1、Designation: F2472 05 (Reapproved 2016) An American National StandardStandard Test Method forPerformance of Staff-Serve Hot Deli Cases1This standard is issued under the fixed designation F2472; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andperformance of staff-serve hot deli cases
3、with heated wellslocated within a fully or partially enclosed heated cavity. Thefood service operator can use this evaluation to select a staffserved hot deli case and understand its energy consumption andperformance.1.2 This test method is applicable to electric powered, hotdeli cases that have bee
4、n designed for staff service of preparedhot food items that are held in open hotel pans.1.3 The deli case can be evaluated with respect to thefollowing (where applicable):1.3.1 Energy input rate (10.2),1.3.2 Holding capacity (10.3),1.3.3 Holding temperature calibration (10.3),1.3.4 Preheat energy ra
5、te, (10.4),1.3.5 Idle energy rate (10.5), and1.3.6 Holding energy rate (10.6).1.4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.5 This test method may involve hazardous materials,operations, and equipment. This stan
6、dard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASH
7、RAE Document:2ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental Data2.2 NSF Standards:3NSF Listing Food Equipment and Related Components andMaterialNSF/ANSI 4 Commercial Cooking, Rethermalization andPowered Hot Food Holding and Transport Equipment3. Terminology3.1 Definitions:3.1.1
8、calibrated setting, ntemperature setting at which thelowest temperature of the food in the holding pans is at 142 62F (61 6 1C).3.1.2 capacity, namount of food product that can be heldin the units heated wells within standard 4-in. (102-mm) deepsteam table pans.3.1.3 energy input rate, npeak rate at
9、 which a deli caseconsumes energy (kW), typically reflected during preheat.3.1.4 holding energy, nenergy consumed by the deli caseas it is used to hold cooked food product under full loadconditions.3.1.5 holding energy rate, naverage rate of energy con-sumption (kW) during the holding energy tests.3
10、.1.6 idle energy rate, nrate of energy consumed (kW) bythe deli case while holding or maintaining the appliance at thethermostat set point without any food product.3.1.7 preheat energy, namount of energy consumed by thedeli case while preheating the appliance from ambient roomtemperature (73 6 3F (2
11、2 6 2C) to a temperature at thecalibrated setting.3.1.8 preheat rate, naverage rate (F/min) at which thedeli case is heated from ambient temperature (73 6 3F (22 62C) to holding temperature with the thermostat set to thecalibrated setting.3.1.9 preheat time, ntime required for the deli case toprehea
12、t from ambient room temperature (73 6 3F (22 62C) to the calibrated setting.3.1.10 staff-serve hot deli case, n(hereafter referred to asdeli case) an appliance, with heated wells located in a fully orpartially enclosed heated cavity, which is designed for the1This test method is under the jurisdicti
13、on of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Oct. 1, 2016. Published November 2016. Originallyapproved in 2005. Last previous edition approved in 2010 as F2472 05 (2010).DOI: 10.1
14、520/F2472-05R16.2Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae.org.3Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140, http:/www.nsf.org
15、.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1display and service of hot food product in standard hotel pans.Also known as hot food merchandisers, display merchandisersor hot display cases.3.1.11 uncertainty, nmeasure of systematic
16、 and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.4. Summary of Test Method4.1 The deli case is connected to the appropriate meteredenergy source, and energy input rate is determined to confirmthat the appliance is operating within 5 % of the name
17、plateenergy input rate.4.2 Capacity is determined by loading the deli cases heatedwells with 4-in. (100-mm) deep half-size steam table pans.4.3 The calibrated setting is determined by using pre-cooked food product (macaroni and cheese) in 4-in. (100-mm)deep half-size steam pans and setting controls
18、such that lowesttemperature in the center of the food pans is 142 6 2F (61 61C).4.4 The amount of energy and time required to preheat thedeli case to calibrated setting is determined.4.5 The idle energy rate is determined with the deli case setat calibrated setting and no food in the unit.4.6 The de
19、li case is used to hold 4-in. (100-mm) deephalf-size steam pans filled with hot food for 3 h. Foodtemperature and deli case energy consumption are monitoredduring this testing.5. Significance and Use5.1 The energy input rate is used to confirm that the delicase is operating properly prior to further
20、 testing.5.2 Capacity is used by food service operators to choose adeli case that matches their food holding requirements.5.3 Preheat energy and time can be useful to food serviceoperators to manage energy demands and to know how quicklythe deli case can be ready for operation.5.4 Holding energy rat
21、e and idle energy rate can be used bythe food service operator to estimate deli case energy consump-tion.6. Apparatus6.1 Analytical Balance Scale, for measuring weights up to20 lb (9 kg), with a resolution of 0.01 lb (0.005 kg) and anuncertainty of 0.01 lb (0.005 kg).6.2 Data Acquisition System, for
22、 measuring energy andtemperatures, capable of multiple channel displays updating atleast every 2 s.6.3 Thermocouple(s), industry standard type T or type Kthermocouple wire with a range of 0 to 250F (17 to 121C)and an uncertainty of 61F (60.5C).6.4 Thermocouple Probe, “fast response” type T or type K
23、thermocouple probe,116 in. (1.6 mm) or smaller diameter, witha 3-s or faster response time, capable of immersion with arange of 0 to 250F (17 to 121C) and an uncertainty of 61F(60.5C). The thermocouple probes active zone shall be at thetip of the probe.6.5 Watt-Hour Meter, for measuring the electric
24、al energyconsumption of a deli case, shall have a resolution of at least 10Wh and a maximum uncertainty no greater than 1.5 % of themeasured value for any demand greater than 100 W. For anydemand less than 100 W, the meter shall have a resolution of atleast 10 Wh and a maximum uncertainty no greater
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF24722005STANDARDTESTMETHODFORPERFORMANCEOFSTAFFSERVEHOTDELICASES 职工 供热 熟食 性能 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-433116.html