the publication) This Page is not part of the original publication This page has been added by IHS Markit as a convenience to the user in order to provide access to additi
2、onal content as authorized by the Copyright holder of this document Click the link(s) below to access the content and use normal procedures for downloading or opening the files. ATIS-0600030 Information contained in the above is the property of the Copyright holder and all Notice of Disclaimer their
3、 existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in n
4、o circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to th
5、e secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withd
6、raw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Notice of Disclaimer maximum voltage, power, and current limits in ANSI/ATIS-0600337 2; and additional electrical protection
7、information for line-powering schemes in ANSI/ATIS-0600332 1. These various standards define telecommunications line-powering voltage limits, power limits, and safety-related precautions. This document is an attempt to bring the requirements, standards, and precautions from all of these documents (a
8、nd relevant information from a few other sources) into a single consistent source, as well as provide user guidance on the engineering and application of line-powered equipment and cable. This standard is intended to define line-powering circuit characteristics (e.g., voltage windows, power maximums
9、) going forward, rather than cover all of the legacy systems. This does not preclude the use of other voltages and systems, but allows for interoperability of systems designed to this document. This standard also addresses performance of line-powering systems in fault conditions and provides manufac
10、turers, installers, and users of line power systems with a consistent fault condition testing and recording method. The fault current levels determined through this analysis can be compared to standards IEC 60479-1 9, Effects of Current on Human Beings and Livestock, Part 1- General Aspects and IEC
11、60479-2 10, Effects of Current on Human Beings and Livestock, ATIS-0600030.2016 2 Part 2- Special Aspects. 1.3 Test Conditions Unless otherwise noted, laboratory tests shall be conducted at an ambient temperature of 25C 5C. References 2The following standards contain provisions which, through refere
12、nce in this text, constitute provisions of this ATIS Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this ATIS Standard are encouraged to investigate the possibility of applying the most recent edition
13、s of the standards indicated below. 1 ANSI/ATIS-0600332, Electrical Protection of Network-Powered Broadband Facilities.12 ANSI/ATIS-0600337, Requirements for Maximum Voltage, Current, and Power Levels in Network-Powered Transport Systems.13 ANSI/IEEE C2, National Electrical Safety Code (NESC).24 ANS
14、I/NFPA 70, National Electrical Code (NEC).35 ASTM B193, Standard Test Method for Resistivity of Electrical Conductor Materials.46 ASTM B258, Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors.47 ASTM E1004,
15、Standard Test Method for Determining Electrical Conductivity Using the Electromagnetic (Eddy-Current) Method.48 CSA C22.2, General Requirements Canadian Electrical Code, Part II.59 IEC 60479-1, Effects of Current on Human Beings and Livestock, Part 1- General Aspects.610 IEC 60479-2, Effects of Curr
16、ent on Human Beings and Livestock, Part 2- Special Aspects.611 IEC/UL/CSA 62368-1, Ed. 2, Audio/Video, Information and Communication Technology Equipment- Part 1: Safety Requirements.612 IEC/UL/CSA 62368-3, Audio/Video, Information and Communication Technology Equipment- Safety- Part 3: Remote Power
17、 Feeding (in development).613 IEC 62602, Conductors of Insulated Cables Data for AWG and kcmil Sizes.614 IEEE 802.3, IEEE Standard for Ethernet.215 ITU-T K.50, Safe Limits of Operating Voltages and Currents for Telecommunications Systems. 16 NIOSH 98-131, Worker Deaths by Electrocution. 17 RUS RDUP
18、7 CFR 1775.390, PE-39-Omnicable. 18 RUS RDUP 7 CFR 1755.890, PE 89 Direct Burial. 19 Telcordia GR-421-CORE, Generic Requirements for Metallic Telecommunications Cables. 20 Telcordia GR-974-CORE, Telecommunications Line Protector Units (TLPUs). 1This document is available from the Alliance for Teleco
19、mmunications Industry Solutions, 1200 G Street N.W., Suite 500, Washington, DC 20005 at: . 2This document is available from the Institute of Electrical and Electronics Engineers (IEEE) at: . 3This document is available from the National Fire Protection Association (NFPA) at: . 4This document is avai
20、lable from ASTM International at: . 5This document is available from the CSA Group at: . 6This document is available from the International Electrotechnical Commission (IEC) at: . ATIS-0600030.2016 3 21 Telcordia GR-1089-CORE, Electromagnetic Compatibility and Electrical Safety - Generic Criteria fo
21、r Network Telecommunications Equipment. 22 Telcordia GR-1500-CORE, Powering Telecommunications Load Equipment (TLE) in Telecommunications Systems. 23 Telcordia GR-3164-CORE, Generic Requirements for Metallic Telecommunications Premises Wires. 24 UL/CSA 60950-1, Information Technology Equipment Safet
22、y General Requirements. 25 UL/CSA 60950-21, Information Technology Equipment Safety Remote Power Feeding. 26 UL-2391 Outline of Investigation for Equipment with Remote Feeding Telecommunication Circuits Intended for Backwards Compatibility in Legacy Telecommunication Equipment. Definitions, Acronyms
23、, therefore, a stranded wire will always have a slightly larger overall diameter than a solid wire of the same AWG due to the small air gaps between the strands. *Additional information can be found in IEC 62602 13. Circular mil: A circular mil refers to the cross sectional area of a circle 1 thousa
24、ndth of an inch in diameter. The largest wire sizes are often referred to in thousands of circular mils (kcmil); but even small wire gauges have an equivalent circular mil cross-sectional area. Class A1 Voltage: A telecommunications circuit whose dc operating voltage is between 30 and 200 V to groun
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIATIS06000302016LINEPOWERINGOFTELECOMMUNICATIONSEQUIPMENTONOUTSIDEPLANTOSPCOPPERTWISTEDPAIRLOOPSINCLUDESACCESSTOADDITIONALCONTENTPDF

链接地址:http://www.mydoc123.com/p-433471.html