ANSI ASTM E1776-2016 Standard Guide for Development of Fire-Risk-Assessment Standards.pdf
《ANSI ASTM E1776-2016 Standard Guide for Development of Fire-Risk-Assessment Standards.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E1776-2016 Standard Guide for Development of Fire-Risk-Assessment Standards.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1776 16 An American National StandardStandard Guide forDevelopment of Fire-Risk-Assessment Standards1This standard is issued under the fixed designation E1776; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the development of fire-risk-assessment standards.1.2 This guide is directed toward development o
3、f standardsthat will provide procedures for assessing fire risks harmful topeople, property, or the environment.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate saf
4、ety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This standard is used to establish a means of combiningthe potential for harm in fire scenarios with the probabilities ofoccurrence of those scenarios. Assessment of fire risk using thisstandard depe
5、nds upon many factors, including the manner inwhich the user selects scenarios and uses them to represent allscenarios relevant to the application. This standard cannot beused to assess fire risk if any specifications are different fromthose contained in the standard.1.5 This fire standard cannot be
6、 used to provide quantitativemeasures.2. Referenced Documents2.1 ASTM Standards:2E176 Terminology of Fire StandardsE1546 Guide for Development of Fire-Hazard-AssessmentStandards2.2 Other Documents:SFPE Engineering Guide to Performance-Based FireProtection, Society of Fire Protection Engineers andNFP
7、A, Quincy, MA, 20003ISO 13943 Fire Safety Vocabulary43. Terminology3.1 DefinitionsSee E176, Terminology of Fire Standardsand ISO 13943, Fire Safety Vocabulary. In case of conflict,the definitions in Terminology E176 shall prevailE176.4. Significance and Use4.1 This guide is intended for use by those
8、 undertaking thedevelopment of fire-risk-assessment standards. Such standardsare expected to be useful to manufacturers, architects, specifi-cation writers, and authorities having jurisdiction.4.2 As a guide, this document provides information on anapproach to the development of a fire-risk-assessme
9、nt stan-dard; fixed procedures are not established. Limitations of data,available tests and models, and scientific knowledge canconstitute significant constraints on the fire-risk-assessmentprocedure and associated standard.4.3 While the focus of this guide is on developing fire-risk-assessment stan
10、dards for products, the general concepts pre-sented also can be applied to processes, activities, occupancies,and buildings.5. Key Elements5.1 This guide uses as its key elements the following:5.1.1 The purpose of a fire-risk-assessment standard is toprovide a standardized procedure for assembling a
11、 compilationof information relevant to the fire risk of a product underspecific conditions of use.5.1.2 The information assembled shall be relevant to thepurpose of assessing the fire risk of the specific designatedproduct within the range of all relevant fire scenarios.5.1.3 The information assembl
12、ed shall be explicit and quan-titative. It shall provide a sufficiently thorough examination ofthe products fire risk under the conditions defined by the scopeof the specific standard so as to permit valid choices anddecisions with respect to the fire risk of that product.5.1.4 A persuasive scientif
13、ic case must be made in thedocumentation of a specific fire-risk-assessment standard thatthe procedures, data, and risk measures specified by thestandard will address questions about a products fire risk withsufficient accuracy and validity that a more thorough assess-ment procedure would not materi
14、ally alter any decisions thatare to be made based on the standard. If such a case cannot bemade for all products to be addressed, then the risk assessment1This guide is under the jurisdiction ofASTM Committee E05 on Fire Standardsand is the direct responsibility of Subcommittee E05.33 on Fire Safety
15、 Engineering.Current edition approved June 1, 2016. Published July 2016. Originallypublished in 1996. Last previous edition approved in 2007 as E1776 13. DOI:10.1520/E1776-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
16、 Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from NFPA, 1 Batterymarch Park, Quincy, MA 021697471.4Available from International Organization for Standardization (ISO), 1 rue deVaremb, Case postale 56, CH-1211, Geneva 20,
17、 Switzerland, http:/www.iso.ch.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1shall specify those conditions under which a more thoroughfire-risk-assessment procedure is to be used.5.1.5 The absence of a data source, test method, or
18、calcu-lation procedure of sufficient scope and proven validity tosupport the needs of a particular fire-risk-assessment proceduredoes not, by itself, provide a sufficient justification for the useof a data source, test method, or calculation procedure of lesserscope or unproven validity. It is recog
19、nized that fire-riskassessments of such products may need to be performed in anyevent, using relevant nonstandardized procedures. When suchnonstandardized or unvalidated procedures are used, the detailsshall be included to such an extent that the procedures becomestandardized only for use within the
20、 specified fire-risk-assessment procedure through final publication of the fire-risk-assessment standard document.5.1.6 Among the possible significant outcomes of a fire-riskassessment are a revelation that a product produces either anincrease, no increase, or a decrease in fire risk on some or allr
21、isk measures and for all or some of the scenarios specified bythe standard relative to another product or relative to baselinerisk values for those measures and scenarios. These baselinevalues may or may not be derived from fire-risk assessment ofproducts already in use. However, when the product is
22、 pro-posed for an existing use, the appropriate baseline for com-parison is existing products having the same use. For example,if a products risk is uniformly rated greater than the referencevalues on all comparisons specified by the standard, then theoverall fire-risk assessment of the product will
23、 be greater thanthe fire risk of the baseline (or product in use).5.1.7 If the assessment shows that the product is notuniformly rated higher than, equivalent to, or less than theother product(s) or the baseline for all risk measures, andreflecting all scenarios specified by the standard, then theim
24、plications of the fire risk assessment for product evaluationwill not be clear without the development of appropriatedecision rules. Such rules would determine the overall risk,giving appropriate weighting to each risk measure.6. Relationship Between Fire Hazard and Fire Risk6.1 It is important to d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME17762016STANDARDGUIDEFORDEVELOPMENTOFFIRERISKASSESSMENTSTANDARDSPDF

链接地址:http://www.mydoc123.com/p-432568.html