ANSI ASTM E1661 REV A-1995 Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness.pdf
《ANSI ASTM E1661 REV A-1995 Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E1661 REV A-1995 Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1661 95a (Reapproved 2012) An American National StandardStandard Classification forServiceability of an Office Facility for Meetings and GroupEffectiveness1,2This standard is issued under the fixed designation E1661; the number immediately following the designation indicates the year o
2、foriginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classifying
3、an aspect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments to enable work groups or project groups to functioneffectively and productively.1.2 Within that aspect of serviceability, each pair of scales,shown in Figs. 1-4,
4、 are for classifying one topic of serviceabil-ity. Each paragraph in an Occupant Requirement Scale (seeFigs. 1-4) summarizes one level of serviceability on that topic,which occupants might require. The matching entry in theFacility Rating Scale (see Figs. 1-4) is a translation of therequirement into
5、 a description of certain features of a facilitywhich, taken in combination, indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-4)are indicative and not comprehensive. They are for quickscanning to estimate appr
6、oximately, quickly, and economically,how well an office facility is likely to meet the needs of one oranother type of occupant group over time. The entries are notfor measuring, knowing, or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level ofser
7、viceability of an existing facility. It can also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rate
8、d at a certain level of serviceability but does not statehow to conduct a serviceability rating nor how to assign aserviceability score. That information is found in PracticeE1334. The scales in this classification are complimentary toand compatible with Practice E1334. Each requires the other.2. Re
9、ferenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Building orBuilding-Related Facility (Withdrawn 2013)4E1679 Practice for Setting the Requirements for the Service-ability of a Building or Building-Related Facility, and
10、forDetermining What Serviceability is Provided or Proposed2.2 ISO Document:5ISO 6240 International Standard, Performance Standards inBuildingContents and Presentation3. Terminology3.1 Definitions:3.1.1 facilitya physical setting used to serve a specificpurpose. E6313.1.1.1 DiscussionA facility may b
11、e within a building, awhole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it
12、is designed, used, orrequired to be used. E6313.1.2.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components andmaterials and their interactions, such as acoustical,hydrothermal, air purity, and economic; and of the relativeimportance of each perf
13、ormance requirement.3.1.3 offcea place, such as a room, suite, or building, inwhich business, clerical or professional activities areconducted. E6311This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25o
14、n Whole Buildings and Facilities.Current edition approved April 1, 2012. Published May 2012. Originallyapproved in 1995. Last previous edition approved in 2005 as E1661 95a (2005).DOI: 10.1520/E1661-95AR12.2Portions of this document are based on material originally prepared by theInternational Centr
15、e for Facilities (ICF) and 1993 by ICF and Minister of PublicWorks and Government Services Canada. Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
16、 Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, h
17、ttp:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1FIG. 1 Scale A.2.1 for Meeting and Conference RoomsE1661 95a (2012)2FIG. 1 Scale A.2.1 for Meeting and Conference Rooms (continued)E1661 95a (2012)3FIG. 1 Scale A.2.1 f
18、or Meeting and Conference Rooms (continued)E1661 95a (2012)4FIG. 2 Scale A.2.2 for Informal Meetings and InteractionE1661 95a (2012)5FIG. 2 Scale A.2.2 for Informal Meetings and Interaction (continued)E1661 95a (2012)6FIG. 3 Scale A.2.3 for Group Layout and TerritoryE1661 95a (2012)7FIG. 3 Scale A.2
19、.3 for Group Layout and Territory (continued)E1661 95a (2012)8FIG. 4 Scale A.2.4 for Group WorkroomsE1661 95a (2012)9FIG. 4 Scale A.2.4 for Group Workrooms (continued)E1661 95a (2012)103.1.4 For standard definitions of additional terms applicableto this classification, see Terminology E631.3.2 Defin
20、itions of Terms Specific to This Standard:3.2.1 workgrouppeople who work closely together toachieve a defined task, project, or objective, which is oftenbased in a single workroom.3.2.1.1 DiscussionThe size of a workgroup typicallyranges from four to twelve people. Duration of the project,task, or o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME1661REVA1995STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORMEETINGSANDGROUPEFFECTIVENESSPDF

链接地址:http://www.mydoc123.com/p-432541.html