ANSI ASTM F1695-2003 Standard Test Method for Performance of Underfired Broilers《热底式烧烤器具性能的试验方法》.pdf
《ANSI ASTM F1695-2003 Standard Test Method for Performance of Underfired Broilers《热底式烧烤器具性能的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1695-2003 Standard Test Method for Performance of Underfired Broilers《热底式烧烤器具性能的试验方法》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1695 03 (Reapproved 2015) An American National StandardStandard Test Method forPerformance of Underfired Broilers1This standard is issued under the fixed designation F1695; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the evaluation of the energyconsumption and cooking performance of underfired
3、broilers.The food service operator can use this evaluation to select anunderfired broiler and understand its energy performance.1.2 This test method is applicable to gas and electricunderfired broilers.1.3 The underfired broiler can be evaluated with respect tothe following (where applicable):1.3.1
4、Energy input rate (see 10.2),1.3.2 Temperature distribution across the broiling area (see10.3),1.3.3 Preheat energy and time (see 10.4),1.3.4 Pilot energy rate, if applicable (see 10.5),1.3.5 Cooking energy rate (see 10.6), and1.3.6 Cooking energy efficiency and production capacity(see 10.7).1.4 The
5、 values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated
6、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelD3588 Practice
7、 for Calculating Heat Value, CompressibilityFactor, and Relative Density of Gaseous Fuels2.2 ANSI Standard:3ANSI Z83.11 American National Standard for Gas FoodService Equipment2.3 AOAC Documents:4AOAC Official Action 950.46 Air Drying to DetermineMoisture Content of Meat and Meat Products%AOAC Offic
8、ial Action 960.39 Fat (Crude) or Ether Extractin Meat2.4 ASHRAE Document:5ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental Data2.5 Other Document:6Development and Application of a Uniform Testing Proce-dure for Griddles, 1989Development and Validation of a Standard Test Method forU
9、nderfired Broilers, 19973. Terminology3.1 Definitions:3.1.1 cooking energy, nenergy consumed by the under-fired broiler as it is used to cook hamburger patties underheavy- and light-load conditions.3.1.2 cooking energy effciency, nquantity of energy im-parted to the hamburgers, expressed as a percen
10、tage of energyconsumed by the underfired broiler during the cooking event.3.1.3 cooking energy rate, naverage rate of energy con-sumption (Btu/h (kJ/h) or kW) during the cooking energyefficiency tests, with the underfired broiler set such that thebroiling area does not exceed 600F (315C) as measured
11、 by5-in. diameter steel disks.3.1.4 cook time, ntime required to cook fresh hamburgersas specified in 7.4 toa356 2 % weight loss during a cookingenergy efficiency test.1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subco
12、mmittee F26.06 onProductivity and Energy Protocol.Current edition approved March 1, 2015. Published May 2015. Originallyapproved in 1996. Last previous edition approved in 2008 as F1695 03 (2008).DOI: 10.1520/F1695-03R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
13、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from the Association o
14、f Official Analytical Chemists, 1111 N. 19thStreet, Arlington, VA 22209.5Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329.6Available from the Food Service Technology Center, 12949 Alcosta Blvd.,#101, Sa
15、n Roman, CA 94583.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.5 energy input rate, npeak rate at which an underfiredbroiler consumes energy (Btu/h (kJ/h) or kW).3.1.6 pilot energy rate, naverage rate of energy consump-tion (Bt
16、u/h (kJ/h) by an underfired broilers continuous pilot(if applicable).3.1.7 preheat energy, namount of energy consumed by theunderfired broiler while preheating the broiling area fromambient room temperature to 500F (260C).3.1.8 preheat rate, naverage rate (F/min (C/min) atwhich the broiling area tem
17、perature is heated from ambienttemperature to 500F (260C).3.1.9 preheat time, ntime required for the broiling area topreheat from ambient room temperature to 500F (260C).3.1.10 production capacity, nthe maximum rate (lb/h(kg/h) at which the broiler can cook fresh hamburgers asspecified in 7.4 toa356
18、 2 % weight loss.3.1.11 production rate, nthe average rate (lb/h (kg/h) atwhich the broiler brings the specified food product to aspecified “cooked” condition. It does not necessarily refer tothe maximum rate. The production rate varies with the amountof food being cooked.3.1.12 uncertainty, nmeasur
19、e of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.3.1.13 underfired broiler, nan appliance with a high tem-perature radiant heat source below a grate for cooking food,similar to the barbecue, also known as radiant or charbroilers.4.
20、 Summary of Test Method4.1 The underfired broiler is connected to the appropriatemetered energy source, and the energy input rate is determinedto confirm that the appliance is operating within 5 % of thenameplate energy input rate.4.2 The broiler grate is covered with 5-in. (127 mm)diameter metal di
21、sks and the temperature distribution of thebroiling area is determined by the disk temperatures with theunderfired broiler controls set to achieve maximum input rate.4.3 The amount of energy and time required to preheat thebroiling area to 500F (260C) is determined with the controlsset to achieve ma
22、ximum input rate.4.4 The pilot energy rate is determined, when applicable, forgas underfired broilers.4.5 The underfired broiler controls are set such that thebroiling area does not exceed a maximum temperature of600F (315C) and a cooking energy rate is established at thissetting.4.6 With the contro
23、ls set such that the broiling area does notexceed 600F (315C), the underfired broiler is used to cookthawed,13-lb (0.15-kg), 20 % fat, pure beef hamburger pattiesto a well-done condition (35 6 2 % weight loss, correspondingto an internal temperature of 175F (79C). Cooking energyefficiency is determi
24、ned for heavy- and light-load conditionsand production capacity is determined for heavy-load condi-tions.5. Significance and Use5.1 The energy input rate test is used to confirm that theunderfired broiler is operating properly prior to further testing.5.2 Temperature distribution of the broiling are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF16952003STANDARDTESTMETHODFORPERFORMANCEOFUNDERFIREDBROILERS 热底式 烧烤 器具 性能 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-432885.html