《ANSI ASTM E1663-2003 Standard Classification for Serviceability of an Office Facility for Typical Office Information Technology《办公设备对于典型办公室信息技术的适用性分类》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E1663-2003 Standard Classification for Serviceability of an Office Facility for Typical Office Information Technology《办公设备对于典型办公室信息技术的适用性分类》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1663 03 (Reapproved 2010) An American National StandardStandard Classification forServiceability of an Office Facility for Typical OfficeInformation Technology1, 2This standard is issued under the fixed designation E1663; the number immediately following the designation indicates the y
2、ear oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classi
3、fyingan aspect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments for performance to support typical office equipment forinformation technology.1.2 Within that aspect of serviceability, each pair of scales,shown in Figs. 1
4、-6, are for classifying one topic of serviceabil-ity. Each paragraph in an Occupant Requirement Scale (seeFigs. 1-6) summarizes one level of serviceability on that topic,which occupants might require. The matching entry in theFacility Rating Scale (see Figs. 1-6) is a translation of therequirement i
5、nto a description of certain features of a facilitywhich, taken in combination, indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-6)are indicative and not comprehensive. They are for quickscanning to estimate a
6、pproximately, quickly, and economically,how well an office facility is likely to meet the needs of one oranother type of occupant group over time. The entries are notfor measuring, knowing, or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level of
7、serviceability of an existing facility. It can also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be r
8、ated at a certain level of serviceability but does not statehow to conduct a serviceability rating nor how to assign aserviceability score. That information is found in PracticeE1334. The scales in this classification are complimentary to,and compatible with, Practices E1334 and E1679. Each re-quire
9、s the other.2. Referenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Building orBuilding-Related Facility (Withdrawn 2013)4E1679 Practice for Setting the Requirements for the Service-ability of a Building or Building-Relat
10、ed Facility, and forDetermining What Serviceability is Provided or Proposed2.2 ISO Document:5ISO 6240 International Standard, Performance Standards inBuildingContents and Presentation2.3 Other Document:5ANSI/TIA/EIA-569A Commercial Building Standards forTelecommunications Pathways and Spaces3. Termi
11、nology3.1 Definitions:3.1.1 facilitya physical setting used to serve a specificpurpose.3.1.1.1 DiscussionA facility may be within a building, awhole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the phys
12、ical object and its use (seeTerminology E631).3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orrequired to be used.3.1.2.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components
13、andmaterials and their interactions, such as acoustical,1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved April 1, 2010. Published July 2010
14、. Originallyapproved in 1995. Last previous edition approved in 2003 as E1663 03. DOI:10.1520/E1663-03R10.2Portions of this document are based on material originally prepared by theInternational Centre for Facilities (ICF) and 1993 by ICF and Minister of PublicWorks and Government Services Canada. T
15、heir cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM w
16、ebsite.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
17、n, PA 19428-2959. United States1FIG. 1 Scale A.5.1 for Office Computers and Related EquipmentE1663 03 (2010)2FIG. 1 Scale A.5.1 for Office Computers and Related Equipment (continued)E1663 03 (2010)3FIG. 2 Scale A.5.2 for Power at the WorkplaceE1663 03 (2010)4FIG. 2 Scale A.5.2 for Power at the Workp
18、lace (continued)E1663 03 (2010)5FIG. 3 Scale A.5.3 for Building PowerE1663 03 (2010)6hydrothermal, air purity, and economic; and of the relativeimportance of each performance requirement (see TerminologyE631).3.1.3 offcea place, such as a room, suite, or building, inwhich business, clerical, or prof
19、essional activities are con-ducted (see Terminology E631).3.1.4 For standard definitions of additional terms applicableto this classification, see Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 conduit capacitya conduit is considered full whenthe internal area occupied by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME16632003STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORTYPICALOFFICEINFORMATIONTECHNOLOGY

链接地址:http://www.mydoc123.com/p-432543.html