ANSI ASTM E162-2016 Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.pdf
《ANSI ASTM E162-2016 Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E162-2016 Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E162 16 An American National StandardStandard Test Method forSurface Flammability of Materials Using a Radiant HeatEnergy Source1This standard is issued under the fixed designation E162; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 Thi
3、s fire-test-response standard describes the measure-ment of surface flammability of materials. It is not intended foruse as a basis of ratings for building code purposes (seeAppendix X1).1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are math
4、ematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard measures and describes the response ofmaterials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate allfactors required for fi
5、re hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
6、health practices and determine the applica-bility of regulatory limitations prior to use.1.5 Fire testing of products and materials is inherentlyhazardous, and adequate safeguards for personnel and propertyshall be employed in conducting these tests. This test methodmay involve hazardous materials,
7、operations, and equipment.Specific information about hazard is given in Section .NOTE 1There is no similar or equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:2C1186 Specification for Flat Fiber-Cement SheetsC1288 Specification for Discrete Non-Asbestos Fiber-Cement Interior Substra
8、te SheetsD3675 Test Method for Surface Flammability of FlexibleCellular Materials Using a Radiant Heat Energy SourceE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE176 Terminology of Fire StandardsE1546 Guide for Development of Fire-Hazard-AssessmentStandards2.2 ISO Standard
9、s3ISO 13943 Fire SafetyVocabulary3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to the terminology contained in TerminologyE176 and ISO 13943. In case of conflict, the definitions givenin Terminology E176 shall prevail.3.2 Definitions of Terms Specific to This S
10、tandard:3.2.1 flashing, nflame fronts of 3 seconds or less induration.3.2.1.1 DiscussionAll flame fronts, however temporary,are to be taken into account.3.2.2 radiant panel index, Is,nthe radiant panel index isthe product of the flame spread factor, Fs, and the heatevolution factor, Q.4. Summary of
11、Test Method4.1 This test method of measuring surface flammability ofmaterials employs a radiant heat source consisting of a 12 by18-in. (305 by 457-mm) panel, in front of which an inclined 6by 18-in. (152 by 457 mm) specimen of the material is placed.The orientation of the specimen is such that igni
12、tion is forcednear its upper edge and the flame front progresses downward.4.2 A factor derived from the rate of progress of the flamefront and another derived from the rate of heat liberated by thematerial under test are combined to provide a radiant panelindex.1This test method is under the jurisdi
13、ction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.22 on SurfaceBurning.Current edition approved Dec. 15, 2016. Published January 2017. Originallyapproved in 1960. Last previous edition approved in 2015 as E162 15b. DOI:10.1520/E0162-16.2For referenced
14、ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Organization for Standardization (ISO), 1, ch.
15、dela Voie-Creuse, Case postale 56, CH-1211, Geneva 20, Switzerland, http:/www.iso.ch.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on
16、standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15. Significance and Use5.1 This test method provides a laboratory test procedure for
17、measuring and comparing the surface flammability of materialswhen exposed to a prescribed level of radiant heat energy. It isintended for use in measurements of the surface flammabilityof materials exposed to fire. The test is conducted using smallspecimens that are representative, to the extent pos
18、sible, of thematerial or assembly being evaluated. (Example: in terms oftheir thickness, layering, and any potential substrate.)5.2 The rate at which flames will travel along surfacesdepends upon the physical and thermal properties of thematerial, product or assembly under test, the specimen mount-i
19、ng method and orientation, the type and level of fire or heatexposure, the availability of air, and properties of the surround-ing enclosure.45.3 In this procedure, the specimens are subjected to one ormore specific sets of laboratory fire test conditions. If differenttest conditions are substituted
20、 or the end-use conditions arechanged, it is not always possible by or from this test to predictchanges in the fire-test-response characteristics measured.Therefore, the results are valid only for the fire test exposureconditions described in this procedure.5.4 If the test results obtained by this t
21、est method are to beconsidered as part of an overall assessment of fire hazard in abuilding or structure, then the example criteria, concepts andprocedures incorporated into Guide E1546 shall be taken intoconsideration.6. Apparatus6.1 The apparatus shall be as shown in Fig. 1 and includethe followin
22、g:6.1.1 Radiant Panel with Air and Gas SupplyThe radiantpanel shall consist of a porous refractory material verticallymounted in a cast iron frame, exposing a radiating surface of12 by 18 in. (305 by 457 mm) and shall be capable of operatingat temperatures up to 1500F (815C). The panel shall beequip
23、ped (see Fig. 1) with a venturi-type aspirator for mixinggas and air at approximately atmospheric pressure; a centrifu-gal blower, or equivalent, capable of providing 1200 ft3/h (9.4L/s) air at a pressure of 2.8 in. of water (700 Pa); an air filterto prevent dust from obstructing the panel pores; a
24、pressureregulator and a control and shut-off valve for the gas supply.6.1.2 Specimen HolderThe specimen holder shall con-form in shape and dimension to Fig. 2 and be constructed fromheat-resistant chromium steel. Observation marks shall be filedon the surface of the specimen holder to correspond wit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME1622016STANDARDTESTMETHODFORSURFACEFLAMMABILITYOFMATERIALSUSINGARADIANTHEATENERGYSOURCEPDF

链接地址:http://www.mydoc123.com/p-432538.html