ANSI ASTM F1947-2010 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠式聚氯乙烯管(PVC)装进现有污水管和下水管道中的实施规程》.pdf
《ANSI ASTM F1947-2010 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠式聚氯乙烯管(PVC)装进现有污水管和下水管道中的实施规程》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1947-2010 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠式聚氯乙烯管(PVC)装进现有污水管和下水管道中的实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1947 10Standard Practice forInstallation of Folded Poly (Vinyl Chloride) (PVC) Pipe intoExisting Sewers and Conduits1This standard is issued under the fixed designation F1947; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice describes the procedures for the rehabili-tation of sewer lines and conduits (4 to 1
3、5 in. diameter) by theinsertion of a folded PVC pipe, which is heated, pressurized,and expanded against the interior surface of an existing pipewith either a mechanical rounding device or steam pressure.The finished PVC pipe will be continuous and conform to theexisting conduit. This rehabilitation
4、process can be used in avariety of nonpressure applications, such as: sanitary sewers,storm sewers, and process piping.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information on
5、lyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita
6、tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compo
7、unds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsF412 Terminology Relating to Plastic Piping SystemsF1417 Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure AirF1504 Speci
8、fication for Folded Poly(Vinyl Chloride) (PVC)Pipe for Existing Sewer and Conduit Rehabilitation2.2 NASSCO Standard:Recommended Specifications for Sewer Collection SystemRehabilitation33. Terminology3.1 Definitions Terminology used in this practice is inconformance with Terminology F412 and abbrevia
9、tions used inthis practice are in accordance with Terminology D1600,unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 containment tube, nan optional elastomeric materialplaced between the folded pipe and the existing pipe to protectthe folded pipe during insertion,
10、for containment of steamduring the installation process, and to provide a waterproofbarrier against infiltration, inflow, and standing water. This tuberemains within the pipe but provides no structural support.3.2.2 dimples (dimpling), nWhere a side connection meetsthe existing pipe, there is not ex
11、isting pipe support for the PVCpipe during expansion causing a point of thermoplastic pipeexpansion slightly beyond the existing pipe wall. This forma-tion of an external departure from the formed pipe wall istermed dimpling.3.2.3 folded pipe, nPVC pipe that has been manufacturedin a folded shape fo
12、r use in existing pipeline rehabilitation (seeFig. 1).3.2.4 formed pipe, nfolded pipe that has been inserted intoan existing sewer or conduit and expanded with heat, pressure,and, if applicable, a rounding device to conform to and take theshape of the existing pipe (see Fig. 1).3.2.5 insertion point
13、, nan existing manhole, existing ac-cess shaft, or an excavated pit that serves as the point ofentrance for the folded pipe into the existing pipe.1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchl
14、ess Plastic Pipeline Technology.Current edition approved Nov. 15, 2010. Published January 2011. Originallyapproved in 1998. Last previous edition approved in 2004 as F1947 04. DOI:10.1520/F1947-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service a
15、t serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.311521 Cronridge Drive, Suite J Owings Mills, MD 21117. www.nassco.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International
16、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.6 rounded field sample, na rounded field sample isformed when the folded pipe has been inserted into a mold pipeand expanded with heat and pressure to conform to the moldpipe.3.2.7 rounding device, na flexible,
17、 bullet-shaped device,which may be used to unfold and expand the folded pipe tightlyagainst the wall of the existing pipe.3.2.8 termination point, nan existing manhole, existingaccess shaft, or an excavated pit that serves as the point of exitof the folded pipe from the existing pipe.4. Significance
18、 and Use4.1 This practice is for use by designers and specifiers,regulatory agencies, owners, and inspection organizations whoare involved in the rehabilitation of non-pressure sewers andconduits.5. Materials5.1 The folded poly (vinyl chloride) (PVC) pipe shall be inaccordance with Specification F15
19、04.5.2 The folded pipe shall be spooled in a continuous lengthfor storage and shipping to the job site. Handling and storingshall be in accordance with the manufacturers publishedrecommendations.5.3 The optional containment tube should be an elastomericmaterial capable of containing the steam requir
20、ed to processthe folded pipe and serve as a protective waterproofing barrier.The containment tube shall be compatible with the PVCcompound, the folded pipe installation process, and the exist-ing pipe so as not to effect the properties of the finished pipe.6. Installation Recommendations6.1 Cleaning
21、 and Inspection:6.1.1 Prior to entering access areas such as manholes, andperforming inspection or cleaning operations, an evaluation ofthe atmosphere to determine the presence of toxic or flammablevapors or lack of oxygen must be undertaken in accordancewith local, state, or federal safety regulati
22、ons.6.1.2 Cleaning of PipelineInternal debris shall be re-moved from the existing pipeline. The pipeline should becleaned with hydraulically-powered equipment, high-velocityjet cleaners, or mechanically-powered equipment in accor-dance with NASSCO Recommended Specifications for SewerCollection Syste
23、m Rehabilitation.6.1.3 Inspection of PipelinesInspection of pipelines shallbe performed by experienced personnel trained in locatingbreaks, obstacles, and service connections by closed circuittelevision. The interior of the pipeline shall be inspectedcarefully to determine the location of any condit
24、ions that mayprevent proper installation of the folded pipe, such as protrud-ing service taps, collapsed or crushed pipe, out-of-roundness,significant line sags, and deflected joints. These conditionsshould be noted and corrected prior to installation.6.1.4 Line ObstructionsThe existing pipeline sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF19472010STANDARDPRACTICEFORINSTALLATIONOFFOLDEDPOLYVINYLCHLORIDEPVCPIPEINTOEXISTINGSEWERSANDCONDUITS

链接地址:http://www.mydoc123.com/p-432963.html