ANSI ASTM F400-2010 Standard Consumer Safety Specification for Lighters《打火机用户安全性规范》.pdf
《ANSI ASTM F400-2010 Standard Consumer Safety Specification for Lighters《打火机用户安全性规范》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F400-2010 Standard Consumer Safety Specification for Lighters《打火机用户安全性规范》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F400 10 An American National StandardStandard Consumer Safety Specification forLighters1This standard is issued under the fixed designation F400; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revisio
2、n.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This consumer safety specification covers all flame-producing consumer products commonly known as cigarettelighters, pipe lighters, an
3、d cigar lighters and such similardevices as defined in 3.1.7. Matches are specifically excludedfrom this safety specification; flame-producing products in-tended solely for igniting apparatus other than cigars, pipes,and cigarettes are also specifically excluded from this safetyspecification. Lighte
4、rs are specifically not intended for use as acandle, flashlight, or for other uses requiring an extended burntime.1.2 This specification establishes requirements for lightersto ensure a reasonable degree of safety for normal use orreasonably foreseeable misuse of such lighters by users.1.3 Lighters,
5、 being flame-producing devices, can, as do allflame sources, present a potential hazard to the consumer. Thisspecification cannot eliminate all hazards, but is intended tominimize potential hazards of lighters to users.1.4 The values stated in SI units are to be regarded as thestandard. The values g
6、iven in parentheses are for informationonly.1.5 Disposable and novelty lighters as defined at 16 CFRPart 1210 are subject to the mandatory child resistancestandard found therein.1.6 The following precautionary caveat pertains only to thetest methods portion, Section 8, of this specification: Thissta
7、ndard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 Fe
8、deral Standard:216 CFR Part 1210 Safety Standard for Cigarette Lighters3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 burner valvecomponent of a gas lighter that controlsthe release of fuel.3.1.2 burner valve orificetip of the burner valve fromwhich fuel is released.3.1.3 fla
9、meresult of combustion of fuel that produces heatand often light which could be visible with the naked eye undernormal or subdued lighting conditions.3.1.4 flame heightlinear distance from the tip of thevisible flame to the top of the shield or, in the absence of ashield, from the tip of the visible
10、 flame to the top of the burnervalve orifice or to the bottom of the exposed wick.3.1.4.1 DiscussionFlame heights shall be measured inaccordance with 8.1.3.1.5 flaringvariance of flame height from the steady-stateflame condition.3.1.6 igniteto produce a flame with a lighter by activatingthe self-con
11、tained ignition and fuel release systems of thatlighter in the intended manner.3.1.7 lightermanually operated flame-producing deviceemploying a petrochemical derivative as a fuel. It is normallyused for deliberately igniting cigarettes, pipes, and cigars, andmay foreseeably be used to ignite materia
12、ls such as paper,wicks, candles, and lanterns.3.1.8 lighter, adjustablelighter that is received by theconsumer with a mechanism for the user to vary the height ofthe flame manually.3.1.9 lighter, automatic adjusting pipelighter designedand merchandised specifically for the purpose of lighting pipesa
13、nd characterized by an automatic increase in flame heightwhen tilted from an upright position.3.1.10 lighter, disposablelighter that is received by theuser with a supply of fuel and that is not intended to berefueled.3.1.11 lighter, fluidlighter that utilizes a hexane-type fluidsuch as petrol or nap
14、htha whose vapor pressure at 24C (75F)does not exceed a gage pressure of 34 kPa (5 psi).1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.02 onSafety Standards for Lighters.Current edition approved May 1, 2010
15、. Published June 2010. Originallyapproved in 1975. Last previous edition approved in 2004 as F400 04. DOI:10.1520/F0400-10.2Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.Copyright ASTM International, 100 Barr H
16、arbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.12 lighter, gaslighter that utilizes a butane, isobutane,propane, or other liquefied hydrocarbon mixture whose vaporpressure at 24C (75F) exceeds a gage pressure of 103 kPa (15psi).3.1.13 lighter, nonadjustablelighter that
17、 has a flameheight preset by the manufacturer and is not provided with amechanism to adjust the flame height.3.1.14 lighter, non-self-extinguishinglighter that, onceignited, does not require intentional or positive action by theuser to maintain a flame and requires a subsequent, deliberateuser actio
18、n to extinguish the flame.3.1.15 lighter, postmixing burnergas lighter in which fueland air is mixed at the point of combustion.3.1.16 lighter, premixing burnergas lighter in which fueland air is mixed before being supplied for combustion.3.1.17 lighter, refillablelighter that is intended to be refu
19、-eled either by decanting fuel from an external container or byinserting a new prepackaged fuel reservoir.3.1.18 lighter, self-extinguishinglighter that, once ignited,requires continuous intentional and positive action to maintaina flame and that is subsequently extinguished upon the termi-nation of
20、 such positive action.3.1.19 shieldstructure that totally or partially surroundsthe burner valve orifice of a gas lighter or the wick of a fluidlighter.3.1.20 sustained self-ignitionpropagation of a flame byother than deliberate manual operation, such as by dropping thelighter, so as to cause the ig
21、nition element to be activated andthe flame to continue to burn.3.1.21 spitting or sputteringflame phenomenon of a gaslighter wherein escape of nonevaporated or liquid fuel pro-duces a shower of burning liquid droplets which separate fromthe main flame.4. General Requirements4.1 Flame Generation (Ta
22、ble 1)In order to minimize thepossibility of inadvertent or self-ignition, lighters shall requirea deliberate manual operation to produce a flame. Theseoperations shall conform to at least one of the followingrequirements:4.1.1 A system such that positive action on the part of theconsumer is require
23、d to generate and maintain a flame.4.1.2 A system that requires two or more independentmotions to generate a flame.4.1.3 A system that requires an actuating force equal to orgreater than 15 N (3.4 lbf) to generate a flame (see Fig. X2.1or Fig. X2.2 for an example of test equipment).4.2 Flame Control
24、The maximum attainable flame heightfor lighters shall be limited with a setting or by product design,or both. For adjustable flame-height lighters, the maximumflame height that a user will obtain on first striking the lighterwithout adjustment shall also be limited. These limits shallcomply with the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF4002010STANDARDCONSUMERSAFETYSPECIFICATIONFORLIGHTERS 打火机 用户 安全性 规范 PDF

链接地址:http://www.mydoc123.com/p-433250.html