ANSI ASTM E177-2014 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods.pdf
《ANSI ASTM E177-2014 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E177-2014 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E177 14 An American National StandardStandard Practice forUse of the Terms Precision and Bias in ASTM Test Methods1This standard is issued under the fixed designation E177; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 The purpose of th
3、is practice is to present conceptsnecessary to the understanding of the terms “precision” and“bias” as used in quantitative test methods. This practice alsodescribes methods of expressing precision and bias and, in afinal section, gives examples of how statements on precisionand bias may be written
4、for ASTM test methods.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior
5、 to use.2. Referenced Documents2.1 ASTM Standards:2E456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1488 Guide for Statistical Procedures to Use in Developingand Applying Test MethodsE2282 Guide for De
6、fining the Test Result of a Test MethodE2586 Practice for Calculating and Using Basic StatisticsE2587 Practice for Use of Control Charts in StatisticalProcess Control3. Terminology3.1 DefinitionsTerminology E456 provides a more exten-sive list of terms in E11 standards.3.1.1 accepted reference value
7、, na value that serves as anagreed-upon reference for comparison, and which is derivedas: (1) a theoretical or established value, based on scientificprinciples, (2) an assigned or certified value, based on experi-mental work of some national or international organization, or(3) a consensus or certif
8、ied value, based on collaborativeexperimental work under the auspices of a scientific orengineering group.3.1.1.1 DiscussionA national or internationalorganization, referred to in 3.1.1 (2), generally maintainsmeasurement standards to which the reference values obtainedare traceable.3.1.2 accuracy,
9、nthe closeness of agreement between atest result and an accepted reference value.3.1.2.1 DiscussionThe term accuracy, when applied to aset of test results, involves a combination of a randomcomponent and of a common systematic error or bias compo-nent.3.1.3 bias, nthe difference between the expectat
10、ion of thetest results and an accepted reference value.3.1.3.1 DiscussionBias is the total systematic error ascontrasted to random error. There may be one or moresystematic error components contributing to the bias. A largersystematic difference from the accepted reference value isreflected by a lar
11、ger bias value.3.1.4 characteristic, na property of items in a sample orpopulation which, when measured, counted or otherwiseobserved, helps to distinguish between the items. E22823.1.5 coeffcient of variation, CV, nfor a nonnegativecharacteristic, the ratio of the standard deviation to the meanfor
12、a population or sample. E25863.1.6 intermediate precision, nthe closeness of agreementbetween test results obtained under specified intermediateprecision conditions.3.1.6.1 DiscussionThe specific measure and the specificconditions must be specified for each intermediate measure ofprecision; thus, “s
13、tandard deviation of test results amongoperators in a laboratory,” or “day-to-day standard deviationwithin a laboratory for the same operator.”3.1.6.2 DiscussionBecause the training of operators, theagreement of different pieces of equipment in the samelaboratory and the variation of environmental c
14、onditions withlonger time intervals all depend on the degree of within-laboratory control, the intermediate measures of precision arelikely to vary appreciably from laboratory to laboratory. Thus,intermediate precisions may be more characteristic of indi-vidual laboratories than of the test method.1
15、This practice is under the jurisdiction of ASTM Committee E11 on Quality andStatistics and is the direct responsibility of Subcommittee E11.20 on Test MethodEvaluation and Quality Control.Current edition approved May 1, 2014. Published May 2014. Originallyapproved in 1961. Last previous edition appr
16、oved in 2013 as E177 13. DOI:10.1520/E0177-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM
17、International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.7 intermediate precision conditions, nconditions un-der which test results are obtained with the same test methodusing test units or test specimens taken at random from a singlequantity of material
18、 that is as nearly homogeneous as possible,and with changing conditions such as operator, measuringequipment, location within the laboratory, and time.3.1.8 observation, nthe process of obtaining informationregarding the presence or absence of an attribute of a testspecimen, or of making a reading o
19、n a characteristic ordimension of a test specimen. E22823.1.9 observed value, nthe value obtained by making anobservation. E22823.1.10 precision, nthe closeness of agreement betweenindependent test results obtained under stipulated conditions.3.1.10.1 DiscussionPrecision depends on random errorsand
20、does not relate to the accepted reference value.3.1.10.2 DiscussionThe measure of precision usually isexpressed in terms of imprecision and computed as a standarddeviation of the test results. Less precision is reflected by alarger standard deviation.3.1.10.3 Discussion“Independent test results” mea
21、ns re-sults obtained in a manner not influenced by any previousresult on the same or similar test object. Quantitative measuresof precision depend critically on the stipulated conditions.Repeatability and reproducibility conditions are particular setsof extreme stipulated conditions.3.1.11 repeatabi
22、lity, nprecision under repeatability condi-tions.3.1.11.1 DiscussionRepeatability is one of the concepts orcategories of the precision of a test method.3.1.11.2 DiscussionMeasures of repeatability defined inthis compilation are repeatability standard deviation and re-peatability limit.3.1.12 repeata
23、bility conditions, nconditions where inde-pendent test results are obtained with the same method onidentical test items in the same laboratory by the same operatorusing the same equipment within short intervals of time.3.1.12.1 DiscussionSee precision, The “same operator,same equipment” requirement
24、means that for a particular stepin the measurement process, the same combination of operatorand equipment is used for every test result. Thus, one operatormay prepare the test specimens, a second measure the dimen-sions and a third measure the mass in a test method fordetermining density.3.1.12.2 Di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME1772014STANDARDPRACTICEFORUSEOFTHETERMSPRECISIONANDBIASINASTMTESTMETHODSPDF

链接地址:http://www.mydoc123.com/p-432567.html