1、Designation: F1433 97 (Reapproved 2010)An American National StandardStandard Specification forMechanically Refrigerated Shipboard Air Conditioner1This standard is issued under the fixed designation F1433; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers self-contained mechanicallyrefrigerated air conditioners f
3、or shipboard use in air circula-tion, air cooling, and dehumidification.1.2 These air conditioners are intended for use in compart-ments and areas where central system air conditioning is notprovided.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are i
4、ncluded in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prio
5、r to use.2. Referenced Documents2.1 ASTM Standards:2A276 Specification for Stainless Steel Bars and ShapesA569/A569M Specification for Steel, Carbon (0.15 Maxi-mum, Percent), Hot-Rolled Sheet and Strip Commercial3B16/B16M Specification for Free-Cutting Brass Rod, Barand Shapes for Use in Screw Machi
6、nesB61 Specification for Steam or Valve Bronze CastingsB75 Specification for Seamless Copper TubeB148 Specification for Aluminum-Bronze Sand CastingsB209 Specification for Aluminum and Aluminum-AlloySheet and PlateD3951 Practice for Commercial Packaging2.2 Air-Conditioning and Refrigeration Institut
7、e (ARI):4ARI 210 Standard for Unitary Air-Conditioning Equipment2.3 American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE):5ASHRAE 15 Safety Code for Mechanical RefrigerationASHRAE 37 Methods of Testing for Rating Unitary Air-Conditioning and Heat Pump Equipment2.4 Americ
8、an Water Works Association (AWWA):6AWWA C504 Standard for Rubber-Seated Butterfly Valves2.5 National Electrical Manufacturers Association(NEMA):7NEMA MG 1 Motors and GeneratorsNEMA ICS 1 General Standards for Industrial Control andSystems2.6 Underwriters Laboratories, Inc. (UL):8UL 465 Standard for
9、Safety, Central Cooling, and AirConditioningUL 873 Standard for Safety Temperature-Indicating andRegulating Equipment2.7 Federal Specification:9FF-B-171 Bearings, Ball, Annular (General Purpose)2.8 Federal Regulations:9Code of Federal Regulations, Title 463. Terminology3.13.1.1 inspectionthe process
10、 of measuring, examining,testing, gaging, or otherwise comparing the unit with theapplicable requirements.3.1.2 lotall units of the same type, service, and sizeoffered for delivery at one time.3.2 Definitions of Terms Specific to This Standard:1This specification is under the jurisdiction of ASTM Co
11、mmittee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.11 onMachinery and Piping Systems.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1994. Last previous edition approved in 2004 as F1433 - 97 (2004).DOI: 10.1520/F1433-97R10
12、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical sta
13、ndard is referencedon www.astm.org.4Available from Air-Conditioning and Refrigeration Institute, 1501 WilsonBlvd., Arlington, VA 22209.5Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae
14、.org.6Available from American Water Works Association (AWWA), 6666 W. QuincyAve., Denver, CO 80235, http:/www.awwa.org.7Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.org.8Available from Underwriters Laboratories (U
15、L), 333 Pfingsten Rd., North-brook, IL 60062-2096, http:/.9Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United St
16、ates.3.2.1 air discharge plenuman enclosure (housing) con-taining guide vanes and a grill or louvers in the outlet openingfor directing the airflow.3.2.2 air handling/evaporator sectionan enclosed compo-nent consisting of an air filter, fan with drive motor, evaporator(cooling coil), refrigerant flo
17、w control, and condensate collec-tor and drain.3.2.3 condensing unitcontains refrigerating components,consisting of a compressor with a drive motor, condenser,receiver, operating and safety controls, and interconnectingpiping and wiring. The controls include a condenser waterregulating valve, high a
18、nd low refrigerant pressure switches,refrigerant relief device, and motor overload protection.3.2.4 cooling effectthe net room sensible cooling effect ofa unit is defined as the difference between the net total coolingeffect and the dehumidifying effect, expressed in watts. The nettotal cooling effe
19、ct is the total useful capacity of the unit forremoving heat from the space to be treated, expressed in watts.The net dehumidifying effect is the difference between themoisture content in kilograms per hour of the entering andleaving air, multiplied by 685, expressed in watts.4. Classification4.1 Th
20、e air conditioners should be of the following types,services, arrangements, and size as specified:Type I drip-proof protectedType II explosion-proof enclosedService 1 440-V 60-Hz alternating current (ac)Service 2 230-V direct current (dc)Service 3 115-V dcService 4 220-V 60-Hz alternating current (a
21、c)Arrangement A with air discharge plenumArrangement B without air discharge plenumSize 2 minimum cooling capacity 7000 WSize 3 minimum cooling capacity 10 500 WSize 5 minimum cooling capacity 17 500 WSize 712 minimum cooling capacity 26 000 W5. Ordering Information5.1 Orders for material under this
22、 specification shall includethe following:5.1.1 Title, number, and year of issue of this specification.5.1.2 Type, service, arrangement, and size of unit (see 4.1).5.1.3 Air discharge plenum required (see 6.1 and 6.5.10).5.1.4 Type of power supply for equipment and motors (see6.5.14.1 and 6.5.14.2).
23、5.1.5 When drip-proof protected or explosion-proof equip-ment is required (see 4.1, 6.5.14.1, and 6.5.14.2).5.1.6 When certification and test reports are required (see14.1).6. Materials and Manufacture6.1 GeneralAir conditioners covered by this specificationshall consist of a condensing unit section
24、, an air handling/evaporator section, and a motor controller. An air dischargeplenum may be included, if specified. These air conditionersshall be self-contained and shall perform as specified in thisspecification when connected to cooling water, drainage, andelectric power in accordance with UL 465
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF14331997STANDARDSPECIFICATIONFORMECHANICALLYREFRIGERATEDSHIPBOARDAIRCONDITIONER 机械 制冷 空调器 规范

链接地址:http://www.mydoc123.com/p-432830.html