ANSI ASTM E108-2017 Standard Test Methods for Fire Tests of Roof Coverings.pdf
《ANSI ASTM E108-2017 Standard Test Methods for Fire Tests of Roof Coverings.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM E108-2017 Standard Test Methods for Fire Tests of Roof Coverings.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E108 17 An American National StandardStandard Test Methods forFire Tests of Roof Coverings1This standard is issued under the fixed designation E108; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This fire-test-response standard covers
3、the measurementof the relative fire characteristics of roof coverings exposed tosimulated fire sources originating outside the building. It isapplicable to roof coverings intended for installation on eithercombustible or noncombustible roof decks when applied asintended for use. The following test m
4、ethods are included:1.1.1 Intermittent flame exposure test.1.1.2 Spread of flame test.1.1.3 Burning brand test.1.1.4 Flying brand test.1.1.5 Rain test.1.2 Three classes of fire test exposure are described:1.2.1 Class A Tests are applicable to roof coverings that areexpected to be effective against s
5、evere fire exposure, afford ahigh degree of fire protection to the roof deck, do not slip fromposition, and are not expected to present a flying brand hazard.1.2.2 Class B Tests are applicable to roof coverings that areexpected to be effective against moderate fire exposure, afforda moderate degree
6、of fire protection to the roof deck, do notslip from position, and are not expected to present a flyingbrand hazard.1.2.3 Class C Tests are applicable to roof coverings that areeffective against light fire exposure, afford a light degree of fireprotection to the roof deck, do not slip from position,
7、 and arenot expected to present a flying brand hazard.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard is used to me
8、asure and describe theresponse of materials, products, or assemblies to heat andflame under controlled laboratory conditions, but does not byitself incorporate all factors required for fire hazard or fire riskassessment of the materials, products or assemblies underactual fire conditions.1.5 This st
9、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.6 Fire testing is inhere
10、ntly hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.7 The text of this standard references notes and footnotesthat provide explanatory information. These notes andfootnotes, excluding those in tables and figures, shall not beconsidered as requ
11、irements of this standard.2. Referenced Documents2.1 ASTM Standards:2D225 Specification for Asphalt Shingles (Organic Felt) Sur-faced With Mineral Granules (Withdrawn 2012)3D226 Specification for Asphalt-Saturated Organic Felt Usedin Roofing and WaterproofingD227 Specification for Coal-Tar-Saturated
12、 Organic FeltUsed in Roofing and WaterproofingD312 Specification for Asphalt Used in RoofingD450 Specification for Coal-Tar Pitch Used in Roofing,Dampproofing, and WaterproofingD1227 Specification for Emulsified Asphalt Used as a Pro-tective Coating for RoofingD2178 Specification for Asphalt Glass F
13、elt Used in Roofingand WaterproofingD2626 Specification for Asphalt-Saturated and Coated Or-ganic Felt Base Sheet Used in RoofingD2898 Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingD3018 Specification for Class A Asphalt Shingles Surfacedwith Mineral Granules1The
14、se test methods are under the jurisdiction ofASTM Committee E05 on FireStandards and are the direct responsibility of Subcommittee E05.14 on External FireExposures.Current edition approved Feb. 1, 2017. Published March 2017. Originallyapproved in 1955. Last previous edition approved in 2016 as E108
15、161. DOI:10.1520/E0108-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this
16、historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationa
17、lly recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1D3158 Specification for Asphalt Saturated and Coated Or
18、-ganic Felt Used in Roofing (Withdrawn 1983)3D3378 Specification for Asphalt-Saturated and Coated As-bestos Felt Base Sheet Used in Roofing (Withdrawn1985)3D3462 Specification for Asphalt Shingles Made from GlassFelt and Surfaced with Mineral GranulesD4442 Test Methods for Direct Moisture Content Me
19、asure-ment of Wood and Wood-Based MaterialsD4444 Test Method for Laboratory Standardization andCalibration of Hand-Held Moisture Meters2.2 UL Standards:UL 55A Materials for Built-Up Roof Coverings4UL790 Tests for Fire Resistance of Roof Covering Materi-als42.3 NFPA Standards:NFPA 256 Tests of Roof C
20、overings (Withdrawn 2008)52.4 NIST Standards:Department of Commerce (DOC) Voluntary Product Stan-dard PS-1 Structural PlywoodDepartment of Commerce (DOC) Voluntary Product Stan-dard PS-2 Performance Standard for Wood-basedStructural-use Panels3. Terminology3.1 Definitions:3.1.1 significant lateral s
21、preadsurface flaming beyond1-ft. from the lead edge, extending outward to both lateraledges of the test deck assembly or to both inner edges of metalbatten strips, if used, along the side edges of the test deckassembly.3.1.2 sustained flamingany flaming which continues un-interrupted for 5 seconds o
22、r more.3.1.3 prepared roof coveringproducts consisting ofshingles, tiles, panels or rolled materials that are typically usedfor steep slope roof applications which are applied directly tothe roof deck (usually with one or more layers of underlaymentand with or without battens) in accordance with ins
23、tallationinstructions supplied with the products.4. Significance and Use4.1 The test methods described herein are intended toprovide a basis for relative comparison of roof coverings. Thetest methods include simulated fire exposure to the outside ofthe roof coverings, and, where applicable, a determ
24、ination as towhether the fire performance characteristics of the roof cover-ings will be adversely affected by prolonged exposure to rain.4.2 These test methods measure the surface spread of flameand the ability of the roof covering material or system to resistfire penetration from the exterior to t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME1082017STANDARDTESTMETHODSFORFIRETESTSOFROOFCOVERINGSPDF

链接地址:http://www.mydoc123.com/p-432511.html